WARNING!
Read and understand the contents of this manual before attempting to
service the ECOSTREAM Water Treatment System. Failure to follow the instructions in
this manual could result in death, serious personal injury, or severe property damage.
Only trained and qualified technicians should attempt to install, maintain, or service
Waterlogic Equipment.
1. Visually inspect all electrical and water connections for signs of wear or damage.
DANGER!
HIGH VOLTAGE ELECTRICAL HAZARD. Unplug before inspection and service.
2. Waterlogic recommends changing the UV Lamp every 12 months.
NOTE:
When replacing the UV Lamp Assembly, the UV Lamp
wiring harness must also be replaced.
NOTE:
The Glow Starter shown to the right may appear
blackened which is normal.
UV Lamp Assembly with Glow Starter Part #'s:
4-Watt Bulb 12-2350 (CT-2084) used in
countertop model
8-Watt Bulb 10-2350 (CT-2083) used in Tower
Glow Starter
Ecostream Manual
SERVICE REQUIREMENTS
model
UV Lamp Connectors
Glow Starter
Page 12 - Revision: 11-13-2020

Advertisement

loading
Need help?

Need help?

Do you have a question about the Ecostream and is the answer not in the manual?

Questions and answers

Summary of Contents for WaterLogic Ecostream

  • Page 1 WARNING! Read and understand the contents of this manual before attempting to service the ECOSTREAM Water Treatment System. Failure to follow the instructions in this manual could result in death, serious personal injury, or severe property damage. Only trained and qualified technicians should attempt to install, maintain, or service Waterlogic Equipment.
  • Page 2 4. Inspect the Quartz Sleeve O-ring for wear or damage and replace as necessary. 5. Ensure there is adequate (minimum of 2”) clearance around the ECOSTREAM Water Treatment System and clean the condenser grill and compressor fan to provide efficient cooling system operation.
  • Page 3: External Capacitor

    External Capacitor LG CSB035LJCM 120V R134A 1/8HP Compressor Repair Parts Part # CO-0017-L00-00 LG Compressor 120V CSB035LJCM-PTC Relay Part # CO-0018-L00-00 LG Compressor 120V CSB035LJCM-Overload Protector Part # CO-0019-L00-00 LG Compressor 120V CSB035LJCM-Capacitor Ecostream Manual Page 14 - Revision: 11-13-2020...
  • Page 4: Hot Tank Principles Of Operation

    HOT TANK PRINCIPLES OF OPERATION Vent Outlet Hot Tank Outlet To Faucet All Waterlogic Hot Tanks have a built in Vent or Expansion Chamber in the top of the tank except for WL270 (GF) units. Expansion Outlet Vent Chamber The Vent Chamber allows for expansion of the water when it is Hole heated.
  • Page 5 Red Heater and Compressor Switch must be in the OFF position O=OFF Unplug the Power Cord from rear of ECOSTREAM Water Treatment System. Tower Model: Remove the Lower Front Panel by removing the Phillips Head Screws underneath the Lower Front Panel.
  • Page 6 Make sure the Hot and Cold Tanks are filled with water BEFORE turning on the Red Heater and Compressor Switch. Verify the cooler is fully operational before installing it at the customers’ site. Ecostream Manual Page 17 - Revision: 11-13-2020...
  • Page 7: Materials Needed

    2. Connect descaling cartridge to the inlet water supply and connect to inlet bulkhead fitting on the back of the ECOSTREAM Water Treatment System. Turn on Water Supply. 3. Select Hot Water and depress the Main Dispensing Button on the Front Control Panel until descaling solution (colored water) comes out of the faucet.
  • Page 8 5. Allow descaling solution to remain in the Hot Tank for 15 minutes (length of time may vary depending on water conditions). 6. Place a pitcher, catch basin or other container under the faucet of the ECOSTREAM Water Treatment System.
  • Page 9 FT-0053-IL-WLT CAUTION! Use only Waterlogic Replacement parts that can be obtained from Waterlogic or an Authorized Waterlogic Dealer, failure to do so will void the Warranty. See Installation and Service Manual for additional information. Hot Tank Service Hot Tanks (with controls) must be replaced at least every 3-5 years depending on usage.
  • Page 10 ECOSTREAM COUNTER TOP DRAWING AND PARTS LIST Wetted Drawing Yellow = Consumables Green = Recommended spare parts Ecostream Manual Page 21 - Revision: 11-13-2020...
  • Page 11: Recommended Spare Parts

