Comply with all applicable codes and safety regulations. Failure to do so may result in damage, injury or death. CERTIFICATIONS: CE, CSA, UL Standard for Industrial Control Equipment – ANSI/UL 508, Certified to CAN/CSA-C22.2 No. 14 Brite-X 1000S Operating Instructions Document no. 10040904 Rev 2.7...
The output is provided as an analog, 0 – 5 V signal with high, 20mV resolution. A PLC or a computer can process the analog output, or the reflected level can be set on the Brite-X 1000S to trigger a discrete output.
5. Various adjustments may be made to increase or decrease sensitivity; refer to the Sections Calibration Adjustment and LED Intensity Level. Refer to Section: Threshold, to alter threshold setting. 6. User programmable parameters are discussed in detail in the following sections. Brite-X 1000S Operating Instructions Document no. 10040904 Rev 2.7...
(as determined by the hysteresis setting), the red LED will extinguish and the discrete output will de-activate. The threshold setting allows the user to select the detection level. The default setting is 15. Brite-X 1000S Operating Instructions Document no. 10040904 Rev 2.7...
Page 6
The output remains active as long as the intensity level exceeds the threshold, in high-speed applications it may be useful to use the Extend Output Pulse feature to lengthen the signal duration to meet acquisition requirements of the PLC. Brite-X 1000S Operating Instructions Document no. 10040904 Rev 2.7...
Page 7
Since the sensor uses reflected light from the sugar to determine relative variations in color, it is important to place the sensor in a location where the distance variation is minimal. Brite-X 1000S Operating Instructions Document no. 10040904 Rev 2.7...
Page 8
Below is a BriteX installation showing the customer designed mounting apparatus and sugar leveling wedge providing a fixed measurement distance between the sensor and the sugar surface. Please note that EMX Industries provides only the sensor, mounting and leveling hardware is the customer’s responsibility.
Pin 1 Brown Power 10 to 24VDC Pin 2 White Discrete output, PNP/NPN, NO/NC Pin 3 Blue Ground Pin 4 Black Analog output 0 to 5V DC Pin 5 Yellow Remote lock Brite-X 1000S Operating Instructions Document no. 10040904 Rev 2.7...