Datalogic Reader Matrix-1000 Reference Manual page 37

Datalogic scanning ccd reader reference manual
Hide thumbs Also See for Reader Matrix-1000:
Table of Contents

Advertisement

INSTALLATION
The electrical features of the output are the following:
× I
P
= V
D
Out
MATRIX
+
V
Out
-
Figure 30 - Open Collector Output Connection
OUTPUT
I
Load
Open
0 mA
Closed
10 mA
= 170 mW Max.
oLoad
USER INTERFACE
Vext 30 Vdc max
I
Load
V
Out
30 Vdc Max
1.8 Vdc Max
3
29

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents