Machinery Directive. The person who compile technical file established within the EU: Name: IGM nastroje a stroje s.r.o. Address: Ke Kopanine 560, Tuchomerice, CZ-252 67 Tel.: +420 220 950 910 Email: sales@igmtools.com...
IGM Tools & Machinery strives to always deliver high-quality machinery. • Use only as described in this manual. Use only manufacturer’s The warranty is governed by the valid terms and conditions of IGM Tools & recommended attachments. Machinery available at www.igmtools.com.
• Do not use this machine for other than its intended use. If used for other • Maintain machinery with care. Follow instructions for lubricating and purposes, IGM nástroje a stroje s.r.o. and Laguna Tools Inc. disclaims any changing accessories.
Suspended dust particles and ignition sources. Do not operate the grounding conductor and a grounding plug. The plug must be plugged into dust collector in areas were explosion risks are high. Areas of high risk a matching outlet that is properly installed and grounded in accordance include, but are not limited to, areas near pilot lights, open flames, or other with all local codes and ordinances.
Page 6
3. Place each caster with the plate mount on the base. Take the hex bolt and washer and insert through the plate mount and thread into the base. Tighten each bolt. Do the same for the other three casters. Back side 3.
Page 7
6. Place the short side support labelled “L” in an upright position with the slant facing long side support. 11. Locate the support brace and place inside the two side supports. Note: Make sure the support is attached to the side supports closest to the motor.
Page 8
ATTACHING THE MOTOR AND DUST CHUTE TO THE FRAME 1. Place the motor and dust chute on their side. 2. Align the four holes, two shown at C, on the top of the side supports (A), with the four holes on the dust chute (B). 3.
USING A METAL BAG CLAMP You can also attach the plastic bag to the outside of the dust collector using the included metal bag clamp. 1. Place the metal bag clamp around the top of the plastic bag. Fold about 10 cm of plastic bag over the clamp.
6. Troubleshooting Machine does not start or a breaker trips. Possible Cause Possible Solution Power supply switched OFF or is faulty. 1. Ensure power supply is ON and has the correct voltage. Wall fuse/circuit breaker is blown/tripped. 2. Ensure adequate circuit size; install inlet restrictor, replace weak breaker. 3.Incorrectly wired motor connection.
Page 11
LOCK NUT 1/4” HEX BOLT 5/16”*3/4” FLAT WASHER 1/4”*OD13*1t SUPPORT BRACE HEX BOLT 1/4”*3/4” FLAT WASHER 5/16”*OD18*2t ADJUSTABLE BAND CLAMP Ø350mm HEX BOLT 5/16”*3/4” BLACK SNAP BAND Ø350mm PLUG 30*60mm SPRING BAG CLAMP Ø350mm BASE PLASTIC BAG Ø350mm*980mm www.igm.cz -11-...
Need help?
Do you have a question about the LAGUNA BFlux 1 and is the answer not in the manual?
Questions and answers