Download Print this page
WaterLogic BLUPURA Fizz 80 Preinstallation Manual

WaterLogic BLUPURA Fizz 80 Preinstallation Manual

Water treatment system
Hide thumbs Also See for BLUPURA Fizz 80:

Advertisement

Quick Links

Required with each BLUPURA Water Treatment
 
1 each – External Filter 
 
1 each – CO
 Regulator 
2
1 each – 10' C0
 ¼" OD Tubing 
2
(natural) 
2 each – 3/8" Quick 
Connect Connector 
BLUPURA Fizz 80 Manual 
PRE‐INSTALLATION PROCEDURE 
 
 
System. 
 
1 each – Chiller
1 each – External Filter
3 each – 10' Coils Water Tubing                
                 Blue 3/8" 
 
3 each – 10' Coils Insulation Tubing  
                 (not shown) 
1 each – 3/8" x ¼" quick Connect 
                                                            Page 19 ‐ Revision: 11‐2‐2018 
 
1 each – Water Pressure Regulator
1 each – 4 inch ¼" OD Tubing
1 each – 12 inch long  
Supply Hose ¼" ips x 3/8" Tube 
1 each – Water Shutoff Valve

Advertisement

loading

Summary of Contents for WaterLogic BLUPURA Fizz 80

  • Page 1 PRE‐INSTALLATION PROCEDURE      Required with each BLUPURA Water Treatment System.    1 each – External Filter        1 each – Chiller 1 each – CO  Regulator  1 each – Water Pressure Regulator 1 each – External Filter 1 each – 4 inch ¼” OD Tubing 1 each – 10’ C0  ¼” OD Tubing  3 each – 10’ Coils Water Tubing                                  Blue 3/8”  (natural)  1 each – 12 inch long     Supply Hose ¼” ips x 3/8” Tube  3 each – 10’ Coils Insulation Tubing                    (not shown)  2 each – 3/8” Quick  1 each – Water Shutoff Valve 1 each – 3/8” x ¼” quick Connect  Connect Connector  BLUPURA Fizz 80 Manual                                                              Page 19 ‐ Revision: 11‐2‐2018 ...
  • Page 2: Pre-Installation Procedures

