Troubleshooting An Optical Drive - Dell PowerEdge 860 Hardware Owner's Manual

Dell poweredge 860 servers: owners manual
Hide thumbs Also See for PowerEdge 860:
Table of Contents

Advertisement

9 Close the system. See "Closing the System" on page 47.
10 Reconnect the system to its electrical outlet, and turn on the system and attached peripherals.
11 Enter the System Setup program and check the system memory setting. See "Using the System Setup
Program" on page 29. If the amount of memory installed still does not match the system memory
setting, proceed to the next step.
12 Turn off the system and attached peripherals, and disconnect the system from its electrical outlet.
13 Open the system. See "Opening the System" on page 46.
NOTE:
Several configurations for the memory modules exist; see "Memory Module Installation Guidelines" on
page 68.
14 If a diagnostic test or error message indicates a specific memory module as faulty, swap or replace the
module. Otherwise, swap the memory module in socket 1 with a module of the same type and capacity
that is known to be good. See "Installing Memory Modules" on page 69.
15 Close the system. See "Closing the System" on page 47.
16 Reconnect the system to its electrical outlet, and turn on the system and attached peripherals.
17 As the system boots, observe any error message that appears and the diagnostic indicators on the front
of the system.
18 If the memory problem is still indicated, repeat step 12 through step 17 for each memory module
installed until the faulty memory module is replaced.
If the problem persists after all memory modules have been checked, see "Getting Help" on page 103.

Troubleshooting an Optical Drive

Problem
System cannot read data from a CD or DVD.
Optical drive indicator does not blink during boot.
Action
CAUTION:
Only trained service technicians are authorized to remove the system cover and access any of the
components inside the system. Before performing any procedure, see your Product Information Guide for
complete information about safety precautions, working inside the computer and protecting against electrostatic
discharge.
1 Try using a different CD or DVD in the optical drive.
2 Enter the System Setup program and ensure that the drive's IDE controller is enabled. See "Using the
System Setup Program" on page 29.
3 Run the appropriate online diagnostic test. See "Using Dell PowerEdge Diagnostics" on page 93.
4 Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.
5 Open the system. See "Opening the System" on page 46.
Troubleshooting Your System
89

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents