RAPID CONFIGURATION

1 RAPID CONFIGURATION
STEP 1 – CONNECTING THE SYSTEM
To connect the system in a Stand Alone configuration, you need the hardware indicated in
Figure 1. In this layout the data is transmitted to the Host on the RS232 auxiliary serial
interface which is also used for reader configuration by running VisiSet™.
When One Shot or Phase Mode Operating mode is used, the reader is activated by an
External Trigger (photoelectric sensor) when the object enters its reading zone.
Matrix-1000™
* External Trigger or Presence Sensor (for One Shot or Phase mode)
C-BOX 100 Pinout for Matrix-1000™
The table below gives the pinout of the C-BOX 100 terminal block connectors. Use this
pinout when the Matrix-1000™ reader is connected by means of the C-BOX 100:
1, 3, 5
VS
2, 4, 6
GND
7, 8
EARTH GROUND
20, 40
Reserved
27
EXT TRIG A (polarity insensitive)
28
EXT TRIG B (polarity insensitive)
29, 30
NC
31, 33
NC
32, 34
NC
36
NC
Do not connect GND and SGND to different (external) ground references.
GND and SGND are internally connected through filtering circuitry which
can be permanently damaged if subjected to voltage drops over 0.8 Vdc.
CAUTION
CAB-600X
CBOX-100
P.S.*
PG 6000
Figure 1 – Matrix-1000™ in Stand Alone Layout
C-BOX 100 Terminal Block Connectors
Power
Inputs
Aux Interface
21, 22
NC
23, 24
NC
25
OUT 3+
26
OUT 3-
Auxiliary Interface RS232
35
TX AUX
37
RX AUX
38,39
GND
Main Interface RS485 Half Duplex
11, 15
RTX 485+
12, 16
RTX 485-
17
NC
18
NC
10, 14, 19
SGND
9, 13
RS485 Cable Shield
Local Host
Outputs
1
1