    Faucet Nipple – Blue with Screen PL-1013 Recommend stocking 2 each per every 10 units purchased Natural Faucet O-Ring – Silicon White 10-2600 CT-2007 Recommend stocking 2 each per every 10 units purchased Ecostream Manual Page 22 - Revision: 11-13-2020...
  • Page 12 JG Equal Tee Connector ¼” from John PU-4011 (P10208S) Guest 10-3017 PCB Stand-off Pin EN-6059 UV Lamp Retaining Threaded 12-1210 PL-1128 12-3117 Power Transformer 120V EL-5003-A Upper Shelf 12-3165 ST-0276-L00-00 12-3110 2L UV Cold Tank Assembly CT-2060 Ecostream Manual Page 23 - Revision: 11-13-2020...
  • Page 13 JG Equal Elbow Connector ¼” PU-4008 from John (PI0308S) Guest 12-3175 WL2100 Mini Filter Bracket ST-8152-B WL2000 Mini Firewall Solenoid ST-0277 Valve Fixing Bracket 12-3150 Unit Rubber Feet PL-1251-CN WL2100 Mini Bottom Tray 12-3170 ST-8151-A (Down Panel) Ecostream Manual Page 24 - Revision: 11-13-2020...
  • Page 14 CT-2070-A 34.1 LP-0326 Cold Thermostat Cover Label LP-0326-L00-00 Socket for Plug Connection V0 EL-0061-L00-00 Class Fuse Holder and Fuse 120V / EL-5053 15A with One Wire 36.1 10-3013 Fuse 120V / 15A EL-5010 Ecostream Manual Page 25 - Revision: 11-13-2020...
  • Page 15 John Guest P/N PE-0806- PU-4014 100M-B Faucet HC & CA PL-1011 10-3007 Power Cord 120V – 1840 mm EL-5001-B Shown 19-1053 JG Equal Straight Connector ¼” PU-4010 Stainless Steel Gauze for PL-1013-G Faucet Ecostream Manual Page 26 - Revision: 11-13-2020...
  • Page 16 Stainless Steel Insert For 10-2701 PL-1088 Faucet Faucet Metal Clip for WL2200 ST-8282 Hot Tank Thermostat – 85C EL-0035-L00-00 (185F) Thermostat and Overload ST-8290 Metal Cover WL2100 Mini high voltage ST-8301 cover Ecostream Manual Page 27 - Revision: 11-13-2020...
  • Page 17 ECOSTREAM TOWER DRAWING AND PARTS LIST Wetted Drawing Ecostream Manual Page 28 - Revision: 11-13-2020...
  • Page 18 Recommend stocking 1 each CT-2002 per every 10 units ordered UV Lamp Ballast 120V 60Hz EL-0068- 10-3010 L00-00 Blue Faucet Nipple, with Stainless Steel Gauze 10-3048 PL-1013 Recommend stocking 2 each per every 10 units ordered Ecostream Manual Page 29 - Revision: 11-13-2020...
  • Page 19 Faucet HC & CA PL-1011 Front Panel for Drip Tray 12-5650 PL-1201-B Insert WL2100 Hot Water Caution Label 13.1 12-0001 Adhere to Front Panel for LP-7169 Drip Tray Insert 12-5285 AFL PCB Cover PL-1303 Ecostream Manual Page 30 - Revision: 11-13-2020...
  • Page 20 Guest Purchase JG Reducing Elbow from Connector 5/16” * ¼” PU-4007 John (PI211008S) Guest Purchase from JG Equal Tee Connector ¼” PU-4011 John (P10208S) Guest WL2000 FS Filter Bracket - ST-0275- Unpainted L00-00 Ecostream Manual Page 31 - Revision: 11-13-2020...
  • Page 21 Guest P/N PI1208S Special 12-8102 Wire Condenser CO-9027 Order 12-5673 WL2100 Gray Back Panel ST-8135-A 19-1069 Cold Tank Thermostat CT-2070-A PL-0326- 32.1 Cold Thermostat Cover Label L00-00 Socket for Plug Connection EL-0061- V0 Class L00-00 Ecostream Manual Page 32 - Revision: 11-13-2020...
  • Page 22 JG LLD PE Tube - Blue from 19-1054 O.D.1/4"John Guest P/N PE- PU-4031 John 08-BI-1000F-B Guest Silicon Tube 5/16” for Hot PL-4064- 10-7040 Water L00-00 10-3007 Power Cord 120V – 1840 mm EL-5001-B Shown Ecostream Manual Page 33 - Revision: 11-13-2020...
  • Page 23 JG ¼” Plug (PI0808S) PL-1172 Faucet Metal Clip for ST-8282 WL2200 Stainless Steel Gauze for PL-1013-G Faucet Stainless Steel Insert for 10-2701 PL-1088 Faucet WL850 Thermostat and Overload ST-8290 Metal Cover Ecostream Manual Page 34 - Revision: 11-13-2020...
  • Page 24 ECOSTREAM COUNTER TOP WATER FLOW DIAGRAM Ecostream Manual Page 35 - Revision: 11-13-2020...
  • Page 25 ECOSTREAM TOWER WATER FLOW DIAGRAM Ecostream Manual Page 36 - Revision: 11-13-2020...
  • Page 26 Turning the adjustment screw clockwise to lower the set point temperature. Do not adjust past the “Max Cold” position at 3:00 position to avoid freezing the cold tank. Turning the adjustment screw counter-clockwise to raise the set point temperature. Ecostream Manual Page 37 - Revision: 11-13-2020...