Polon-Alfa DOT-3000 Installation And Maintenance Manual

Polon-Alfa DOT-3000 Installation And Maintenance Manual

Universal smoke and heat detector

Advertisement

Quick Links

UNIVERSAL SMOKE AND HEAT DETECTOR
DOT-3000
POLON 3000 FIRE ALARM SYSTEM
_________________________________________________________________________________
INSTALLATION AND MAINTENANCE MANUAL
IK-E403-001-GB
Change 1
[Type here]
DOP-3000 BEAM SMOKE DETECTOR

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DOT-3000 and is the answer not in the manual?

Questions and answers

Summary of Contents for Polon-Alfa DOT-3000

  • Page 1 UNIVERSAL SMOKE AND HEAT DETECTOR DOT-3000 POLON 3000 FIRE ALARM SYSTEM _________________________________________________________________________________ INSTALLATION AND MAINTENANCE MANUAL IK-E403-001-GB Change 1 [Type here] DOP-3000 BEAM SMOKE DETECTOR...
  • Page 2 IK-E403-001-GB Change 1 The DOT-3000 universal smoke and heat detector, which is the subject to this IMM meets the essential requirements of the following Regulations of the European Parliament and of the Council (EU) and European Union Directives: CPR CPR/305/2011 Regulation (EU) of the European Parliament and of the Council of 9 March 2011 laying down harmonised conditions for the marketing of construction products repealing Council Directive 89/106/EEC;...
  • Page 3: Table Of Contents

    IK-E403-001-GB Change 1 Table of contents 1 PURPOSE ........................... 4 2 TECHNICAL SPECIFICATIONS ....................... 4 3 DESIGN ............................4 4 PRINCIPLE OF OPERATION ......................4 5 DETECTOR OPERATING MODES ....................6 6 OPERATING CONDITIONS AND MAINTENANCE ................8 7 INSTALLATION ......................... 10 8 SAFETY CONDITIONS ........................
  • Page 4: Purpose

    POLON 3000 fire alarm control panels. All detectors are equipped with an internal short-circuit isolator. In the following part of the manual, the DOT-3000 universal smoke and heat detector will be referred to as the "detector". 2 TECHNICAL SPECIFICATIONS Operating voltage 16.5 V ÷24.6 V...
  • Page 5 The detector is equipped with an internal short circuit isolator that cuts off an efficient detection line from the neighbouring shorted section what enables further undisturbed detector operation. DOT-3000 is an analogue detector with a digital self-regulation mechanism, i.e. it maintains a constant sensitivity during measuring chamber contamination progress. After exceeding the assumed threshold...
  • Page 6: Detector Operating Modes

    Sensitivity of smoke sensors: - Normal: (0), - Reduced by 20 %: (1). Fault and technical alarms of switched off sensors are not transmitted to the control panel. DOT-3000 UNIVERSAL SMOKE AND HEAT DETECTOR...
  • Page 7 IK-E403-001-GB Change 1 Depending on the sensors activated, the suitability of the detector for fire detection is specified in the table below. Sensors Sensor On Test fire detection Dependence Compliance of the operating mode with standards Mode OUV OIR 0 - 3 TF1 TF2 TF3 TF4 TF5 TF6 TF7 TF8 TF9 EN 54-5, EN 54-7, +++ ++ ++ +++ +++ ++ +++ +++ +++...
  • Page 8: Operating Conditions And Maintenance

    LED is slightly to the right of the glass; d) cover turned to the left. DOT-3000 UNIVERSAL SMOKE AND HEAT DETECTOR...
  • Page 9 IK-E403-001-GB Change 1 After assembly, the detector should be checked using a smoke imitator (not producing heat) and then using a temperature imitator (not producing smoke). NOTE - If cleaning does not give the desired result, the detector should be sent to the manufacturer for repair.
  • Page 10: Installation

    G-40 socket. Additional optical signalling of a single detector or a group of detectors can be obtained by attaching the WZ-31 activation indicator: - standard configuration of the activation indicator, Fig.7.1 Detector operating in zero additional mode WZ wiring diagram DOT-3000 UNIVERSAL SMOKE AND HEAT DETECTOR...
  • Page 11: Safety Conditions

    Maintenance works and periodic inspections must be carried out by authorized personnel of companies trained by POLON-ALFA. All repairs must be carried out by the manufacturer. POLON-ALFA is not responsible for the operation of equipment maintained and repaired by unauthorized personnel. 8.2 Working at Height Any detector installation works carried out at height must be executed with particular care utilising tools and machinery in good working condition.
  • Page 12: Storage And Transportation

    The temperature during transport should not be lower than -40 °C and above +70 °C, and the relative humidity should not exceed 95 % at +45 °C or 80 % at +70 °C. IK-E403-001-GB/09.2024 DOT-3000 UNIVERSAL SMOKE AND HEAT DETECTOR...
  • Page 13 IK-E403-001-GB Change 1...

Table of Contents