    PRE‐INSTALLATION PROCEDURES          DANGER!  ELECTRICAL SHOCK HAZARD.   Only qualified personnel who have read and understand this entire manual should attempt to  install, or service this BLUPURA Water Treatment System, failure to do so could result in  death or serious injury.  DO NOT plug into an electrical supply until specifically instructed.              WARNING!  ALWAYS SANITIZE BEFORE USE.   Sanitize before use to eliminate any potential microbiological contaminates.                 CAUTION!  WEAR SAFETY GLOVES.  Wear safety gloves when handling the machine.  Metal edges are sharp and touching them  could result in a minor moderate injury.      UNPACKING      1. Remove the two straps securing unit to pallet.  2. Lift the internal cardboard box up and out of the cage.  3. Carefully check that the watercooler has not been damaged  during transport.  Any signs of damage must be reported to the  Shipping Agent immediately.    4. If the watercooler has been transported in a horizontal or  inclined position, a wait of 8 hours is needed before turning it on  so that the refrigeration circuit can function properly.        NOTE:  Packing Materials are made using recyclable material preventing potential negative  consequences for the environment and for health.        BLUPURA Fizz 80 Manual ...
  • Page 3 ELECTRICAL CONNECTION:      NOTE:  Recommended to plug system into GFI‐Protected outlet.  Be careful to not overload branch  electrical supply.     5. Connect the power cable to a socket.       6. Turn on Power switch on at back of unit.  I = ON.  The ice‐bank pump,  compressor and fan are now activated.      7. Pull Sparkling Dispense Tap to release air in the circuit and allow the pump to fill the  carbonator with water.  After approximately 1‐2 minutes, the sparkling pump stops.    SANITIZATION OF DRINKING CIRCUIT:       The sanitization of the drinking water circuit has to be performed:     Every time the BLUPURA Fizz 80 is installed   Every 6 months of operation   Each Change of filters   After system has been inoperative of 5 days or more.    8. Turn off incoming feed water (if connected).    9. Remove Filter Cartridge (if connected).    10. Mix ½ gallon of sanitizer per directions or use Bleach Solution (1 teaspoon = 1/6 oz. = 5 ml = ½  cap full) of household bleach (Sodium Hypochlorite 5 ‐ 10% Concentration) with 1/2 gallon of ...
  • Page 4 FILLING THE ICE BANK      15.  Fill ice bank with supply water (feed water).                16. Stop filling the Ice Bank once you reach the maximum level on the Ice  Bank level tube.  Ice Bank Level Tube          Maximum Level    Minimum Level              NOTE:  If the Ice Bank has been overfilled, water will come up  through the Drip Tray.                NOTE:  Do not move unit with water in the unit!     ...
  • Page 5   CONNECTING TO WATER SUPPLY (FEED WATER)    17. Ensure the incoming water pressure is between 14.5 and 51 PSI.  Incoming flow rate needs to  be .80 Gallons per minute minimum.  18. Install water line and filter to the incoming ¼” fitting on back of unit.  19. Once the tubes are attached, turn on water supply and dispense from Tap.  Ensure there are  no leaks.  CUT, SIZE AND CONNECT WATER AND CO2 PIPING TO FIT INSTALLATION          CAUTION!  WATER PRESSURE  Input or feed pressure must be 14.5 psi to 51 psi (.10 MPa – 0.35MPa).  Be aware of any  potential pressure surges caused by building/municipal pumping stations.  Water block  devices and external leak detectors are strongly recommended. Locate the unit as close to the  water supply and the electrical connections as possible to minimize risk.            CAUTION!  WEAR SAFETY GLOVES.  Wear safety gloves when handling the machine.  Metal edges are sharp and touching them  could result in a minor moderate injury.          CAUTION!  CHECK ALL PIPING AND CONNECTIONS FOR LEAKS  Check all input piping and connections for leaks before connecting to the machine.                          BLUPURA Fizz 80 Manual ...
  • Page 6   20. System should be chilled about 60 minutes later.    21. Dispense ½ Gallon of water from the sparkling tap, once system is chilled.    22. Allow to refill.    23. Unit is ready for use.    NOTE:  Complete Chilling of Ice Bank takes 1‐3 Hours.    INSTALLING OF C02 CYLINDER     WARNING!    Always connect C02 gas cylinder to a reducing valve or regulator.  Failure to do so could  result in an explosion with possible death or injury when the cylinder valve is opened.     WARNING!    Always secure gas cylinder in upright condition and away from heat.        NOTE:  Installation of C0  cylinder can only be done once the unit is connected to supply water  (feed water), has power and the ice‐bank tank has been filled.  24. Connect the cylinder through the pressure regulator to the   Inlet Pipe.    25. To increase the level of carbonation of the water, adjust the  screw by turning clockwise increases the level of carbonation.   We recommend that you do not exceed 4 bar (60 psi) of  pressure.       ...
  • Page 7   26. To  decrease  the  level  of  carbonation  of  the  water,  adjust  the  screw  by  turning  counter  clockwise.  REPURGE THE LINE FOR SPARKLING WATER    27. Place receptacle beneath Tap to catch dispensed water.      28. Allow water to run continuously until flow is clear of air.    NOTE:  The water will flow flat at first, then gradually become more sparkling as the line is purged  of still water.      COMPLETE INITIAL CHILL DOWN    29. Complete chilling of ice bank requires 1‐3 hours.    NOTE:  The machine should not be used as a water dispenser until chilling is complete.        BLUPURA Fizz 80 Manual                                                              Page 25 ‐ Revision: 11‐2‐2018 ...
  • Page 8: Maintenance Schedule

    MAINTENANCE    MAINTENANCE SCHEDULE    Process  Frequency  1. Upon Installation  Water Circuit Sanitization   2. When hydraulic components are replaced.    *Instructions are included in  3. Each filter change   this manual.  4. At a minimum must sanitize once a year.  Filter Change    1. Depending on the filtration capacity  *Instructions are in instruction  2. After each filter change, replace filter   manual present in every  cartridge.  Every sanitization and cartridge change.  Cleaning Internal Components  *Remove accumulation of dust, sand or other particulates  with a disposable cloth.  Every 6 Months  Cleaning of Refrigeration  *Remove accumulation of dust from the refrigeration  Condenser  condenser with a plastic brush.  Cleaning the mechanical water  filter of the Inlet Safety Valve    Depending on the hardness of supply water (feed water).  *Instructions are in instruction  manual present in every  cartridge.  Yearly.   Water Analysis  Check the bacteriological parameters to verify that the  water’s quality complies with current regulations. ...
  • Page 9 BLUPURA COUNTER TOP DRAINING INSTRUCTIONS    Draining Notes           WARNING!  STORE UNIT EMPTY.  ALWAYS SANITIZE BEFORE REUSE.  The unit must be completely drained and sealed before storing to avoid stagnation and reduce  microbial growth).        Drain the BLUPURA Water Treatment System for transportation.      1. To drain the ice bath, release sight tube on back of machine, rotate down to drain.                                  BLUPURA Fizz 80 Manual                                                              Page 27 ‐ Revision: 11‐2‐2018 ...
  • Page 10: Installation Procedures

    INSTALLATION PROCEDURES    Basic safety precautions should be followed, including the following:  Ensure all local, state, and federal laws and codes including health and safety guidelines are met  when installing Waterlogic Equipment.   Only qualified service technicians should attempt  installation and service of Waterlogic Equipment.    Always read the entire operating instructions  before using the appliance and save these instructions for future use.    DANGER! ELECTRICAL SHOCK HAZARD.  Always use a dedicated and properly grounded outlet.   Unit should be protected by ground‐fault circuit interrupter (GFCI) or residual current device (RCD)  having a rated residual operating current not exceeding 30mA.  Use only Waterlogic supplied  power cord. Never use extension cords or power strips to connect unit. Do not use if the power  supply cord is damaged. Always unplug from power supply prior to servicing.    WARNING! CONNECT TO POTABLE WATER SUPPLY.  This system is to be used for water only and  is not intended for use where water is microbiologically unsafe or with water of unknown quality  without adequate disinfection. System is designed for the supplemental bactericidal treatment of  public drinking water, or other drinking water, which has been tested and deemed acceptable for  human consumption by the state or local health agency having jurisdiction.  The system is designed  to reduce normally occurring non‐pathogenic or nuisance microorganisms only.  System is not  intended for treatment of contaminated water.    WARNING!  UNIT IS HEAVY.  TWO PERSON LIFT REQUIRED.  Transport unit empty and always use  material handling equipment or two people with proper lifting technique to reduce injury risk.             WARNING!  STORE AND TRANSPORT UNIT EMPTY.   ALWAYS SANITIZE BEFORE USE.  The unit must be completely drained and sealed before storing to avoid stagnation and reduce  microbiological contamination (potential bacterial growth).  Sanitize before use to eliminate any  potential microbiological contaminates.     CAUTION!  INDOOR USE ONLY.   Intended for household use only.  Never expose to direct sunlight,  heat sources, or ambient air temperature above 32°C (90°F) or below 16°C (61°F).  Install indoors  and keep unit away from excessive humidity.  Never expose to freezing temperatures.  Ensure  there is adequate clearance around the unit to allow refrigeration system condenser to dissipate  heat.  Warmer environments require more clearance around the unit.  Minimum clearance around  all surfaces of the machine is 4‐inches.      CAUTION!  USE A WATER PRESSURE REGULATOR. Waterlogic will not be responsible for injury or ...
  • Page 11 CAUTION!  WEAR SAFETY GLOVES.  Wear safety gloves when handling the machine.  Metal edges are sharp and touching them could  result in a minor moderate injury.    1. Fill the ice bath until indicated full in the sight tube on back of unit.      2. Attach the water supply line to the 3/8” supply water (feed water) inlet bulkhead fitting on the  back of the BLUPURA Water Treatment System.  Waterlogic requires the use of a water  pressure regulator.  Input or feed pressure must be 14.5 psi to 51 psi (.10 MPa – 0.35MPa).      3. Turn on the water supply and check for leaks.     4. Connect the power cord to a 120 Volt socket.  *The grounding of the unit is a legal  requirement.      5. Turn on Power Switch at back of unit.  I = ON     6. Fill the water circuit.  Hold a container under the still dispensing faucet, pull cold water knob  until a continuous flow of water is obtained.  Once a continuous flow is obtained, release the  dispensing button.  Cold tank is now full.      7. Move the BLUPURA Fizz 80 Water Treatment System into its final operating position.  Be sure  that a minimum of 2” clearance is maintained around both sides and the back of the BLUPURA  Fizz 80 Water Treatment System.      NOTE:  This is important to allow proper airflow and heat exchange of refrigeration system.     8. Level BLUPURA Water Treatment System using the adjustable feet to level if necessary.  Never  install on incline. ...