Download Print this page
Gima HOSPI PLUS Instruction Manual

Gima HOSPI PLUS Instruction Manual

Suction aspirator

Advertisement

Quick Links

PROFESSIONAL MEDICAL PRODUC TS
ASPIRATORE CHIRURGICO HOSPI PLUS
HOSPI PLUS SUCTION ASPIRATOR
ASPIRATEUR HOSPI PLUS
CHIRURGISCHER ABSAUGER HOSPI PLUS
ASPIRADOR QUIRÚRGICO HOSPI PLUS
ASPIRATOR CHIRURGICZNY HOSPI PLUS
ASPIRATORUL CHIRURGICAL HOSPI PLUS
ΧΕΙΡΟΥΡΓΙΚΟΣ ΑΝΑΡΡΟΦΗΤΗΡΑΣ HOSPI PLUS
28200 - 20201 - 28203 -28204
Gima S.p.A.
Via Marconi, 1 - 20060 Gessate (MI) Italy
gima@gimaitaly.com - export@gimaitaly.com
www.gimaitaly.com
Made in Italy
0476

Advertisement

loading
Need help?

Need help?

Do you have a question about the HOSPI PLUS and is the answer not in the manual?

Questions and answers

Summary of Contents for Gima HOSPI PLUS

  • Page 1 PROFESSIONAL MEDICAL PRODUC TS ASPIRATORE CHIRURGICO HOSPI PLUS HOSPI PLUS SUCTION ASPIRATOR ASPIRATEUR HOSPI PLUS CHIRURGISCHER ABSAUGER HOSPI PLUS ASPIRADOR QUIRÚRGICO HOSPI PLUS ASPIRATOR CHIRURGICZNY HOSPI PLUS ASPIRATORUL CHIRURGICAL HOSPI PLUS ΧΕΙΡΟΥΡΓΙΚΟΣ ΑΝΑΡΡΟΦΗΤΗΡΑΣ HOSPI PLUS 28200 - 20201 - 28203 -28204 0476 Gima S.p.A.
  • Page 2: Important Safety Rules

    ENGLISH HOSPI PLUS SUCTION ASPIRATOR is a surgical aspirator power-fed at 230V ~ / 50Hz, to be used for suc- tioning body liquids (such as mucus, phlegm and blood) provided with 4 antistatic wheels, two of which with braking device, and a pulling handle. This equipment is designed for easy transport and continuous utilization.
  • Page 3: Technical Characteristics

    • The device must not be used for suction of explosive, corrosive or easily flammable liquids. • HOSPI PLUS SUCTION ASPIRATOR is not suitable for MRI. Do not introduce the device in MRI environments. TECHNICAL CHARACTERISTICS TYPOLOGY (MDD 93/42/EEC) Class IIa Medical Decice...
  • Page 4: Cleaning The Main Unit

    ENGLISH CLEANING THE MAIN UNIT To clean the device external parts always use a cotton cloth dampened with detergent. Don’t use abrasive or solvent detergents. ATTENTION: During cleaning make sure that liquids do not come into contact with the membrane keyboard (only in versions with footswitch and flux deviator) and adjacent areas as this would damage the component, with possible infiltration of the liquid inside the device..
  • Page 5 ENGLISH Conical fitting: the number of cycles of sterilization and the number of cleaning cycles is strictly linked to the employment of the said component. Therefore, after each cleaning cycle, it is up to the final user to verify whether the fitting is suitable for reuse. The component must be replaced if there are visible signs of decay in the material constituting the said component.
  • Page 6: Maintenance

    ENGLISH MAINTENANCE The HOSPI PLUS SUCTION ASPIRATOR suction equipment does not need maintenance or lubrication. It is, however, necessary to inspect the unit before each use. With regard to training, given the information contained in the user manual and since it is easy to understand the said device, it doesn’t appear to be necessary. The device must be checked before each use in order to detect malfunctions and / or damage caused by transport and / or storage.
  • Page 7 ENGLISH INSTRUCTIONS • The working position must be such as to allow one to reach the control panel and to have a good view of the empty indicator, the jar and the antibacterial filter. • If the device is to be transported from one place to another, to prevent the liquid collection jar from falling and consequently theliquid from spilling, removing the jar from the device is recommended.
  • Page 8 ENGLISH WARNING: The power supply cable plug is the element of separation from the electrical mains system: even if the units equipped with a special on / off switch button, the power supply plug must be kept accessible once the device is in use so as to allow a further method of disconnection from the mains supply system. MULTIPURPOSE BAR- MPR SYSTEM The device is equipped with a multipurpose bar to easily change accessories (such as rings of different diameters for different collection vessel capacities, safety traps, cannula holders or standard 30x10 mm stainless steel...
  • Page 9: Risk Of Electromagnetic Interference And Possible Rem- Edies

    Standard. CISPR group and category classification: group 1, category B. The HOSPI PLUS surgical aspirator is an electro-medical device that requires particular precautions regarding electro-magnetic compatibility and which must be installed and commissioned according to the electro- magnetic compatibility information supplied. Portable and mobile radio communication devices (mobile phones, transceivers, etc.) may interfere with the medical device and should not be used in close proximity...
  • Page 10 Guidance and manufacturer’s declaration – Electromagnetic Emissions The HOSPI PLUS SUCTION ASPIRATOR is intended for use in the electromagnetic environment specified below. The customers or the user of the HOSPI PLUS SUCTION ASPIRATOR should assure that it’s used in such an environment. Emissions Test...
  • Page 11 Guidance and manufacturer’s declaration – Immunity Emissions The HOSPI PLUS SUCTION ASPIRATOR is intended for use in the electromagnetic environment specified below. The customers or the user of the HOSPI PLUS SUCTION ASPIRATOR should assure that it’s used in such an environment. Immunity Test...
  • Page 12 The surgical aspirator is intended for use in an electromagnetic environment in which radiated RF disturbances are con- trolled. The customer or the user of the HOSPI PLUS SUCTION ASPIRATOR device can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communication equipment (transmit- ters) and the HOSPI PLUS SUCTION ASPIRATOR device, as recommended below, according to the maximum output power of the communications equipment.
  • Page 13 Disposal: The product must not be disposed of along with other domestic waste. The users must dispose of this equipment by bringing it to a specific recycling point for electric and electronic equip- ment. GIMA WARRANTY TERMS The Gima 12-month standard B2B warranty applies.

This manual is also suitable for: