BTL 4000 Series User Manual
Hide thumbs Also See for 4000 Series:
Table of Contents

Advertisement

BTL-4000
Series
U S E R ' S M A N U A L
GENERAL CHARACTERISTICS | Page 1 of 62
110DA03/03/2008EN

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 4000 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for BTL 4000 Series

  • Page 1 BTL-4000 Series U S E R ’ S M A N U A L GENERAL CHARACTERISTICS | Page 1 of 62 110DA03/03/2008EN...
  • Page 2 BTL-4000 system. Again, thank you for being a BTL customer. In the event of any problem, or if you require service, please make an initial call to your local distributor, who will decide whether to refer the problem to our office.
  • Page 3: Table Of Contents

    Save Therapy............................25 2.11 Interconnection of Units ..........................27 2.11.1 Interconnection of BTL 4000 Puls (COMBI) and Vacuum Unit BTL Vac ..........27 2.11.2 Interconnection of BTL-4000 Puls and BTL-4000 Sono ................. 27 2.11.3 Interconnection of BTL-4000 Puls, BTL-4000 Sono and BTL Vac ............28 2.11.4...
  • Page 4 Manufacturer ............................... 56 UNITS CONFIGURATIONS ..........................57 Table of Configurations of the Combined Devices BTL 4000 Series ............57 Table of Configurations of the Electrotherapy Devices BTL-4000 Puls ............60 Table of Configurations of the Ultrasound Therapy Devices BTL-4000 Sono..........61 Table of Configurations of the Laser Therapy Devices BTL-4000 Laser .............
  • Page 5: General Characteristics

    Prepare your own protocols and later invoke them from easily accessible option. With every BTL unit, you can purchase a cart specially designed for BTL products. Its versatile design allows you to conveniently store and use 1 or 2 physiotherapy units and a vacuum unit. The cart includes a range of accessory trays and baskets.
  • Page 6: Instructions For Use

    2 INSTRUCTIONS FOR USE 2.1 TOP PANEL 1. - 6 outputs for patient cables on the rear panel of the device, see chapter Rear Panel display diag key, for quick selection of diagnosis or programs prog key, for quick selection of therapy program man key, for manual setting of all therapy parameters menu key, to set date, time, language, display contrast, sounds, user options, etc.
  • Page 7: Rear Panel

    2.2 REAR PANEL 1 -6 patient outputs – for exact configuration, see table Configuration of Output Connectors mains switch, for switching the device on/off – positions I / 0. socket for connection of external power supply Adapter 60W / Adapter 90W warning label with parameters of power supply and input of the device INSTRUCTIONS FOR USE | PAGE 7 OF 62...
  • Page 8: Front Panel

    2.3 FRONT PANEL display of the remaining time of therapy for the first channel display of the remaining time of the therapy for the second channel (or current intensity in case the channel is only one) start / stop1 key, for starting or pausing the therapy on the first channel start / stop2 key, for starting or pausing the therapy on the second channel on / off switch –...
  • Page 9 Retain the original packaging to ensure future possible transportation of the device. Plug the device into the mains socket by means of the Adapter 60W / Adapter 90W power supply adapter (see chapter Technical Parameters). PLUG THE POWER SUPPLY ADAPTER DIRECTLY INTO THE MAINS SOCKET; DO NOT USE ANY MULTI- CONNECTION EXTENSION CABLE OR ADAPTOR.
  • Page 10 BTL-4110 Laser Optimal door acup. BTL-4710 Sono Optimal E input E output BTL-4210 Sono Optimal E input E output BTL-4810 S Combi Optimal E1opti BTL-4815 S Combi Optimal E1opti BTL-4810 L Combi Optimal door E1opti BTL-4815 L Combi Optimal door...
  • Page 11: Operating The Unit

    Selected channel Although most of the devices of the BTL-4000 Series can run more therapies at a time, only one channel can be controlled at the particular moment. That channel is called the "selected channel". The tab of the "selected channel"...
  • Page 12 INSTRUCTIONS FOR USE | PAGE 12 OF 62...
  • Page 13: Therapy Setting

    2.6 THERAPY SETTING 2.6.1 THERAPY FLOW CHART INSTRUCTIONS FOR USE | PAGE 13 OF 62...
  • Page 14: Welcome Screen And Selection Of Channels, Tabs And Accessories

    Examples of information on the tabs: tab of the selected E channel, to which no accessory is connected tab of the E channel, which is not selected, with connected accessory BTL-236-2 tab of the U generator , which is not selected, with connected ultrasound head;...
  • Page 15: Setting Of Therapy Parameters Via The Selection Of Diagnosis - "Diag" Key

    2.6.3 SETTING OF THERAPY PARAMETERS VIA THE SELECTION OF DIAGNOSIS – "DIAG" KEY To view the list of diagnoses press the diag key (8). Each channel tab has its own list of therapy protocols. The letter in front of each number corresponds to the type of selected therapy: E – electrotherapy; U – ultrasound; L –...
  • Page 16: Setting Of Therapy Parameters Via The Selection Of Program - "Prog" Key

    Press the prog (8) key to set the required program number. The program numbers generally correspond to the program numbers used in the traditional BTL physiotherapy line. The letter in front of each number corresponds to the type of therapy selected: E – electrotherapy; U – ultrasound; L – laser; M – magnetotherapy.
  • Page 17: Setting Of Therapy Parameters Manually Via The 'Man' Key

    2.6.5 SETTING OF THERAPY PARAMETERS MANUALLY VIA THE ‘MAN' KEY Press the man (9) key to select manual setting for the therapy. All therapy parameters can be set and saved as a user program or diagnosis. It is obvious that the therapy parameters screens of individual currents of electrotherapy, ultrasound therapy and laser therapy differ in dependence on the options which can be set in the particular moment.
  • Page 18: Therapy Parameters Screen

    2.6.6 THERAPY PARAMETERS SCREEN This screen opens after selection of therapy after pressing the diag (8), prog (9) or man (10) key, (see the chapter Therapy Setting Flow Chart). Before the start of therapy you can change all parameters. • SETTING THERAPY TIME The time of the therapy can be set only on the therapy parameters screen, either by activation of the time button and pressing of the enter key (13) after which the time setting dialog opens, or by fast selection using the...
  • Page 19: Course Of Therapy

    2.7 COURSE OF THERAPY 2.7.1 START, INTERRUPT AND END OF THERAPY To start therapy on the first channel (tab) press the start / stop1 key (24). To start therapy on the second channel press the start / stop2 key (25). Therapy can be started only if the display of the selected channel is displaying the therapy parameters screen.
  • Page 20: Running Therapy Screen

    2.7.2 RUNNING THERAPY SCREEN 2.7.3 ELECTROTHERAPY – SETTING DURING THERAPY • SETTING THE INTENSITY IN 4-ELECTRODE THERAPIES Making a therapy with four electrodes, you can set different intensities between each pair of electrodes. In case of 4-pole interference, the output intensity is set by the select / intensity (12) knob on both channels at the same time (the screen button 1+2 is pressed) or on each channel separately (the screen button 1 or 2 is pressed).
  • Page 21: Accessories / Applicators - Visual Signalization

    •rapid blinking – wrong contact of head with patient's tissue, therapy paused; contact must be re- established to continue therapy BTL-448: laser probes 635 nm and 830 nm – green pilot light and focusing beam: •blinking in rhythm of generated laser or continuous light – the device is generating laser radiation, during generation the device indicates occurrence of laser radiation by acoustic signal BTL-445: laser clusters: red, infrared and combined –...
  • Page 22: Indication Of Operation - Energy On Operation

    BTL vac: vacuum unit for electrotherapy – see separate manual for BTL vac unit. For detailed information please refer to the leaflet which is enclosed to each accessory supplied. BTL-239-1: disc magnetic applicator – blue pilot light signals: •slow blinking – accessories prepared for therapy, therapy settings screen displayed.
  • Page 23 Some types of the generated currents do not allow monitoring of the contact with the patient. In such cases the crossed-out figure is displayed, regardless of the user setting of detection. Ultrasound Therapy Generation of ultrasound energy by ultrasound head BTL-237 is indicated: • on the screen: –...
  • Page 24: Therapy Parameters

    – by value of intensity and remaining time • on the magnetic applicator BTL-239 – by blue pilot light. 2.8 THERAPY PARAMETERS Therapy parameters are variable. Only the parameters that characterize the therapy and that can be set in manual mode are displayed - by pressing the man (10) key.
  • Page 25: Therapy Saving

    2.10 THERAPY SAVING Pressing the save button on the screen, the user can save the particular therapy setting under a name of diagnosis and number of program. 2.10.1 SAVE THERAPY Therapy can be saved always after setting of the therapy parameters – i.e. from the therapy parameters screen. The following information is saved with each therapy: Electrotherapy: •...
  • Page 26 The number of the saved program falls within the interval from 8000 to 8999. and adds the letter of the corresponding generator (E for electrotherapy and combined therapies, U for ultrasound therapies, L for laser therapies and M for magnetotherapy). The unit suggests the lowest available number (from the range of 8000-8999) and adds the letter of the corresponding generator (E for electrotherapy and combined therapies, U for ultrasound therapies, L for laser therapies and M for magnetotherapy).
  • Page 27: Interconnection Of Units

    INTERCONNECTION OF BTL 4000 PULS (COMBI) AND VACUUM UNIT BTL VAC Combine any BTL-4000 Puls or Combi unit with the vacuum unit BTL vac to apply electrotherapy currents by means of suction cup electrodes. Adjustable vacuum pressure ensures simple and convenient attachment of patient electrodes, especially on parts of the body hard to reach with classic electrodes.
  • Page 28: Interconnection Of Btl-4000 Puls, Btl-4000 Sono And Btl Vac

    If you want to apply only electrotherapy with such interconnected devices, it is no problem. Uncheck the option "with electro" on the BTL-4000 Sono device, and the electrotherapy electrodes are automatically connected to the electrotherapy output. Connectors E-input and E-output are interconnected inside the ultrasound device even if the BTL-4000 Sono device is off.
  • Page 29: Setup And Operation Of Combined Therapy In Individual Devices

    2.11.4 SETUP AND OPERATION OF COMBINED THERAPY IN INDIVIDUAL DEVICES After checking for correct interconnection of the electrotherapy and ultrasound units, select a diagnosis or program that utilizes combined therapy. Select these separately on the electrotherapy and on the ultrasound units.
  • Page 30: Device Menu

    Make sure the installed accessory is connected directly, not via interface cable and vacuum or BTL-4000 Sono devices. This will help decrease electromagnetic interference, which could cause improper reading of memory data.
  • Page 31: Unit Settings

    The units as standard come with this function disabled. If the unit includes a laser generator - BTL-4000 Laser, BTL-48xx L, BTL-48xx xL, you cannot disable the password code (in compliance with the applicable standards). In this case, the four-digit code is factory-set to 0000.
  • Page 32: Setting Of Display Contrast

    3.2.4 SETTING OF DISPLAY CONTRAST After selection of this menu you can set the optimum contrast (readability) of the display by the select/intensity knob (12). Since the display contrast depends on many factors (e.g. temperature of the display), there is also another fast and direct way of setting the contrast.
  • Page 33: Service Functions

    3.2.14 SERVICE FUNCTIONS • SCAN DISK Checks the file system in the unit for possible errors. Recommended for use in case of lack of memory, if the unit refuses to save data, or if you think that some data have been lost. •...
  • Page 34: User Settings Option

    4 USER SETTINGS OPTION Press menu, select the user settings option - opens a screen allowing access to special features of the unit, as well as to data saved by the user. The following items can be selected: • user sequences •...
  • Page 35 For the electro generator it is possible to select sequence in the therapy parameters screen (in the manual mode). For the laser generator, laser sequence is in the therapy parameter screen, accessible by means of the next key (from the manual mode). Creation of a new sequence for the electro generator is displayed in the following diagram.
  • Page 36: Parameters Of Sections In Sequence

    4.1.2 PARAMETERS OF SECTIONS IN SEQUENCE A sequence consists of a few currents / programs that are called sections. Parameters of sections must be set when creating a sequence. Each program includes basic current parameters such as frequency, pulse length, modulation, etc. For more information, please refer to the chapter Save Therapy.
  • Page 37: User Diagnoses / Programs

    4.2 USER DIAGNOSES / PROGRAMS Use this feature to run user designed therapies, to edit and delete their parameters and names. It is very similar to the creation of a new diagnosis / program – see the chapter Therapy Saving. On each channel tab, you can see only those therapies that were created on this tab.
  • Page 38: Accessories

