Summary of Contents for Nilfisk-Advance ATTIX 30-0H
Page 1
ATTIX 30 H/M / PC / XC ATTIX 50 H/M / PC / XC Instructions for use WARNUNG: Dieses Gerät enthält gesundheitsgefährliche Stäube. Entleerung und Wartung einschließlich Entfernung des Staubbeutels dürfen nur von sachkundigen Personen vorgenommen werden, die geeignete persönliche Schutz- ausrüstung tragen.
1 IMPORTANT SAFETY INSTRUCTIONS Symbols used to mark instructions DANGER Danger that leads directly to serious or irreversible injuries, or even death. WARNING Danger that can lead to serious injuries or even death. CAUTION Danger that can lead to minor injuries and damage. Before starting up your machine for the first time, this instruction manual must be read through carefully.
Page 17
hazardous dusts with OEL values > 0.1 mg/m³ Dust Class M (IEC 60335-2-69). The dusts which belong to this class are: dusts with OEL values > 0.1 mg/m³ as well as saw dust. The machine is tested in its entirety by vacuums for this dust class.
Page 18
gasoline, or use in areas where they may be pre sent. • Do not pick up anything that is burning or smoking, such as ciga- rettes, mat ches or hot ashes. • Use extra care when cleaning on stairs. • Do not use unless filters are fitted. •...
Page 19
The machine is equipped with a specially designed cord which if damaged, must be replaced by a cord of the same type. This is available at authorised service centres and dealers and must be in- stalled by trained personnel. Only applicable to UK. Please read these essential instructions These instructions have been prepared with safety and efficiency paramount.
Page 20
• Do not unplug by pulling on cable. To unplug, grasp the plug, not the cable. The plug must always be removed from the socket outlet before starting any service or repair work of the machine or the ca- ble. •...
Page 21
No. 2.7 (e.g. not only the outer case but also, for example, the cooling air rooms, the installation rooms for electrical supplies, the supplies themselves, etc.). A written report must be made by a specialist and signed by him. When picking up materials containing asbestos the exhaust air must not be returned into the room.
Page 22
Description Handle with receptacle for Inlet fitting Operating elements electrical lead Appliance switch Fixing point for suction Hose diameter setting pipe holder Appliance socket * Retaining clamp Operating knob for filter Castor cleaning * Dirt tank Symbols Pages 4 – 15 feature a pictorial This quick reference guide does rating instructions also contain quick reference guide, which is...
Operation Appliance socket * The appliance socket is only de- the vacuum cleaner and the signed for the purposes defined appliance that is to be con- in the operating instructions. The nected. connection of different appliances 2. Read the operating instructions can result in damage.
Applications and techniques Techniques If used correctly, additional ac- Effective cleaning is achieved if cessories, suction nozzles and you follow just a few guidelines in suction hoses can enhance the combination with your own practi- cleaning action and reduce the cal experience in special fields.
Troubleshooting Fault Cause Remedy ‡ Motor does not start > Fuse of the mains socket has blown. • Connect mains fuse. > Overload protection switch has • Switch off the vacuum cleaner and tripped. allow it to cool for approx. 5 minutes. If the cleaner cannot be started again, contact the Nilfisk service department.
Page 28
Nilfisk déclare sous notre seule responsabilité Noi, Nilfisk Prin prezenta declarăm pe propria que le produit mentionné ci-dessus est răspundere, că produsul mai sus menționat conforme aux directives et normes suivantes. este în conformitate cu următoarele standarde și directive Me, Nilfisk täten vakuutamme omalla Мы, Nilfisk настоящим...
Page 29
UK Declaration of Conformity Nilfisk Ltd Nilfisk House, Bowerbank Way Gilwilly Industrial Estate Penrith Cumbria CA11 9BQ UK Hereby declare under our sole responsibility that the Products: VAC - Commercial - Wet/Dry Description: 220-240V 50-60Hz, IPX4 Type: ATTIX 30/40/50 PC/XC/EC Are in compliance with the following standards: EN 60335-1:2012+A11:2014+A13:2017 EN 60335-2-69:2012...
Page 30
HEAD QUARTER GREECE SLOVAKIA Nilfi sk A.E. Nilfi sk s.r.o. DENMARK Tel.: +30 210 911 9600 Tel.: +421 948 339 353 Nilfi sk A/S www.nilfi sk.com www.nilfi sk.com Tel.: +45 43 23 81 00 www.nilfi sk.com NETHERLANDS SOUTH AFRICA Nilfi sk B.V. Nilfi...
Need help?
Do you have a question about the ATTIX 30-0H and is the answer not in the manual?
Questions and answers