BEFORE YOU START Dear Customer, Thank you for purchasing BTL technology. All of us at BTL wish you every success with your system. We pride ourselves on being as responsive as possible to our customers’ needs. Your suggestions and comments are...
GENERAL CHARACTERISTICS OF THE DEVICE 1.1 INTENDED USE BTL-6000 High Intensity Laser is a non-invasive therapeutic device intended to emit energy in the infrared spectrum to provide topical stimulation of the biological tissue. This tissue stimulation results in local acceleration of healing, increase of metabolism, and analgesic reaction.
A time-saving feature of the BTL-6000 High Intensity Laser is the list of predefined programs stored in the memory of the main unit. Based on detailed research and practical use of the device, the well-organized predefined programs will provide recommendations for the treatment of various conditions.
There are several types of laser light generators used in the therapy of musculoskeletal apparatus. These laser light sources differ mainly in the various technical characteristics. BTL-6000 High Intensity Laser unit uses diode laser light source which emits light in the near infrared light spectrum.
Patients must be monitored for pain or discomfort throughout the entire procedure. In case the patient does not tolerate the therapy, discontinue the treatment immediately. BTL-6000 HIGH INTENSITY LASER – USER’S MANUAL | PAGE 10 OF 40...
Patients evaluated as skin type V. and VI. must be treated with special precautions. Monitoring of discomfort and unpleasant sensations of warming must performed during the whole treatment procedure with special care! BTL-6000 HIGH INTENSITY LASER – USER’S MANUAL | PAGE 11 OF 40...
The USB port serves only for service purposes such as upload of firmware; it is not designed for therapy use! 2.2 HANDPIECE OF THE BTL-6000 HIGH INTENSITY LASER safety ending spacer – 30 mm main body of the handpiece optical fibre BTL-6000 HIGH INTENSITY LASER – USER’S MANUAL | PAGE 12 OF 40...
– handpiece is permanently attached type and safety labelling communication link connector 2.4 FOOTSWITCH connection cable footswitch safety metallic cover footswitch bellows BTL-6000 HIGH INTENSITY LASER – USER’S MANUAL | PAGE 13 OF 40...
After switching the device on, the device will run a self-diagnostic of its internal circuits and its functions for about 10 to 15 seconds. If any fault is detected, the screen will display a warning message. If necessary; the control unit will lock itself into a “secure” mode. If this situation occurs, please contact your authorized BTL distributor. 2.5.1...
Page 15
Install the handpiece holder using the 2 torx screws M5x16 and the supplied torx screwdriver. The handpiece holder can be attached to either the left or the right side of the device. Insert the handpiece holder cup into the holder. BTL-6000 HIGH INTENSITY LASER – USER’S MANUAL | PAGE 15 OF 40...
The items on the touch screen can be pressed by a finger or by a touch-pen, which is included in the accessories of the device. The touch screen must not come in contact with any sharp objects, ball pens etc. BTL-6000 HIGH INTENSITY LASER – USER’S MANUAL | PAGE 16 OF 40...
The numbers of the particular programs will be prefixed with the letter “L”. For faster entry of the program number, use the numeric keypad. For more details see the Chapter Numeric keypad. BTL-6000 HIGH INTENSITY LASER – USER’S MANUAL | PAGE 17 OF 40...
Frequency of the pulsed laser light in hertz (Hz). This parameter is available only in the analgesic therapy mode. Pulse width Width of the single pulse emitted in milliseconds (ms). This parameter is available only in the single pulse therapy mode. BTL-6000 HIGH INTENSITY LASER – USER’S MANUAL | PAGE 18 OF 40...
Setting of the Pulse Width Pulse width can be set in the range from 2 ms up to 1000 ms. Setting is enabled when single pulse mode is active. BTL-6000 HIGH INTENSITY LASER – USER’S MANUAL | PAGE 19 OF 40...
For immediate discontinuation of the laser unit activity in case of emergency press the red laser stop emergency button on the front panel of the unit. BTL-6000 HIGH INTENSITY LASER – USER’S MANUAL | PAGE 20 OF 40...