    5.1 POWER SUPPLY ADAPTER 60W / ADAPTER 90W The devices of the BTL-4000 series can be connected to the mains exclusively via the supplied power supply Adapter 60W or Adapter 90W. Adapter 90W is more powerful and is used only for the connection of specific device configurations.
  • Page 39: Lithium Battery

    The device contains a lithium battery for backing up the date and time. The type of battery is stated in the chapter Technical Parameters. Replacement is provided by the authorized service of BTL devices. 5.4 ACCESSORIES COMMON FOR ALL UNITS •...
  • Page 40: Accessories For Ultrasound Therapy

    - BTL-239-4 • multi disc applicator - BTL-239-5 • linear applicator - BTL-239-6 • solenoid applicator ø70cm with couch- BTL-239-8 interface cable for connection of old type of applicators from BTL-09 • • fixation belts ACCESSORIES | PAGE 40 OF 62...
  • Page 41: Maintenance And Safety Instructions

    30 months. The inspection and recalibration is performed by the authorized BTL service department on the basis of the user's order. If the inspection is not done within the stated term, the manufacturer does not guarantee the technical parameters or safe operation of the product.
  • Page 42: Safety

    If you do not determine the source of uncertainty after thorough study of the Manual, contact the BTL service department. If the equipment is not used in accord with this Manual or is used even if it shows functional differences from this Manual, the user is responsible for the damage caused by the equipment.
  • Page 43 • The equipment does not contain any components which can be repaired by the user. Do not remove any covers from the equipment. All repairs should be done by the authorized BTL service department. • Don’t connect equipment to the patient when it is still connected to the computer (via service connector).
  • Page 44 • For therapy, use only the BTL ultrasound gel; the head is not tested for other gels or oils and their use could damage the head. If you still want to use other gels, we recommend them to be only water-based gels.
  • Page 45 Safety precautions for laser: • Mark the laser workplace with the respective warning notices and connect the door switch. • Equip the laser workplace with an operating code which must be approved by a competent health officer. • When using a laser probe with an output of 200 mW or more (300 mW, 400 mW) and if the laser power is set higher than 150 mW, the duration of therapy must not exceed 15 min.
  • Page 46: Contraindications

    6.2 CONTRAINDICATIONS The list of contraindications the cases when the manufacturer does not recommend applying the selected therapy. If a specialised medical workplace decides to apply the therapy in spite of it, they bear all the responsibility for this action. 6.2.1 CONTRAINDICATIONS FOR ELECTROTHERAPY •...
  • Page 47: Contraindications For Ultrasound

    6.2.2 CONTRAINDICATIONS FOR ULTRASOUND • Active tuberculosis • Allergies to used ultrasound gels • Applications on peripheral nerves (located on the bone, close to skin surface) • Applications on glands with inner secretion • Applications on areas around the eyes, brain, spinal cord •...
  • Page 48: Contraindications For Magnetotherapy

    Children – growth discs of bones (epiphysis) WARRANTY The Manufacturer of this product guarantees the product is free of defects in workmanship and material for the period and conditions defined in the BTL General Service Conditions. MAINTENANCE AND SAFETY INSTRUCTIONS | PAGE 48 OF 62...
  • Page 49: Technical Parameters

    7 TECHNICAL PARAMETERS 7.1 TECHNICAL PARAMETERS OF THE BTL-4000 SERIES DEVICES Device Type: BTL-4000 Series – physiotherapy Display: •dimensions: diagonal: 10.922 cm (4.3”) •resolution: 480 x 272 Low battery indication: on the display Design Weight – device only 2.9 kg...
  • Page 50: Technical Parameters Of Power Supply Adapter 60W / Adapter 90W

    Therapy duration For electro and laser therapies 0 to 100 minutes For ultrasound therapies 0 to 30 minutes For magnetotherapies 0 to 100 minutes Step of setting 1 second Accuracy of therapy time ± 2 % of the set value Accuracy of time values 5 seconds per day 7.2 TECHNICAL...
  • Page 51: Basic Parameters Of Electrotherapy Generator

    7.3 BASIC PARAMETERS OF ELECTROTHERAPY GENERATOR Output current* max. 140 mA (maximum instantaneous value) Output current - HVT** max. 4 A (maximum instantaneous value) Output current - microcurrents** max. 999 µA (maximum instantaneous value) Output voltage max. 130 V (maximum instantaneous value) Output voltage - HVT** max.
  • Page 52: Basic Parameters Of Laser Generator

