Page 1
50 Hz e-IXP Series CEntRIfugal SInglE StagE End-SuCtIon PumP dESIgnEd In ComPlIanCE wIth ISo 2858 and ISo 5199 StandaRdS Cod. 191002661 Rev. B Ed.08/2021...
Page 2
Lowara, HYDROVAR, Xylect are trademarks or registered trademarks of Xylem Inc. or one of its subsidiaries. All other trademarks or registered trademarks are property of their respective owners The Bluetooth® word mark and logos are registered trademarks owned by Bluetooth SIG, Inc. and any use of such marks by Xylem Inc. is under license.
SUMMARY GENERAL INTRODUCTION ............................ IDENTIFICATION CODE ............................RATING PLATE ..............................LIST OF MODELS AT 50 Hz, 2 POLES ........................ LIST OF MODELS AT 50 Hz, 4 POLES ........................ LIST OF MODELS AT 50 Hz, 6 POLES ........................ GENERAL TECHNICAL MECHANICAL DATA....................... ELECTRIC PUMP CROSS-SECTION AND MAIN COMPONENTS................
e-IXP SERIES GENERAL INTRODUCTION The new e-IXP is single stage, volute casing end suction pump built to comply with ISO 2858 and ISO 5199 Standards. The new e-IXP pump is capable of meeting the pumping needs of customers in virtually all major markets and can be supplied in multiple materials of constructions and with various shaft sealing configurations.
Page 7
The more compact e-IXPS is perfect on OEM applications or in case of space constrains. • SIMPLICITY: A standardized pump according to ISO 5199 and ISO 2858 suits the retrofit market. The modular design optimizes spare parts management and reduces lead time. Thanks to Xylem optimyze operating data are available for maintenance logging. •...
e-IXP SERIES IDENTIFICATION CODE X P C H 2 0 0 1 5 0 3 1 5 A 1 1 0 0 W 2 5 B D N 2 S 1 G Motor power [3 to 4 digits] kW x 10 or Pump Type [3 digits] actual impeller [IXP] = series name...
e-IXP SERIES RATING PLATE Year LEGEND 1 - Electric pump unit / pump type 2 - Electric pump unit / pump code 3 - Flow range 4 - Head range 5 - Nominal or maximum pump power 6 - Speed 7 - Serial number, or order number + order position number 9 - Full impeller diameter (only filled in for trimmed impellers) 10 - Trimmed impeller diameter (only filled in for trimmed impellers)
e-IXP SERIES GENERAL TECHNICAL MECHANICAL DATA SHAFT SLEEVE DIAMETER IMPELLER SHAFT DIAMETER [mm] [mm] SIZE DIAMETER [mm] N. OF VANES 40-25-160 53,0 40-25-200 53,0 50-32-160 64,0 50-32-200 59,0 50-32-250 72,0 65-50-160 74,4 65-40-200 73,7 65-40-250 80,0 65-40-315 75,0 80-65-125 93,5 12,0 80-65-160 84,4...
Page 14
e-IXP SERIES AVAILABLE MATERIALS Various material configurations are available to fit the needs of different pumped mediums and applications requirements. Below are the specifics regarding the material configurations and their availability for the different pump sizes. MATERIAL IXP The material identification codes are the same used in the pump description (see page 8). PUMP MATERIAL CODE PART STANDARD...
e-IXP SERIES MECHANICAL SEALS IXPS UNBALANCED UNBALANCED UNBALANCED SEMI BALANCED BALANCED CARTRIDGE BALANCED CARTRIDGE ELASTOMER METAL O-RING O-RING PUSHER DEAD END SINGLE O-RING PUSHER DOUBLE BELLOW BELLOW PUSHER STATIONARY DESIGN API PLAN23 (SINGLE-QUENCH) ● ○ ○ ○ BQ7EGG AQ1EM6G1 Q1BEGG BQ2EMG ○...
Page 20
e-IXP SERIES MECHANICAL SEALS SEAL OPERATING PRESSURE CALCULATION Seal operating pressure = Pump speed [rpm] Pump speed [rpm] Pump inlet pressure + ∆p [bar Size 2950 1450 Size 2950 1450 ∆p [bar] ∆p [bar] where, Pump inlet pressure is the pressure measured 40-25-160 125-80-200 on the suction flange (System pressure) and ∆p is the...
Page 21
IXPS SERIES MECHANICAL SEAL ARRANGEMENT - UNBALANCED - API PLAN 1 SEALING-DESIGN-CODE: S0 PUMP MATERIAL VERSION: DN, NN, RR Mechanical seal with main dimensions according to EN12756 and ISO3069 SEMIBALANCED O-RING PUSHER Frame Size [mm] [mm] [mm] 42,5 45,0 47,5 52,5 TENUTA MECCANICA POSITION 1 - 2...
Page 22
IXPS SERIES MECHANICAL SEAL ARRANGEMENT - SEMIBALANCED - API PLAN 1 SEALING-DESIGN-CODE: S0 PUMP MATERIAL VERSION: DN, NN, RR Mechanical seal with main dimensions according to EN12756 and ISO3069 SEMIBALANCED O-RING PUSHER STATIONARY EXECUTION Frame Size [mm] [mm] [mm] 42,5 45,0 47,5 52,5...
Page 23
IXP , IXPC, IXPF SERIES MECHANICAL SEAL ARRANGEMENT - UNBALANCED - API PLAN 1 SEALING-DESIGN-CODE: S1 PUMP MATERIAL VERSION: DN, NN, RN, RR (TT) Mechanical seal with main dimensions according to EN 12756 and ISO 3069 SEMIBALANCED O-RING PUSHER Frame Size [mm] [mm]...
Page 24
IXP , IXPC, IXPF SERIES MECHANICAL SEAL ARRANGEMENT - UNBALANCED - API PLAN 1 SEALING-DESIGN-CODE: S1 PUMP MATERIAL VERSION: DN, NN, RN, RR (TT) Unbalanced mechanical seal with main dimensions according to EN12756 and ISO3069 UNBALANCED O-RING PUSHER Frame Size [mm] [mm] [mm]...
Page 25
IXP , IXPC, IXPF SERIES MECHANICAL SEAL ARRANGEMENT - SEMIBALANCED - API PLAN 1 SEALING-DESIGN-CODE: S1 PUMP MATERIAL VERSION: DN, NN, RR Mechanical seal with main dimensions according to EN12756 and ISO3069 SEMIBALANCED O-RING PUSHER STATIONARY EXECUTION Frame Size [mm] [mm] [mm] 42,5...
Page 26
IXP , IXPC, IXPF SERIES MECHANICAL SEAL ARRANGEMENT - BALANCED - API PLAN 1 SEALING-DESIGN-CODE: S2 PUMP MATERIAL VERSION: DN, NN, RN, RR (TT) Mechanical seal with main dimensions according to EN12756 and ISO3069 BALANCED O-RING PUSHER Frame Size [mm] [mm] [mm] 50,0...
Page 27
IXP , IXPC, IXPF SERIES MECHANICAL SEAL ARRANGEMENT - UNBALANCED OR BALANCED with QUENCH SEALING-DESIGN-CODE: S4 or S5 PUMP MATERIAL VERSION: DN, NN, RN, RR, (TT) Mechanical seal arrengment (unbalanced or balanced version) with quench API-Plan61 (optional with API-Plan62) QUENCH "IN" QUENCH "OUT"...
Page 28
IXP , IXPC, IXPF SERIES MECHANICAL SEAL ARRANGEMENT - BALANCED “DEAD END” API PLAN 23T - “with thermosiphon cooling for hot Water” SEALING-DESIGN-CODE: T3 (water up to 180°C without external cooling water) PUMP MATERIAL VERSION: DN, NN, RN, RR Balanced mechanical seal with main dimensions according to EN12756 and ISO3069 BALANCED O-RING PUSHER...
Page 29
IXP , IXPC, IXPF SERIES MECHANICAL SEAL ARRANGEMENT - CARTRIDGE SEAL VERSIONS: SINGLE, SINGLE with QUENCH or DOUBLE SEALING-DESIGN-CODE: CS, CQ or CD PUMP MATERIAL VERSION: DN, NN, RN, RR, (TT) Drawing shows single cartridge seal as reference. Frame Size [mm] TENUTA MECCANICA ixp MATERIALI POSITION 1 - 2...
Page 30
e-IXP SERIES OPTIONAL CARTRIDGE MECHANICAL SEAL Installation dimensions for cartridge mechanical seals 25 a) 45° Ø d13 a) … Slot for additional piping - optional machining Maximum Frame Size Ød1 Ød11 Ød12 Ød13 Seal Outer Diameter [mm] [mm] [mm] [mm] [mm] [mm] [mm]...
Page 31
IXP , IXPC , IXPF SERIES STUFFING BOX ARRANGEMENT SEALING-DESIGN-CODE: P2 SOFT PACKING WITH INTERNAL SEALING LIQUID PUMP MATERIAL VERSION: DN, NN, RN Frame P [mm] Size [mm] [mm] [mm] [mm] 10(1+3) 10(1+3) 10(1+3) 12(1+3) MAX. SEAL TEMPERATURE SOFT PACKING DESCRIPTION OPERATING MAX.
Page 32
IXP , IXPC , IXPF SERIES STUFFING BOX ARRANGEMENT SEALING-DESIGN-CODE: P3 SOFT PACKING WITH EXTERNAL SEALING LIQUID PUMP MATERIAL VERSION: DN, NN, RN Frame P [mm] Size [mm] [mm] [mm] [mm] 10(1+3) 10(1+3) 10(1+3) 12,5(1+3) MAX. SEAL TEMPERATURE SOFT PACKING DESCRIPTION OPERATING MAX.
IXP , IXPC, IXPF BEARING FRAME - STANDARD VERSION GREASE LUBRICATION FIXED BEARING: DOUBLE ROW ANGULAR CONTACT BALL BEARING FLOATING BEARING: DEEP GROOVE BALL BEARING REGREASEABLE BY GREASE NIPPLE...
Page 34
IXP , IXPC, IXPF BEARING FRAME - OPTIONAL DESIGN GREASE LUBRICATION - SENSOR CONNECTIONS BEARING FRAME WITH CONNECTIONS FOR VIBRATION AND TEMPERATURE SENSORS VIBRATION SENSORS VS: FOR EACH BEARING HORIZONTAL AND VERTICAL TEMPERATURE SENSORS TS: ONE SENSOR PER BEARING Frame L (+/-2) Size [mm]...
