THERMOROSSI BOSKY SQUARE 30 Installation, Use And Maintenance Manual

THERMOROSSI BOSKY SQUARE 30 Installation, Use And Maintenance Manual

Advertisement

Quick Links

BOSKY SQUARE 30 – F30
BOSKY SQUARE 30 – F30 (READY TO START)
ITA - MANUALE DI INSTALLAZIONE, USO E MANUTENZIONE.
FRA - MANUEL D'INSTALLATION, D'UTILISATION ET D'ENTRETIEN.
ENG - INSTALLATION, USE AND MAINTENANCE GUIDE.
DEU - INSTALLATIONS-, BETRIEBS- UND WARTUNGSANLEITUNG.
ESP - MANUAL DE INSTALACIÓN USO Y MANTENIMIENTO.
ITA – Informazioni importanti per la sicurezza ed il corretto funzionamento.
FRA - À lire impérativement! Informations importantes pour la sécurité et le bon fonctionnement.
ENG - Must read! Important information for safety and correct operation.
DEU - Unbedingt lesen! Wichtige Informationen zur Sicherheit und zum sicheren Betrieb.
ESP - ¡Leer! Informaciones importantes para la seguridad y el correcto funcionamiento.
Installation, use and maintenance guide
BOSKY SQUARE 30 – BOSKY SQUARE F30
ENG
Page 0

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the BOSKY SQUARE 30 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for THERMOROSSI BOSKY SQUARE 30

  • Page 1 Installation, use and maintenance guide BOSKY SQUARE 30 – BOSKY SQUARE F30 BOSKY SQUARE 30 – F30 BOSKY SQUARE 30 – F30 (READY TO START) ITA - MANUALE DI INSTALLAZIONE, USO E MANUTENZIONE. FRA - MANUEL D’INSTALLATION, D’UTILISATION ET D’ENTRETIEN.
  • Page 2 Installation, use and maintenance guide BOSKY SQUARE 30 – BOSKY SQUARE F30 Page 1...
  • Page 3: Table Of Contents

    Installation, use and maintenance guide BOSKY SQUARE 30 – BOSKY SQUARE F30 INDEX 1 – INTRODUCTION..........................5 2 – TECHNICAL CHARACTERISTICS...................... 7 3 – GENERAL DESCRIPTION ........................9 4 – INSTALLATION ..........................11 5 – PLUMBING SYSTEM CONNECTIONS AND DIAGRAMS ..............13 6 –...
  • Page 4 DECLARATION OF PERFORMANCE ACCORDING TO REGULATION (EU) 305/2011 Codice di identificazione unico del prodotto-tipo: BOSKY SQUARE 30 Modello, lotto, serie ai sensi dell'articolo 11, paragrafo 4: BOSKY SQUARE 30 Unique identification code of the product type: Model, batch or serial number required under Article 11(4):...
  • Page 5 Installation, use and maintenance guide BOSKY SQUARE 30 – BOSKY SQUARE F30 IT – SCHEDA PRODOTTO (UE 2015/1186) IT – MARCHIO EN – PRODUCT FICHE (EU 2015/1186) EN – BRAND FR – FICHE PRODUIT (UE 2015/1186) FR – MARQUE THERMOROSSI S.P.A.
  • Page 6: Introduction

    Furthermore, Thermorossi reserves the right to apply changes to the content of this manual anytime and without notice. Thermorossi S.p.A. retains copyright on this manual. These instructions may not be reproduced or communicated to third parties or used in any other way without the necessary authorisation.
  • Page 7 Installation, use and maintenance guide BOSKY SQUARE 30 – BOSKY SQUARE F30 ATTENTION: it is strictly forbidden to open the door while the flame is still burning. During operation, the smoke exhaust pipes, door, handles and some parts of the appliance may reach extremely high temperatures: be careful not to touch them and also educate children to be aware of said risks.
  • Page 8: Technical Characteristics

    Installation, use and maintenance guide BOSKY SQUARE 30 – BOSKY SQUARE F30 2 – TECHNICAL CHARACTERISTICS BOSKY SQUARE 30 BOSKY SQUARE F30 Height (mm) Depth (mm) Width (mm) 1,060 Weight (kg) Ø Internal smoke outlet (mm) Ø External smoke outlet (mm)
  • Page 9 Locazione file LIBRETTO ISTRUZIONI \\tr-dc01\DatiOffice\Reparti\Tecnico\DWG\Solid_edge\BOSKY_2017\BOSKY_2018_restyle_no_forno.asm Il presente disegno è di proprietà esclusiva di THERMOROSSI S.p.A.. La riproduzione totale e/o parziale e la divulgazione a terzi, senza nostro esplicito consenso scritto, verrà perseguito secondo i termini di legge in vigore Prodotto Descrizione...
  • Page 10: General Description

