Supplemental Flight Data; Generic Timer - Garmin G900X Pilot's Manual

Integrated flight deck
Hide thumbs Also See for G900X:
Table of Contents

Advertisement

FLIGHT INSTRUMENTS

2.2 SUPPLEMENTAL FLIGHT DATA

Selecting the DFLTS Softkey (a second-level PFD softkey) turns off metric Altimeter display, the Inset
NOTE:
Map, and wind data display.
In addition to the flight insturments, the PFD also displays various supplemental information, including a
generic timer, the Outside Air Temperature (OAT), wind data, the system time, and Vertical Navigation (VNV)
indications.

GENERIC TIMER

The Timer/References Window contains a generic timer, which can be set to count up or down from a
specified time (HH:MM:SS). When the countdown on the timer reaches zero, the digits begin to count up from
zero. If the timer is reset before reaching zero on a countdown, the digits are reset to the initial value. If the
timer is counting up when reset, the digits are zeroed.
Setting the generic timer:
1) Select the TMR/REF Softkey.
2) Turn the large FMS Knob to select the timer field (hh/mm/ss).
3) Use the FMS Knob to enter the desired time and press the ENT Key.
4) With the UP/DN field highlighted, turn the small FMS Knob to select the timer counting direction.
5) Press the ENT Key.
6) With 'START?' highlighted, press the ENT Key to start the timer. The field changes to 'STOP?'.
7) To stop the timer, press the ENT Key with 'STOP?' highlighted. The field changes to 'RESET?'.
8) To reset the timer, press the ENT Key with 'RESET?' highlighted. The field changes back to 'START?' and the
digits are reset.
9) To remove the window, press the CLR Key or the TMR/REF Softkey.
2-22
Figure 2-30 Timer/References Window
Garmin G900X Pilot's Guide
190-00726-00 Rev. A