THERMOROSSI Freeline Series Installation, Use And Maintenance Manual

Advertisement

Installation, use and maintenance guide
FREE LINE WOOD STOVES
FREELINE SERIES
ITA - MANUALE DI INSTALLAZIONE, USO E MANUTENZIONE.
FRA - MANUEL D'INSTALLATION, D'UTILISATION ET ENTRETIEN.
ENG - INSTALLATION, USE AND MAINTENANCE GUIDE.
DEU - INSTALLATIONS, BETRIEBS UND WARTUNGSANLEITUNG.
ESP - MANUAL DE INSTALACIÓN USO Y MANTENIMIENTO.
NL - HANDLEIDING VOOR INSTALLATIE, GEBRUIK EN ONDERHOUD.
ITA - Informazioni importanti per la sicurezza ed il corretto funzionamento.
FRA - A lire impérativement ! Informations importantes pour la sécurité et le bon fonctionnement.
ENG - Must read! Important information for safety and correct operation.
DEU - Unbedingt lesen! Wichtige informationen zur sicherheit und zum sicheren betrieb.
ESP - ¡Leer! Informaciones importantes para la seguridad y el correcto funcionamiento.
NL - Belangrijke informatie voor de veiligheid en de correcte werking.
Page 0

Advertisement

Table of Contents
loading

Summary of Contents for THERMOROSSI Freeline Series

  • Page 1 Installation, use and maintenance guide FREE LINE WOOD STOVES FREELINE SERIES ITA - MANUALE DI INSTALLAZIONE, USO E MANUTENZIONE. FRA - MANUEL D’INSTALLATION, D’UTILISATION ET ENTRETIEN. ENG - INSTALLATION, USE AND MAINTENANCE GUIDE. DEU - INSTALLATIONS, BETRIEBS UND WARTUNGSANLEITUNG. ESP - MANUAL DE INSTALACIÓN USO Y MANTENIMIENTO.
  • Page 2 Installation, use and maintenance guide FREE LINE WOOD STOVES Page 1...
  • Page 3: Table Of Contents

    7 – CLEANING AND MAINTENANCE .....................19 8 – SMOKE EXHAUST TUBE ........................22 9 – PROBLEMS, CAUSES AND SOLUTIONS ..................24 EU Declaration of Conformity (DoC) EU Declaration of Conformity (DoC) Company name: THERMOROSSI S.P.A. Company: Postal address: VIA GRUMOLO, N° 4 Address: Postcode and city: 36011 ARSIERO (VI) Codice postale e città:...
  • Page 4 Name and address of the agent as required pursuant Article 12 (2): THERMOROSSI S.P.A. Via Grumolo, n° 4 36011 Arsiero (VI) Sistema di valutazione e verifica della costanza della prestazione del prodotto da costruzione di cui all'allegato V: Sistema 3...
  • Page 5 Name and address of the agent as required pursuant Article 12 (2): THERMOROSSI S.P.A. Via Grumolo, n° 4 36011 Arsiero (VI) Sistema di valutazione e verifica della costanza della prestazione del prodotto da costruzione di cui all'allegato V: Sistema 3...
  • Page 6 Name and address of the agent as required pursuant Article 12 (2): THERMOROSSI S.P.A. Via Grumolo, n° 4 36011 Arsiero (VI) Sistema di valutazione e verifica della costanza della prestazione del prodotto da costruzione di cui all'allegato V: Sistema 3...
  • Page 7: Introduction

    If the appliance is sold or transferred to another user ensure that the manual is handed over with it. The images and figures featured in this manual are purely illustrative and may differ from the actual product. Furthermore, Thermorossi reserves the right to apply changes to the content of this manual anytime and without notice.
  • Page 8 Installation, use and maintenance guide FREE LINE WOOD STOVES 1.2 SAFETY STANDARDS PERSONAL INJURY T his safety symbol identifies important messag es thr oughout the manual. Read the information marked by this symbol carefully as non -observance of this message can cause seriou s injury to persons using the appliance.
  • Page 9: Technical Characteristics

    Installation, use and maintenance guide FREE LINE WOOD STOVES 2 – TECHNICAL CHARACTERISTICS VITTORIA SOFIA EVO ILARIA EVO FILÒ ANNA EVO AGORÀ Height (mm) 1.011 1.133 1.550 Depth (mm) Width (mm) Weight with casing Easy (kg) Weight with casing Ceramica (kg) Smoke outlet diameter (mm) Minimum draught (Pa) Maximum permitted fuel feed Kg ***...
  • Page 10 FREE LINE WOOD STOVES FILÒ Il presente disegno è di proprietà esclusiva di THERMOROSSI S.p.A.. La riproduzione totale e/o parziale e la divulgazione a terzi, senza nostro esplicito consenso scritto, verrà perseguito secondo i termini di legge in vigore. Prodotto...
  • Page 11: General Description

    Ash pan Primary air control Il presente disegno è di proprietà esclusiva di THERMOROSSI S.p.A.. La riproduzione totale e/o parziale e la divulgazione a terzi, senza nostro esplicito consenso scritto, verrà perseguito secondo i termini di legge in vigore. Prodotto...
  • Page 12 Installation, use and maintenance guide FREE LINE WOOD STOVES B – Smoke by-pass This device creates a direct bypass for the flue gases which facilitates both the lighting and refuelling operations. The riddling tool provided must be used when activating it and only when lighting or stoking the fire. IT IS PROHIBITED TO LEAVE THE SMOKE BY-PASS OPEN DURING NORMAL OPERATION.
  • Page 13 The glove provided must be worn when handling them. SBLOCCAGGIO E SUCCESSIVA CHIUSURA REGOLAZIONE ARIA SECONDARIA Il presente disegno è di proprietà esclusiva di THERMOROSSI S.p.A.. La riproduzione totale e/o parziale e la divulgazione a terzi, senza nostro esplicito consenso scritto, v Prodotto Descrizione...
  • Page 14: Installation

    NOT BE COVERED BY THE WARRANTY. Il presente disegno è di proprietà esclusiva di THERMOROSSI S.p.A.. La riproduzione totale e/o parziale e la divulgazione a terzi, senza nostro esplicito consenso scritto, verrà perseguito secondo i termini di legge in vigore.
  • Page 15: Assembling The Casing

    Installation, use and maintenance guide FREE LINE WOOD STOVES 5 – ASSEMBLING THE CASING The appliance is supplied with pre-mounted casings. For the majolica models: ATTENTION: The majolica tiles are handcrafted so they could contain subtle surface imperfections, crazing or shade variations.
  • Page 16 Installation, use and maintenance guide FREE LINE WOOD STOVES ATTENTION: THE DOOR OF THE COMBUSTION CHAMBER AND OF THE ASH PAN MUST ONLY BE OPENED FOR THE LIGHTING OPERATIONS, FOR STOKING AND FOR REMOVING RESIDUAL MATERIAL. DURING NORMAL OPERATION THE FIREBOX DOOR MUST REMAIN SECURELY CLOSED AND THE SMOKE BY-PASS DEACTIVATED.
  • Page 17 POSIZIONE BLOCCAGGIO 1 E 2 POSIZIONE BLOCCAGGIO 2 SBLOCCAGGIO SBLOCCAGGIO Il presente disegno è di proprietà esclusiva di THERMOROSSI S.p.A.. La riproduzione totale e/o Prodotto Il presente disegno è di proprietà esclusiva di THERMOROSSI S.p.A.. La riproduzione to Descrizione Il presente disegno è di proprietà esclusiva di THERMOROSSI S.p.A.. La riproduzione totale e Il presente disegno è...
  • Page 18 Figure 3 Figure 4 Il presente disegno è di proprietà esclusiva di THERMOROSSI S.p.A.. La riproduzione totale e/o parziale e la divulgazione a terzi, senza nostro esplicito consenso scritto, verrà perseguito secondo i termini di legge in vigore. Prodotto Descrizione...
  • Page 19 WILL NOT COVER ANY DAMAGE CAUSED BY PROLONGED EXPOSURE OF THE APPLIANCE TO THESE TEMPERATURES. Il presente disegno è di proprietà esclusiva di THERMOROSSI S.p.A.. La riproduzione totale e/o parziale e la divulgazione a terzi, senza nostro esplicito consenso scritto, verrà perseguito secondo i termini di legge in vigore. Prodotto...
  • Page 20: Cleaning And Maintenance

    Installation, use and maintenance guide FREE LINE WOOD STOVES 7 – CLEANING AND MAINTENANCE 7.1 FOREWORD To guarantee correct operation and optimal performance of the appliance at all times carry out the operations described below. Observe the recommended frequency. If the product is unused for a prolonged period of time before starting up it is mandatory to inspect the smoke channel and outlet to ensure that there are no obstructions.
  • Page 21 Installation, use and maintenance guide FREE LINE WOOD STOVES EVERY TWO DAYS or WHENEVER NECESSARY: • Empty the ash pan. We recommend emptying the ash pan regularly before it fills up completely. EVERY WEEK: Use an ash vacuum device to clean the combustion chamber. EVERY 6 MONTHS: Activate the Smoke by-pass and clean the flue gas path with a flue brush as illustrated in the following photo: Page 20...
  • Page 22 Installation, use and maintenance guide FREE LINE WOOD STOVES Lift the warming plate with the supplied riddling tool. Thoroughly clean the smoke circuit with an ash vacuum cleaner. AT LEAST ONCE A YEAR: Clean the flue outlet. If there are any horizontal sections, inspect them and clean out any ash and soot deposits before they block the passage of the flue gases.
  • Page 23: Smoke Exhaust Tube

    Installation, use and maintenance guide FREE LINE WOOD STOVES 8 – SMOKE EXHAUST TUBE 8.1 FOREWORD Due to the frequent accidents caused by poor functioning of flue outlets installed in private dwellings, we have prepared the following paragraph to assist the installer in his inspection of the parts concerned with eliminating the gases produced by combustion.
  • Page 24 Installation, use and maintenance guide FREE LINE WOOD STOVES 8.3.2 FLUE OUTLET / FLUE SYSTEM COMPONENTS Every chimney must have minimum number of components as laid down Components and accessories of a by standard UNI EN 1443 which are also indicated in the figure on the chimney side.
  • Page 25: Problems, Causes And Solutions

    Installation, use and maintenance guide FREE LINE WOOD STOVES 9 – PROBLEMS, CAUSES AND SOLUTIONS PROBLEM CAUSE SOLUTION Blocked grate. Clean the grate. Moist wood or too thick. Use smaller sized and more seasoned wood. Clean the ash pan. Remove the warming plate and thoroughly clean Difficulty in lighting the the flue gas path and the flue outlet cooker.
  • Page 26 Installation, use and maintenance guide FREE LINE WOOD STOVES Page 25...
  • Page 27 Installation, use and maintenance guide FREE LINE WOOD STOVES Page 26...
  • Page 28 Installation, use and maintenance guide FREE LINE WOOD STOVES F ire L o v e rs Via Grumolo, 4 (Z.I.) 36011 Arsiero (VI) - ITALY Fax 0445.741657 - www.thermorossi.com - info@thermorossi.it Page 27...

This manual is also suitable for:

Sofia evoIlaria evoFiloVittoria evoAnna evoAgora

Table of Contents