    10mA active level settable positive / negative logic Adjustable values Frequency*** 0 – 10000 Hz with laser probe BTL-448 0 – 500 Hz with laser cluster BTL-445 ± 3 % of the stated value accuracy of frequency Dose* 0.1 – 100.0 J/cm accuracy of dose ±20% (according to IEC 60601-2-22)
  • Page 53: Technical Parameters Of Ultrasound Heads

    7.7 TECHNICAL PARAMETERS OF ULTRASOUND HEADS BTL-237-1-13 – small head Effective radiation area (ERA) ± 20% ERA (EN 61689) 0.7 cm ERA (21 CFR 1050) ± 20% 0.9 cm Maximum effective intensity ± 20% 3 W/cm 2.1 W ± 20%...
  • Page 54: Technical Parameters Of Laser Clusters

    Type: BTL-448-40IC Output power: 400 mW ± 20 % Wavelength: 830 nm Class*: Beam: collimated Aperture: Ø 4.4 mm 0.015 rad ± 0.005 rad BNR: NOHD**: 19.2 m * Laser class is classified according to IEC 60601-2-22:1995 and IEC 60825-1:1993/A2:2001.
  • Page 55: Technical Parameters Of Magnetic Applicators

    7.6 mT (76 G) These mentioned parameters for applicators are basic. The exact values and shape of the magnetic field – please see 2 part of manual – BTL-4000 Magnetotherapy User’s Guide. 7.11 APPLICABLE STANDARDS Name IEC, EN, ISO, MDD Medical electrical equipment.
  • Page 56: Interconnection Of Devices

    The contents of this document are provided "as is". Except as required by the applicable law, no warranties of any kind, either expressed or implied, are made in relation to the accuracy, reliability or contents of this document. BTL Industries Limited reserves the right to revise this document or withdraw it at any time without prior notice.
  • Page 57: Units Configurations

    8 UNITS CONFIGURATIONS 8.1 TABLE OF CONFIGURATIONS OF THE COMBINED DEVICES BTL 4000 SERIES 4810S 4810L 4800SL 4810S 4810L 4800SL Type: Professional Professional Professional Optimal Optimal Optimal mains supply built-in accumulator manual mode predefined programs predefined diagnoses user programs ultrasound head 1MHz ultrasound head 1/3MHz el.
  • Page 58 1MHz ultrasound head 1/3MHz el. patient cables – basic el. p. cab. with visual detection possibility to connect BTL-vac electrotherapies ultrasound therapies laser therapies magnetic therapies number of simultaneously running therapies number of simultaneously running electrotherapies.
  • Page 59 2MHz el. patient cables – basic el. p. cab. with visual detection possibility to connect BTL-vac electrotherapies ultrasound therapies magnetic therapies laser therapies number of simultaneously running therapies number of simultaneously...
  • Page 60: Table Of Configurations Of The Electrotherapy Devices Btl-4000 Puls

    8.2 TABLE OF CONFIGURATIONS OF THE ELECTROTHERAPY DEVICES BTL-4000 PULS 4610 4615 4620 4625 4610 4615 4620 4625 Type: Professional Professional Professional Professional Optimal Optimal Optimal Optimal mains supply built-in accumulator manual mode pre-defined programs pre-defined diagnoses user programs ultrasound head 1MHz ultrasound head 1/3MHz el.
  • Page 61: Table Of Configurations Of The Ultrasound Therapy Devices Btl-4000 Sono

    2 MHz detection of contact continuous continuous continuous continuous continuous mode of operation pulse mode of operation duty factor 8.4 TABLE OF CONFIGURATIONS OF THE LASER THERAPY DEVICES BTL-4000 LASER 4110 4110 Type: Professional Optimal mains supply built-in accumulator...
  • Page 62: Table Of Configurations Of The Magnetotherapy Devices Btl-4000 Magnet

    8.5 TABLE OF CONFIGURATIONS OF THE MAGNETOTHERAPY DEVICES BTL- 4000 MAGNET 4920 4920 Type: Professional Optimal mains supply built-in accumulator manual mode number of magnetotherapies user programs predefined diagnoses preset programs language versions sound schemes recent therapies number of simultaneously...