10/1/2020 TAG08/08B Configuration Manual V1.0.2 Content 1. USB RS232 Cable...........................2 Step..............................2 3. Configure Software......................... 9 ID............................9 Low Voltage Alarm (01)......................9 Heartbeat (02)..........................9 Temperature humidity alarm (03)....................9 Transmit Power (04)........................10 Set RTC time (06)........................10 Set the maximum sending delay time (07)................
10/1/2020 1. USB RS232 Cable The RS232 cable is modified based on the normal RS232 Cable. It can be used to configure TAG on personal computer. Before using configuration software, please connect our TAG to computer via our RS232 cable. The smaller USB port connects with the TAG USB port , the bigger USB port connects with the computer.
Page 3
10/1/2020 4) If the TAG is not turn on, please press the button for 3 second ,when the TAG is turned on,open the cover of TAG, connect TAG USB with computer via the configuration cable, the TAG status led will be on, means the tag is in configuration mode (If tag is not operated , the configuration mode will exit after 1 minute, and the status light will go out.
Page 4
10/1/2020 6) Please select the TAG type and correct COM port. Then click[ ] button on the software. If the port connects successfully, it will show that the serial port is opened[ ] and click [Read] all the parameter will be shown on the software, the mean is that reading the machine successfully.
Page 5
[1-1440], unit:min, default:30 Set heartbeat *02,X# X: [1-1440], unit:min, default:15 packet interval Set high/low *03,A,X,Y, A=0: disable this function (default) temperature A=1: enable this function alarming X: high temperature threshold, [-40-125], function(TAG08) unit: ℃, default:100; Y: low temperature threshold, [-40-125],...
Page 6
10/1/2020 unit:℃, default:0; Z:transmit interval after temperature alarming, [1-1440], unit:min, default:1 Set high/low *03,A,X,Y, A=0: disable this function (default) temperature/ M,N,Z# A=1: enable this function humidity alarming X: high temperature threshold, [-40-125], function(TAG08B) unit:℃, default:100; Y: low temperature threshold, [-40-125], unit:℃, default:0;...
Page 7
12 Turn off the buzzer *37,0# sending *40,X# X=0,Not included RTC time, humidity unit is %; protocol X=1,Including RTC time,humidity unit is % (tag08 default); X=2,,Not included RTC time, humidity unit is 0.1%; X=3,Including RTC time,humidity unit is 0.1% (tag08B default); removal *41,X# X:Temperature value,[0,120],default:0, unit:℃...
Page 8
10/1/2020 humidity, it begins with +; If the calibration value is reduction to the humidity, it begins with -; Can support to one decimal point, unit: % 15 Save command 16 Search single #D5X X: command command 17 Search all commands 18 Query current temperature and...
Interval: The TAG data time interval,[1-1440], unit:min, default:15 Temperature humidity alarm (03) temperature&humidity alarm function, suggest you also enable the if you want enable buzzer alarm function, it is 36 command . TAG08: Enable: enable TAG alarm function If sensor’s temperature exceed Temp_H、under Temp_L alert.
10/1/2020 Extend Setting (09) Enable ACK: When enable ACK function,if the sensor does not receive an ACK reply from the LORA Gateway, the data will be stored. when the sensor receives an ACK reply from the LORA Gateway, the stored data will be sent out Enable RTC: when enable RTC time function, the sensor data received by the LORA Gateway is the current time of the sensor,otherwise, it is the time of the LORA Gateway...