    Rear smoke exhaust Main ash pan Inspection cover Secondary ash pan Il presente disegno è di proprietà esclusiva di THERMOROSSI S.p.A.. La riproduzione totale e/o parziale e la divulgazione a terzi, senza nostro esplicito Prodotto Descrizione Pump active indicator light...
  • Page 11 Moving the Starter upwards activates the direct bypass for the flue gases, whereas on the contrary, pushing it downwards activates the normal flue gas path. Il presente disegno è di proprietà esclusiva di THERMOROSSI S.p.A.. La riproduzione totale e/o parziale e la divulgazione a terzi, senza nostro F – Primary air control...
  • Page 12: Installation

    Installation, use and maintenance guide BOSKY SQUARE 30 – BOSKY SQUARE F30 4 – INSTALLATION 4.1 APPLIANCE LOCATION Follow the general guidelines set out in paragraph 1.1 to the letter. Be aware that the flooring of the installation site must be capable of withstanding the weight of the appliance and the water contained in it. If this requirement is not met, it is obligatory to adopt countermeasures (for example, load distribution plate …).
  • Page 13 Fix the spacers (C2) to the screws (C1) that you have just Il presente disegno è di proprietà esclusiva di THERMOROSSI S.p.A.. La riproduzione totale e/o parziale e la divulgazione a terzi, senza nostro esplicito consenso scritto, verrà perseguito secondo i termini di legge in vigore.
  • Page 14: Plumbing System Connections And Diagrams

    Peso Volume System return fitting 1¼” F Il presente disegno è di proprietà esclusiva di THERMOROSSI S.p.A.. La riproduzione totale e/o parziale e la divulgazione a terzi, senza nostro esplicito consenso scritto, verrà perseguito secondo i termini d LAMIERA Disegnatore...
  • Page 15 Thermal relief valve outlet – safety heat exchanger outlet Il presente disegno è di proprietà esclusiva di THERMOROSSI S.p.A.. La riproduzione totale e/o parziale e la divulgazione a terzi, senza nostro esplicito consenso scritto, verrà perseguito s Il presente disegno è di proprietà esclusiva di THERMOROSSI S.p.A.. La riproduzione totale e/o parziale e la divulgazione a terzi, senza nostro esplicito consenso scritto,...
  • Page 16 The nominal volume of the closed expansion tank must be sized in relation to the total volume of the water contained in the system. Thermorossi prescribes the size of the closed expansion tank as equal to 10% of the volume of water contained in the entire system.
  • Page 17 Installation, use and maintenance guide BOSKY SQUARE 30 – BOSKY SQUARE F30 BOSKY SQUARE + VASO APERTO 5.4 SCHEMATIC DIAGRAM OF TYPICAL OPEN EXPANSION TANK HYDRAULIC SYSTEM TDSC Safety heat exchanger Heating plant delivery (standard only in the READY TO START version)
  • Page 18 BOSKY SQUARE + VASO CHIUSO Installation, use and maintenance guide BOSKY SQUARE 30 – BOSKY SQUARE F30 5.5 SCHEMATIC DIAGRAM OF TYPICAL CLOSED EXPANSION TANK HYDRAULIC SYSTEM VM3VT Additional closed expansion tank, sized to at least 10% of Heating plant delivery...
  • Page 19 Installation, use and maintenance guide BOSKY SQUARE 30 – BOSKY SQUARE F30 5.6 SCHEMATIC DIAGRAM OF TYPICAL CLOSED EXPANSION TANK HYDRAULIC SYSTEM WITH PUFFER BOSKY SQUARE + VASO CHIUSO -+ PUFFER TANK VM3VT COLD Safety heat exchanger Supply to the puffer tank...
  • Page 20: Assembling The Components

    Data Autore Data Il presente disegno è di proprietà esclusiva di THERMOROSSI S.p.A.. La riproduzione totale e/o parziale e la divulgazione a terzi, senza nostro esplicito consenso scritto, verrà perseguito secondo i termini di legge in vigore. Prodotto Descrizione BOSKY SQUARE 30...
  • Page 21 Il presente disegno è di proprietà esclusiva di THERMOROSSI S.p.A.. Prodotto Desc Il presente disegno è di proprietà esclusiva di THERMOROSSI S.p.A.. La riproduzione totale e/o parziale e la divulgazione a terzi, senza nostro esplicito consenso scritto, verrà perseguito secondo i termini di legge in vigore. Note Prodotto...
  • Page 22: Use Of The Appliance

    Installation, use and maintenance guide BOSKY SQUARE 30 – BOSKY SQUARE F30 7 – USE OF THE APPLIANCE The appliance, when operating, is hot to the touch, particularly the door of the combustion chamber and the cooktop: consequently, take care not to touch any surface. Your appliance has obtained the CE marking. The product must not...
  • Page 23 Installation, use and maintenance guide BOSKY SQUARE 30 – BOSKY SQUARE F30 7.2 REFUELLING The stove is an intermittent combustion appliance so it requires refuelling. Once combustion is achieved inside the combustion chamber and consequently there are embers present, proceed with the first fuel feed: 1) Raise the starter using the special riddling tool.
  • Page 24 By acting on the smoke deviator flap (see figure on the side) the product can be used in several modes: Il presente disegno è di proprietà esclusiva di THERMOROSSI S.p.A.. La riproduzione totale e/o parziale e la divulgazione a terzi, senza nostro esplicito cons - Only heating (flap up)
  • Page 25 Installation, use and maintenance guide BOSKY SQUARE 30 – BOSKY SQUARE F30 7.8 PRESCRIPTIONS FOR CORRECT OPERATION - Respect the maximum declared consumption, do not overload the stove with excessive quantities of fuel as this could cause damage. LOADING A LARGER QUANTITY OF FUEL OR LOADING SEVERAL TIMES IN AN HOUR EXPOSES THE COMPONENTS OF THE APPLIANCE TO VERY HIGH TEMPERATURES.
  • Page 26: Cleaning And Maintenance

    Installation, use and maintenance guide BOSKY SQUARE 30 – BOSKY SQUARE F30 8 - CLEANING AND MAINTENANCE 8.1 FOREWORD To guarantee correct operation and optimal performance of the appliance at all times carry out the operations described below. Observe the recommended frequency.
  • Page 27 Installation, use and maintenance guide BOSKY SQUARE 30 – BOSKY SQUARE F30 EVERY WEEK: Open the door, unscrew the two knobs indicated in the photo below, remove the secondary ash pan and empty it. We recommend emptying the ash pan regularly before it fills up completely.
  • Page 28: Smoke Discharge Tube

    Installation, use and maintenance guide BOSKY SQUARE 30 – BOSKY SQUARE F30 9 - SMOKE DISCHARGE TUBE 9.1 FOREWORD Due to the frequent accidents caused by poor functioning of flue outlets installed in private dwellings, we have prepared the following paragraph to assist the installer in his inspection of the parts concerned with eliminating the gases produced by combustion.
  • Page 29 (DA) and fix it with the supplied bolts (DB), nuts (DC) and washers (DG). Il presente disegno è di proprietà esclusiva di THERMOROSSI S.p.A.. La riproduzione totale e/o parziale e la divulgazione a terzi, senza nostro esplicito consenso scritto, verrà perseguito secondo i termini di legge in vigore.
  • Page 30 Installation, use and maintenance guide BOSKY SQUARE 30 – BOSKY SQUARE F30 9.3.4 CONTROLS PRIOR TO INSTALLING THE APPLIANCE The user must possess a certificate of conformance for the flue outlet (Ministerial Decree 22 January 2008, no. 37). The flue outlet must be built in compliance with UNI 10683.
  • Page 31: Problems, Causes And Solutions

    Installation, use and maintenance guide BOSKY SQUARE 30 – BOSKY SQUARE F30 10 - PROBLEMS, CAUSES AND SOLUTIONS PROBLEM CAUSE SOLUTION Blocked grate. Clean the grate. Moist wood or too thick. Use smaller sized and more seasoned wood. Clean the ash pan.
  • Page 32: Spare Parts

    Installation, use and maintenance guide BOSKY SQUARE 30 – BOSKY SQUARE F30 11 - SPARE PARTS Page 31...
  • Page 33 Installation, use and maintenance guide BOSKY SQUARE 30 – BOSKY SQUARE F30 70026926 Telaio porta superiore assemblato 60013056 Vite fermo maniglia 60010335 Treccia fibra vetro D.8 Page 32...
  • Page 34 Installation, use and maintenance guide BOSKY SQUARE 30 – BOSKY SQUARE F30 70031042 Telaio posteriore inox per piano cottura Bosky Square F 70028978 Telaio posteriore inox per piano cottura Bosky Square Page 33...
  • Page 35 Installation, use and maintenance guide BOSKY SQUARE 30 – BOSKY SQUARE F30 Page 34...
  • Page 36 Installation, use and maintenance guide BOSKY SQUARE 30 – BOSKY SQUARE F30 Page 35...
  • Page 37 Installation, use and maintenance guide BOSKY SQUARE 30 – BOSKY SQUARE F30 KEY 2 KEY 1 70011922 60012922 Complete ash pan Thermal safety relief valve CALEFFI 3/4 F-F SERIES 543513 70026454 70026683 Ash pan holder Fitting 3/4" ITAP 70026418 60012595...
  • Page 38 Installation, use and maintenance guide BOSKY SQUARE 30 – BOSKY SQUARE F30 KEY 3 70026697 KEY 4 Secondary air box 70026882 LH side casing white 70022818 70026883 LH side casing gunmetal SCREW AISI 304 TCEI M5X40 A2 70026886 LH side casing bordeaux...
  • Page 39 Installation, use and maintenance guide BOSKY SQUARE 30 – BOSKY SQUARE F30 KEY 5 70011835 Enamelled dripping pan 70026740 Oven grate 70026739 Oven side grate Bosky F 70026739 Oven side grate Bosky F 70027926 Oven front casing panel Bosky black enamel...
  • Page 40 Installation, use and maintenance guide BOSKY SQUARE 30 – BOSKY SQUARE F30 F ire L o v e rs Via Grumolo, 4 (Z.I.) 36011 Arsiero (VI) - ITALY Fax 0445.741657 - www.thermorossi.com - info@thermorossi.it Page 39...