SECTION 2: CIRCUIT REQUIREMENTS

110/220V Operation

Serious personal injury could occur if you
connect the machine to the power source
before you have completed the set up pro-
cess. DO NOT connect the machine to the
power source until instructed to do so.
Amperage Draw
The Model G0448 features a 1
motor that is prewired at 110V.
Motor Draw at 110V ............................... 14 Amps
Motor Draw at 220V ................................ 7 Amps
Circuit Requirements
Only connect your machine to a circuit that meets
the requirements below. Always check to see if
the wires and circuit breaker in your circuit are
capable of handling the amperage draw from
your machine, as well as any other machines that
could be operating on the same circuit. If you are
unsure, consult a qualified electrician.
110V Circuit ............................................. 15 Amp
220V Circuit ............................................. 15 Amp
G0448 Mortising Machine
HP 110/220V
1
2
Plug Type
The Model G0448 comes prewired with a NEMA
5-15 plug. If you wish to rewire the motor to 220V
we recommend using the following plug (see
Figure 5 for an example):
220V Plug & Receptacle .............................. 6-15
Figure 5. 220V 6-15 plug and outlet.