Signaling Standards Supported; Distance Limitations - Cisco 2612 Hardware Installation Manual

Hardware installation guide
Hide thumbs Also See for 2612:
Table of Contents

Advertisement

Chapter 2
Preparing to Install the Router
Table 2-3
Device Type
DTE
DCE
1. If pins protrude from the base of the connector, the connector is male.
2. If the connector has holes to accept pins, the connector is female.

Signaling Standards Supported

The synchronous serial ports available for the router support the following signaling standards:
EIA/TIA-232, EIA/TIA-449, V.35, X.21, and EIA-530. You can order a Cisco DB-60 shielded serial
transition cable that has the appropriate connector for the standard you specify. The documentation for
the device you want to connect should indicate the standard used for that device. The router end of the
shielded serial transition cable has a DB-60 connector, which connects to the DB-60 port on a serial
WAN interface card. The other end of the serial transition cable is available with a connector appropriate
for the standard you specify.
The synchronous serial port can be configured as DTE or DCE, depending on the attached cable (except
EIA-530, which is DTE only). To order a shielded cable, contact customer service. See the
Documentation" section on page
All serial ports configured as DTE require external clocking from a DSU/CSU or other DCE device.
Note
Although manufacturing your own serial cables is not recommended (because of the small size of the
pins on the DB-60 serial connector), cable pinouts are provided in the
Cable

Distance Limitations

Serial signals can travel a limited distance at any given bit rate; generally, the slower the data rate, the
greater the distance. All serial signals are subject to distance limits, beyond which a signal significantly
degrades or is completely lost.
Note
Only the serial WAN interface card supports bit rates above 128 Kbps.
Table 2-4
you might get good results at speeds and distances greater than those listed, if you understand the
electrical problems that might arise and can compensate for them. For instance, the recommended
maximum rate for V.35 is 2 Mbps, but 4 Mbps is commonly used.
OL-2171-06
Typical DTE and DCE Devices
Gender
1
Male
2
Female
Specifications.
lists the recommended maximum speeds and distances for each serial interface type; however,
Typical Devices
Terminal
PC
Modem
DSU/CSU
Multiplexer
xvii.
Cisco 2600 Series Routers Hardware Installation Guide
Preparing to Connect to a Network
"Obtaining
Cisco Modular Access Router
2-11