Hold the footswitch until the pulse generation is complete. For another emission the footswitch control must be pressed again. For immediate discontinuation of the laser unit activity in case of emergency press the laser stop emergency button on the front panel of the unit. BTL-6000 HIGH INTENSITY LASER – USER’S MANUAL | PAGE 21 OF 40...
Here it is possible to scroll using the select knob. After selecting the required diagnosis, press the enter to get to the specific information on the clinical protocols. BTL-6000 HIGH INTENSITY LASER – USER’S MANUAL | PAGE 22 OF 40...
2.10.3.4 Colour Setting Allows setting of the colours of the controls displayed on the screen. There are 5 preset colour schemes available to choose from. BTL-6000 HIGH INTENSITY LASER – USER’S MANUAL | PAGE 23 OF 40...
The function allows creating personal account for every person who operates the device. Everyone has their own password to log in. 2.10.3.14 Firmware Upgrade Enables to upgrade the firmware version in the device. BTL-6000 HIGH INTENSITY LASER – USER’S MANUAL | PAGE 24 OF 40...
4. Press and hold the footswitch until the device indicates on the screen that the calibration is finished. 5. Release the footswitch and remove the handpiece from the calibration window. BTL-6000 HIGH INTENSITY LASER – USER’S MANUAL | PAGE 25 OF 40...
1x safety handpiece spacer 60 mm 1x safety handpiece spacer 10 mm transport case for the BTL-6000 High Intensity Laser door lock sensor trolley for BTL-6000 series BTL-6000 HIGH INTENSITY LASER – USER’S MANUAL | PAGE 26 OF 40...
Take care to avoid shocks or jarring movements to the device during transportation. This device should only be transported and stored under the conditions defined in the Chapter Technical Parameters. BTL-6000 HIGH INTENSITY LASER – USER’S MANUAL | PAGE 27 OF 40...
All persons present in the operatory must wear protective laser eyewear. Use only protective eyewear designed for the BTL-6000 High Intensity Laser. Periodically inspect the protective eyewear for any damage. Do not use damaged protective eyewear! ...
Page 29
BTL service department immediately. If the device is not used in accordance with this manual or if it is used when the device exhibits functional differences from those stated in this manual, then BTL is not responsible for any damage to or caused by the device. ...
Page 30
The device does not contain any components, except for the fuse, which can be repaired or replaced by the user. Do not remove the cover from the control unit. All repairs must be done by an authorized BTL service department.
Repeat the calibration. If Calibration procedure not the calibration fails again, contact completed successfully an authorized service of BTL devices. Error message System exception Follow the displayed instructions. BTL-6000 HIGH INTENSITY LASER – USER’S MANUAL | PAGE 31 OF 40...
Optical fibre handpiece Foot operated switch Symbol marking a connector sensitive to electrostatic discharge (ESD) Name and address of the manufacturer Date of manufacture Serial number Batch code Catalogue number BTL-6000 HIGH INTENSITY LASER – USER’S MANUAL | PAGE 32 OF 40...
The classification of the applied part applies to the handpiece including the safety spacer (see the Chapter 2.2). BTL-6000 HIGH INTENSITY LASER – USER’S MANUAL | PAGE 33 OF 40...
The BTL-6000 High Intensity Laser is intended for use in the electromagnetic environment specified below. The customer or the user of the BTL-6000 High Intensity Laser should assure that it is used in such an environment. Electromagnetic environment – guidance...
Page 36
Guidance and manufacturer’s declaration – electromagnetic immunity The BTL-6000 High Intensity Laser is intended for use in the electromagnetic environment specified below. The customer or the user of the BTL-6000 High Intensity Laser should assure that it is used in such an environment. IEC 60601...
Page 37
Guidance and manufacturer’s declaration – electromagnetic immunity The BTL-6000 High Intensity Laser is intended for use in the electromagnetic environment specified below. The customer or the user of the BTL-6000 High Intensity Laser should assure that it is used in such an environment. IEC 60601 Compliance Electromagnetic environment –...
BTL Industries Limited. BTL Industries Limited operates on a policy of continuous development. Therefore, we reserve the right to make changes and/or improvements to the product described in this manual without any prior notice.