Page 35
IXP , IXPC, IXPF BEARING FRAME - OPTIONAL DESIGN OIL LUBRICATION - SENSOR CONNECTIONS BEARING FRAME WITH OIL SUMP LUBRICATION STANDARD - OIL SIGHT GLASS / OPTIONAL - CONSTANT LEVEL OILER SHAFT SEALING: LABYRINTH SEALS STANDARD - CONNECTIONS FOR VIBRATION AND TEMPERATURE SENSORS...
e-IXP SERIES MOTORS (ErP 2009/125/EC) • • Short-circuit squirrel-cage motor, enclosed Rated power: construction with external ventilation (TEFC). from 1,5 to 200 kW 2 poles • from 1,1 to 110 kW 4 poles IP55 protection degree. from 1,1 to 30 kW 6 poles •...
Page 37
IXPF, IXPC SERIES THREE-PHASE MOTORS AT 50 Hz, 2 POLES (up to 18,5 kW) Manufacturer Xylem Service Italia Srl Data for 400 V / 50 Hz Voltage Reg. No. 07520560967 Montecchio Maggiore Vicenza - Italia N. of Poles ls / l...
Page 38
IXPF, IXPC SERIES THREE-PHASE MOTORS AT 50 Hz, 2 POLES (from 30 to 200 kW) Manufacturer OMEGA MOTOR SANAYI A.S. Data for 400 V / 50 Hz Voltage Dudullu Organize Sanayi Bölgesi 2. Cadde No: 10 34775 Ümraniye N. of ISTANBUL/TURKEY Reg.
Page 39
IXPS SERIES THREE-PHASE MOTORS AT 50 Hz, 2 POLES (up to 22 kW) Manufacturer Xylem Service Italia Srl Data for 400 V / 50 Hz Voltage Reg. No. 07520560967 Montecchio Maggiore Vicenza - Italia N. of Poles ls / l...
Page 40
IXPS SERIES THREE-PHASE MOTORS AT 50 Hz, 2 POLES (from 30 to 90 kW) Manufacturer OMEGA MOTOR SANAYI A.S. Data for 400 V / 50 Hz Voltage Dudullu Organize Sanayi Bölgesi 2. Cadde No: 10 34775 Ümraniye N. of ISTANBUL/TURKEY Reg. No. 913733 Poles ls / l Ts/T...
Page 41
MOTORI TRIFASE PER SERIE IXPF 50 Hz, 4 poli (fino a 15 kW) THREE-PHASE MOTORS AT 50 Hz, 4 POLES (from 1,1 to 15 kW) Manufacturer Data for 400 V / 50 Hz Voltage Xylem Service Italia Srl Reg. No. 07520560967 Montecchio Maggiore Vicenza - Italia N. of...
Page 42
IXPF, IXPC SERIES THREE-PHASE MOTORS AT 50 Hz, 4 POLES (from 18,5 to 110 kW) Manufacturer OMEGA MOTOR SANAYI A.S. Data for 400 V / 50 Hz Voltage Dudullu Organize Sanayi Bölgesi 2. Cadde No: 10 34775 Ümraniye N. of ISTANBUL/TURKEY Reg.
Page 43
IXPS SERIES THREE-PHASE MOTORS AT 50 Hz, 4 POLES (from 1,1 to 15 kW) Manufacturer Xylem Service Italia Srl Data for 400 V / 50 Hz Voltage Reg. No. 07520560967 Montecchio Maggiore Vicenza - Italia N. of Poles ls / l...
Page 44
IXPS SERIES THREE-PHASE MOTORS AT 50 Hz, 4 POLES (from 18,5 to 90 kW) Manufacturer OMEGA MOTOR SANAYI A.S. Data for 400 V / 50 Hz Voltage Dudullu Organize Sanayi Bölgesi 2. Cadde No: 10 34775 Ümraniye N. of ISTANBUL/TURKEY Reg. No. 913733 Poles Model ls / l...
Page 45
IXPF, IXPC SERIES THREE-PHASE MOTORS AT 50 Hz, 6 POLES Manufacturer WEG Equipementos Eletricos S.A. Data for 400 V / 50 Hz Voltage Reg. No. 07.175.725/0010-50 Jaragua do Sul - SC (Brazil) N. of Poles ls / l Ts/T Model cosj Tm/Tn W22 90L B3 1,1KW...
Page 46
e-IXP SERIES AVAILABLE VOLTAGES FOR PLM MOTORS THREE-PHASE 50/60 Hz 50 Hz 60 Hz 18,5 s = Standard voltage o = Voltage upon request - = Not available IXP-volt-lowa-en_a_te For higher power motors special voltages available on request. SOUND PRESSURE LEVELS The tables below show the mean sound pressure levels (Lp) measured at 1 meter distance in a free field according to EN ISO 11203.
2) The benchmark for most efficient water pumps is MEI ≥ 0,70. 3) Year of manufacture: see date on rating plate (≥ 2020). 4) Manufacturer: Xylem Service Italia Srl - Via dott. Vittorio Lombardi 14, 36075 Montecchio Maggiore (VI), Italia - Reg. No 07520560967.
e-IXP SERIES HYDRAULIC PERFORMANCE RANGE AT 50 Hz, 4 POLES e-IXP ~ 1450 [rpm] ISO 9906:2012 - Grade 2B Q [Imp gpm] 50 60 400 500 600 2000 3000 4000 Q [US gpm] 50 60 400 500 600 2000 3000 4000 5000 Q [m 50 60 400 500 600...
Page 82
e-IXP SERIES OPERATING CHARACTERISTICS AT 50 Hz, 4 POLES IXP 40-25-160 1400 [rpm] ISO 9906:2012 - Grade 2B Q [Imp gpm] Q [US gpm] h[%] 41.6 38.8 33.6 30.9 Ø173 Ø161 Ø147 Ø133 Ø173 Ø173 Ø161 Ø147 Ø133 Q [m Q [l/s] The NPSH values are the same from maximum to minimum impeller diameter.
Page 83
e-IXP SERIES OPERATING CHARACTERISTICS AT 50 Hz, 4 POLES IXP 40-25-200 1400 [rpm] ISO 9906:2012 - Grade 2B Q [Imp gpm] Q [US gpm] h[%] 43.8 41.6 38.6 Ø209 33.5 Ø193 Ø180 Ø165 Ø209 Ø209 Ø193 Ø180 Ø165 Q [m Q [l/s] The NPSH values are the same from maximum to minimum impeller diameter.
Page 84
e-IXP SERIES OPERATING CHARACTERISTICS AT 50 Hz, 4 POLES IXP 50-32-160 1400 [rpm] ISO 9906:2012 - Grade 2B Q [Imp gpm] Q [US gpm] h[%] 56.9 53.4 49.3 45.2 Ø171 Ø158 Ø144 Ø128 Ø171 Ø171 Ø158 Ø144 Ø128 Q [m Q [l/s] The NPSH values are the same from maximum to minimum impeller diameter.
Page 85
e-IXP SERIES OPERATING CHARACTERISTICS AT 50 Hz, 4 POLES IXP 50-32-200 1400 [rpm] ISO 9906:2012 - Grade 2B Q [Imp gpm] Q [US gpm] h[%] 50.9 47.7 42.9 40.3 Ø214 Ø198 Ø180 Ø166 Ø214 Ø214 Ø198 Ø180 Ø166 Q [m Q [l/s] The NPSH values are the same from maximum to minimum impeller diameter.
Page 86
e-IXP SERIES OPERATING CHARACTERISTICS AT 50 Hz, 4 POLES IXP 50-32-250 1450 [rpm] ISO 9906:2012 - Grade 2B Q [Imp gpm] Q [US gpm] h[%] 45.8 41.8 Ø259 38.8 Ø234 Ø209 Ø259 Ø259 Ø234 Ø209 Ø209 Q [m Q [l/s] The NPSH values are the same from maximum to minimum impeller diameter.
Page 87
e-IXP SERIES OPERATING CHARACTERISTICS AT 50 Hz, 4 POLES IXP 65-50-160 1400 [rpm] ISO 9906:2012 - Grade 2B Q [Imp gpm] Q [US gpm] 65.5 h[%] 62.9 60.5 57.8 Ø173 Ø161 Ø149 Ø137 Ø173 Ø173 Ø161 Ø149 Ø137 Q [m Q [l/s] The NPSH values are the same from maximum to minimum impeller diameter.
Page 88
e-IXP SERIES OPERATING CHARACTERISTICS AT 50 Hz, 4 POLES IXP 65-40-200 1450 [rpm] ISO 9906:2012 - Grade 2B Q [Imp gpm] Q [US gpm] h[%] 64.3 64.0 62.6 59.7 Ø212 Ø208 Ø188 Ø168 Ø212 Ø212 Ø208 Ø188 Ø168 Q [m Q [l/s] The NPSH values are the same from maximum to minimum impeller diameter.
Page 89
e-IXP SERIES OPERATING CHARACTERISTICS AT 50 Hz, 4 POLES IXP 65-40-250 1450 [rpm] ISO 9906:2012 - Grade 2B Q [Imp gpm] Q [US gpm] h[%] 55.4 52.3 45.1 45.1 Ø257 Ø237 Ø205 Ø205 Ø257 Ø257 Ø237 Ø205 Ø205 Q [m Q [l/s] The NPSH values are laboratory values;...
Page 90
e-IXP SERIES OPERATING CHARACTERISTICS AT 50 Hz, 4 POLES IXP 65-40-315 1450 [rpm] ISO 9906:2012 - Grade 2B Q [Imp gpm] Q [US gpm] h[%] 46.1 43.4 40.3 40.3 Ø319 Ø289 Ø263 Ø319 Ø319 Ø289 Ø263 Ø263 Q [m Q [l/s] The NPSH values are the same from maximum to minimum impeller diameter.
Page 91
e-IXP SERIES OPERATING CHARACTERISTICS AT 50 Hz, 4 POLES IXP 80-65-125 1400 [rpm] ISO 9906:2012 - Grade 2B Q [Imp gpm] Q [US gpm] h[%] 73.9 67.3 60.3 Ø150 Ø132 Ø114 Ø150 Ø150 Ø132 Ø114 Q [m Q [l/s] The NPSH values are the same from maximum to minimum impeller diameter. The NPSH values are laboratory values;...
Page 92
e-IXP SERIES OPERATING CHARACTERISTICS AT 50 Hz, 4 POLES IXP 80-65-160 1450 [rpm] ISO 9906:2012 - Grade 2B Q [Imp gpm] Q [US gpm] h[%] 75.1 73.2 71.9 69.0 Ø173 Ø161 Ø149 Ø137 Ø173 Ø173 Ø161 Ø149 Ø137 Q [m Q [l/s] The NPSH values are the same from maximum to minimum impeller diameter.
Page 93
e-IXP SERIES OPERATING CHARACTERISTICS AT 50 Hz, 4 POLES IXP 80-50-200 1450 [rpm] ISO 9906:2012 - Grade 2B Q [Imp gpm] Q [US gpm] h[%] 70.8 68.6 65.8 62.7 Ø210 Ø194 Ø178 Ø166 Ø166 Ø210 Ø210 Ø194 Ø178 Ø166 Q [m Q [l/s] The NPSH values are the same from maximum to minimum impeller diameter.
Page 94
e-IXP SERIES OPERATING CHARACTERISTICS AT 50 Hz, 4 POLES IXP 80-50-250 1450 [rpm] ISO 9906:2012 - Grade 2B Q [Imp gpm] Q [US gpm] h[%] 66.6 64.9 62.6 62.6 Ø259 Ø229 Ø204 Ø204 Ø204 Ø204 Ø259 Ø259 Ø229 Ø204 Ø204 Q [m Q [l/s] The NPSH values are laboratory values;...
Page 95
e-IXP SERIES OPERATING CHARACTERISTICS AT 50 Hz, 4 POLES IXP 80-50-315 1450 [rpm] ISO 9906:2012 - Grade 2B Q [Imp gpm] Q [US gpm] h[%] 67.5 66.3 62.9 Ø322 Ø310 53.9 Ø285 Ø256 Ø322 Ø322 Ø310 Ø285 Ø256 Q [m Q [l/s] The NPSH values are the same from maximum to minimum impeller diameter.
Page 96
e-IXP SERIES OPERATING CHARACTERISTICS AT 50 Hz, 4 POLES IXP 100-80-125 1400 [rpm] ISO 9906:2012 - Grade 2B Q [Imp gpm] Q [US gpm] h[%] 78.6 73.6 69.7 64.6 Ø148 Ø135 Ø127 Ø115 Ø148 Ø148 Ø135 Ø127 Ø115 Q [m Q [l/s] The NPSH values are the same from maximum to minimum impeller diameter.
Page 97
e-IXP SERIES OPERATING CHARACTERISTICS AT 50 Hz, 4 POLES IXP 100-80-160 1450 [rpm] ISO 9906:2012 - Grade 2B Q [Imp gpm] Q [US gpm] h[%] 77.2 76.4 70.2 Ø180 Ø164 Ø144 Ø180 Ø180 Ø164 Ø144 Q [m Q [l/s] The NPSH values are the same from maximum to minimum impeller diameter. The NPSH values are laboratory values;...
Page 98
e-IXP SERIES OPERATING CHARACTERISTICS AT 50 Hz, 4 POLES IXP 100-65-200 1450 [rpm] ISO 9906:2012 - Grade 2B Q [Imp gpm] Q [US gpm] h[%] 76.7 74.2 72.3 69.1 Ø220 Ø206 Ø190 Ø176 Ø220 Ø220 Ø206 Ø190 Ø176 Q [m Q [l/s] The NPSH values are the same from maximum to minimum impeller diameter.
Page 99
e-IXP SERIES OPERATING CHARACTERISTICS AT 50 Hz, 4 POLES IXP 100-65-250 1475 [rpm] ISO 9906:2012 - Grade 2B Q [Imp gpm] Q [US gpm] h[%] 75.2 74.3 70.9 Ø259 Ø243 Ø219 Ø259 Ø259 Ø243 Ø219 Ø219 Q [m Q [l/s] The NPSH values are the same from maximum to minimum impeller diameter.
Page 100
e-IXP SERIES OPERATING CHARACTERISTICS AT 50 Hz, 4 POLES IXP 100-65-315 1475 [rpm] ISO 9906:2012 - Grade 2B Q [Imp gpm] Q [US gpm] h[%] 69.2 69.0 67.4 63.4 Ø327 Ø315 Ø283 Ø255 Ø255 Ø327 Ø327 Ø315 Ø283 Ø255 Q [m Q [l/s] The NPSH values are laboratory values;...
Page 101
e-IXP SERIES OPERATING CHARACTERISTICS AT 50 Hz, 4 POLES IXP 125-80-160 1450 [rpm] ISO 9906:2012 - Grade 2B Q [Imp gpm] Q [US gpm] h[%] 77.1 70.6 66.7 Ø177 62.0 Ø161 Ø145 Ø133 Ø177 Ø177 Ø161 Ø145 Ø133 Q [m Q [l/s] The NPSH values are the same from maximum to minimum impeller diameter.
Page 102
e-IXP SERIES OPERATING CHARACTERISTICS AT 50 Hz, 4 POLES IXP 125-80-200 1475 [rpm] ISO 9906:2012 - Grade 2B Q [Imp gpm] Q [US gpm] h[%] 82.8 82.0 79.1 Ø220 77.6 Ø208 Ø192 Ø176 Ø220 Ø220 Ø208 Ø192 Ø176 Q [m Q [l/s] The NPSH values are the same from maximum to minimum impeller diameter.
Page 103
e-IXP SERIES OPERATING CHARACTERISTICS AT 50 Hz, 4 POLES IXP 125-80-250 1475 [rpm] ISO 9906:2012 - Grade 2B Q [Imp gpm] Q [US gpm] h[%] 82.2 81.1 79.6 79.2 Ø259 Ø247 Ø223 Ø214 Ø259 Ø259 Ø247 Ø223 Ø214 Q [m Q [l/s] The NPSH values are the same from maximum to minimum impeller diameter.
e-IXP SERIES HYDRAULIC PERFORMANCE RANGE AT 50 Hz, 6 POLES e-IXP ~ 950 [rpm] ISO 9906:2012 - Grade 2B Q [Imp gpm] Q [US gpm] Q [m Q [l/s]...
Page 123
e-IXP SERIES OPERATING CHARACTERISTICS AT 50 Hz, 6 POLES IXP 125-100-160 950 [rpm] ISO 9906:2012 - Grade 2B Q [Imp gpm] Q [US gpm] h[%] 80.7 78.0 75.5 Ø190 Ø176 Ø155 Ø190 Ø190 Ø176 Ø155 Q [m Q [l/s] The NPSH values are the same from maximum to minimum impeller diameter. The NPSH values are laboratory values;...
Page 124
e-IXP SERIES OPERATING CHARACTERISTICS AT 50 Hz, 6 POLES IXP 125-100-200 950 [rpm] ISO 9906:2012 - Grade 2B Q [Imp gpm] Q [US gpm] h[%] 82.1 81.1 79.1 79.1 Ø229 Ø208 Ø188 Ø229 Ø188 Ø229 Ø208 Ø188 Ø188 Q [m Q [l/s] The NPSH values are laboratory values;...
Page 125
e-IXP SERIES OPERATING CHARACTERISTICS AT 50 Hz, 6 POLES IXP 150-125-200 960 [rpm] ISO 9906:2012 - Grade 2B Q [Imp gpm] 1000 Q [US gpm] h[%] 84.1 82.5 79.8 Ø225 Ø204 Ø179 Ø225 Ø225 Ø204 Ø179 Ø179 Q [m Q [l/s] The NPSH values are the same from maximum to minimum impeller diameter.
Page 126
e-IXP SERIES OPERATING CHARACTERISTICS AT 50 Hz, 6 POLES IXP 150-125-250 960 [rpm] ISO 9906:2012 - Grade 2B Q [Imp gpm] 1000 Q [US gpm] h[%] 85.4 84.6 83.1 Ø259 Ø249 Ø210 Ø259 Ø210 Ø259 Ø249 Ø210 Q [m Q [l/s] The NPSH values are laboratory values;...
Page 127
e-IXP SERIES OPERATING CHARACTERISTICS AT 50 Hz, 6 POLES IXP 150-125-315 975 [rpm] ISO 9906:2012 - Grade 2B 1000 Q [Imp gpm] 1000 1200 Q [US gpm] h[%] 84.7 83.0 82.4 82.4 Ø334 Ø302 Ø277 Ø334 Ø334 Ø302 Ø277 Ø277 Q [m Q [l/s] The NPSH values are the same from maximum to minimum impeller diameter.
Page 128
e-IXP SERIES OPERATING CHARACTERISTICS AT 50 Hz, 6 POLES IXP 150-125-400 975 [rpm] ISO 9906:2012 - Grade 2B 1000 Q [Imp gpm] 1000 1200 Q [US gpm] 80.7 h[%] 79.1 77.7 77.7 Ø418 Ø388 Ø353 Ø418 Ø418 Ø388 Ø353 Ø353 Q [m Q [l/s] The NPSH values are the same from maximum to minimum impeller diameter.
Page 138
e-IXP SERIES (BARE SHAFT) DIMENSIONS AND WEIGHTS AT 50 Hz Shaft end B max. Connections: D: Drain G ½” PM1: Pressure gauge connector G ¼” (discharge side) V1: Pressure gauge connector G ¼” (suction side) IXP-BS-EN_A_DD...
Page 139
e-IXP SERIES (BARE SHAFT) DIMENSIONS AND WEIGHTS AT 50 Hz DIMENSIONS (mm) PUMP TYPE PUMP SHAFT BARE SHAFT DNS DND a h2 m1 m2 n1 w ØCA d u max x 40-25-160 50 385 13 132 160 100 70 240 190 110 160 37 22 M12 M12 285 165 24 273 100 40-25-200...
Page 140
IXPC SERIES DIMENSIONS AND WEIGHTS AT 50 Hz, 2 POLES z x Øs Connections: D: Drain G ½” PM1: Pressure gauge connector G ¼” (discharge side) V1: Pressure gauge connector G ¼” (suction side) IXPC-AS-EN_A_DD...
Page 141
IXPC SERIES DIMENSIONS AND WEIGHTS AT 50 Hz, 2 POLES DIMENSIONS [mm] PUMP TYPE z x s IXPC Size [kW] DNS DND max. FOR SCREWS [kg] 40-25-160 60 360 320 385 225 160 913 850 150 275 100 385 6xØ19 (M16) H80A 40-25-160 60 360 320 385 225 160 913...
Page 142
IXPC SERIES DIMENSIONS AND WEIGHTS AT 50 Hz, 2 POLES PUMP TYPE DIMENSIONS [mm] z x s IXPC Size [kW] DNS DND max. FOR SCREWS [kg] 80-65-125 100L 65 100 60 360 320 385 225 160 964 850 150 275 100 385 6xØ19 (M16) H80B 80-65-125...
Page 143
IXPC SERIES DIMENSIONS AND WEIGHTS AT 50 Hz, 2 POLES DIMENSIONS [mm] PUMP TYPE z x s IXPC Size [kW] DNS DND max. FOR SCREWS [kg] 100-80-125 132S 5,5 100 80 100 75 400 360 385 253 180 1032 1000 150 350 100 444 6xØ19 (M16) H95A 100-80-125...
Page 144
IXPC SERIES DIMENSIONS AND WEIGHTS AT 50 Hz, 2 POLES DIMENSIONS [mm] PUMP TYPE z x s IXPC Size [kW] DNS DND max. FOR SCREWS [kg] 125-100-160 160M 15 125 100 125 90 500 460 500 318 280 1369 1250 180 445 140 598 6xØ19 (M16) H95K 125-100-160...
Page 145
IXPC SERIES DIMENSIONS AND WEIGHTS AT 50 Hz, 4 POLES z x Øs Connections: D: Drain G ½” PM1: Pressure gauge connector G ¼” (discharge side) V1: Pressure gauge connector G ¼” (suction side) IXPC-AS-EN_A_DD...
Page 146
IXPC SERIES DIMENSIONS AND WEIGHTS AT 50 Hz, 4 POLES DIMENSIONS [mm] PUMP TYPE z x s IXPC Size [kW] DNS DND max. FOR SCREWS [kg] 40-25-160 60 360 320 385 225 160 913 850 150 275 100 385 6xØ19(M16) H80A 40-25-200 60 360 320 385 253 180 913...
Page 147
IXPC SERIES DIMENSIONS AND WEIGHTS AT 50 Hz, 4 POLES PUMP TYPE DIMENSIONS [mm] z x s IXPC Size [kW] DNS DND max. FOR SCREWS [kg] 100-80-125 1,1 100 80 100 75 400 360 385 253 180 933 850 150 275 100 433 6xØ19(M16) H80A 100-80-125...
Page 148
IXPC SERIES DIMENSIONS AND WEIGHTS AT 50 Hz, 4 POLES DIMENSIONS [mm] PUMP TYPE IXPC z x s Size [kW] DNS DND max. FOR SCREWS [kg] 125-100-160 100L 2,2 125 100 125 90 500 460 500 298 280 1207 1050 150 375 140 578 6xØ19(M16) H95H 125-100-160...
Page 149
IXPC SERIES DIMENSIONS AND WEIGHTS XIPC AT 50 Hz, 4 POLES DIMENSIONS AND WEIGHTS AT 50 Hz, 4 POLES DIMENSIONS [mm] PUMP TYPE z x s IXPC Size [kW] DNS DND max. FOR SCREWS [kg] 200-150-200 160M 200 150 160 110 680 640 530 403 400 1474 1350 180 495 180 803 6xØ19(M16) H110F 200-150-200...
Page 150
IXPC SERIES DIMENSIONS AND WEIGHTS AT 50 Hz, 6 POLES z x Øs Connections: D: Drain G ½” PM1: Pressure gauge connector G ¼” (discharge side) V1: Pressure gauge connector G ¼” (suction side) IXPC-AS-EN_A_DD...
Page 151
IXPC SERIES DIMENSIONS AND WEIGHTS AT 50 Hz, 6 POLES DIMENSIONS AND WEIGHTS XIPC AT 50 Hz, 6 POLES DIMENSIONS [mm] PUMP TYPE IXPC z x s Size [kW] DNS DND max. FOR SCREWS [kg] 125-100-160 1,1 125 100 125 90 500 460 500 298 280 1125 1000 150 350 140 6 x Ø19 (M16) H95G 125-100-200...
Page 152
IXPS SERIES DIMENSIONS AND WEIGHTS AT 50 Hz B max. B max. Connections: D: Drain G ½” PM1: Pressure gauge connector G ¼” (discharge side) V1: Pressure gauge connector G ¼” (suction side) IXPS1-EN_A_DD...
Page 153
IXPS SERIES DIMENSIONS AND WEIGHTS AT 50 Hz B max. B max. Connections: D: Drain G ½” PM1: Pressure gauge connector G ¼” (discharge side) V1: Pressure gauge connector G ¼” (suction side) IXPS2-EN_A_DD...
Page 154
IXPS SERIES DIMENSIONS AND WEIGHTS AT 50 Hz, 2 POLES DIMENSIONS [mm] PUMP TYPE PUMP IXPS DNS DND Size [kW] 40-25-160 40-25-160 40-25-160 100L 40-25-160 112M 40-25-200 100L 40-25-200 112M 40-25-200 40-25-200 132S 50-32-160 100L 50-32-160 112M 50-32-160 50-32-160 132S 50-32-200 112M 50-32-200...
Page 155
IXPS SERIES DIMENSIONS AND WEIGHTS AT 50 Hz, 2 POLES DIMENSIONS [mm] PUMP TYPE MOTOR IXPS Size [kW] max. max. [kg] 40-25-160 40-25-160 40-25-160 100L 40-25-160 112M 40-25-200 100L 40-25-200 112M 40-25-200 40-25-200 132S 50-32-160 100L 50-32-160 112M 50-32-160 50-32-160 132S 50-32-200 112M...
Page 156
IXPS SERIES DIMENSIONS AND WEIGHTS AT 50 Hz, 2 POLES DIMENSIONS [mm] PUMP TYPE PUMP IXPS DNS DND Size [kW] 100-80-125 100-80-125 132S 100-80-125 160M 100-80-125 160M 100-80-160 132S 100-80-160 160M 100-80-160 160M 100-80-160 160L 18,5 100-80-160 180R 100-65-200 160M 100-65-200 160M 100-65-200...
Page 157
IXPS SERIES DIMENSIONS AND WEIGHTS AT 50 Hz, 2 POLES DIMENSIONS [mm] PUMP TYPE MOTOR IXPS Size [kW] max. max. [kg] 100-80-125 100-80-125 132S 100-80-125 160M 100-80-125 160M 100-80-160 132S 100-80-160 160M 100-80-160 160M 100-80-160 160L 18,5 100-80-160 180R 100-65-200 160M 100-65-200 160M...
Page 158
IXPS SERIES DIMENSIONS AND WEIGHTS AT 50 Hz, 4 POLES PUMP TYPE DIMENSIONS [mm] IXPS Size [kW] 40-25-160 40-25-200 50-32-160 50-32-200 50-32-250 50-32-250 50-32-250 100L 65-50-160 65-40-200 65-40-200 65-40-250 65-40-250 100L 65-40-250 100L 65-40-315 112M 65-40-315 132M 80-65-125 80-65-160 80-65-160 80-50-200 80-50-200 100L...
Page 159
IXPS SERIES DIMENSIONS AND WEIGHTS AT 50 Hz, 4 POLES DIMENSIONS [mm] PUMP TYPE MOTOR IXPS Size [kW] max. max. [kg] 40-25-160 40-25-200 50-32-160 50-32-200 50-32-250 50-32-250 50-32-250 100L 65-50-160 65-40-200 65-40-200 65-40-250 65-40-250 100L 65-40-250 100L 65-40-315 112M 65-40-315 132M 80-65-125 80-65-160...
Page 160
IXPS SERIES DIMENSIONS AND WEIGHTS AT 50 Hz, 4 POLES PUMP TYPE DIMENSIONS [mm] IXPS Size [kW] 125-100-160 100L 125-100-160 100L 125-100-160 112M 125-100-200 112M 125-100-200 132M 125-100-200 132M 125-100-200 160M 125-100-250 132M 125-100-250 132M 125-100-250 160M 125-100-250 160L 125-100-315 160M 125-100-315 160L 125-100-315 180M 18,5 125-100-315 180L...
Page 161
IXPS SERIES DIMENSIONS AND WEIGHTS AT 50 Hz, 4 POLES DIMENSIONS [mm] PUMP TYPE MOTOR IXPS Size [kW] max. max. [kg] 125-100-160 100L 125-100-160 100L 125-100-160 112M 125-100-200 112M 125-100-200 132M 125-100-200 132M 125-100-200 160M 125-100-250 132M 125-100-250 132M 125-100-250 160M 125-100-250 160L 125-100-315 160M 125-100-315 160L...
IXPC , IXPF PUMP BASE FRAME STANDARD DESIGN FOR IXPC, IXPF PUMPS BASE FRAME MUST BE FILLED WITH CONCRETE STANDARD MATERIAL : CARBON STEEL (PAINTED), ALL SCREWS: V2A OPTIONAL DESIGN : WITH DRIP PAN (316SS) OPTIONAL MATERIAL : CARBON STEEL ZINC PLATED STANDARD ANCHOR BOLT CHEMICAL ANCHOR BOLT (DIN 529)
IXP , IXPF, IXPC SERIES PERMISSIBLE FORCES AND MOMENTS AT PUMP NOZZLES Forces at the pump flanges calculated according to EN ISO 5199:2002. When the applied loads do not all attain the maximun values allowed, one of these loads may exceed the normal limit, provided tha the following supplementary conditions are satisfied:...
Page 166
IXPS SERIES PERMISSIBLE FORCES AND MOMENTS AT PUMP NOZZLES Forces at the pump flanges calculated according to EN ISO 5199:2002. When the applied loads do not all attain the maximun values allowed, one of these loads may exceed the normal limit, provided tha the following supplementary conditions are satisfied: - any component of a force or of a moment shall be...
OPTIMYZE ™ CONDITION MONITORING TO OPTIMIZE YOUR BOTTOM LINE The optimyze™ modular condition monitoring solution provides health guidance and predictive maintenance advice for rotating and fixed assets such as pumps, motors, heat exchangers and steam traps. It periodically monitors system vibration and temperature and allows everyday users to access simple-to-use monitoring tools from iOS or Android mobile devices.
Page 168
OPTIMYZE™ CONDITION MONITORING AND OPTIMIZATION SPECIFICATIONS Surface Temperature Measurement Measurement range -20°C to +135°C (-4°F to +275°F) Measurement method Non-contact infrared laser Minor gradient accuracy (0°C to 25°C gradient) +/- 1°C Moderate gradient accuracy (25°C to 50°C gradient) +/- 2°C Large gradient accuracy (50°C to 100°C gradient) +/- 4°C Vibration Measurement...
IXP ..H SERIES e-IXP WITH HYDROVAR Background and context Identification code: For all pumping needs the demand for intelligent pumping IXP..H models are identified by the letter “H”. systems is constantly growing. Controlled systems offer Key Features of the HYDROVAR many advantages: reduced operating costs for the lifetime of the pump, lower environmental impact, longer lifetime of piping systems and networks.
Page 171
Lowara IXP ..H SERIES e-IXP WITH HYDROVAR OPERATING PRINCIPLE The basic function of the HYDROVAR device is to control the pump to meet the system demands. The basic function of the HYDROVAR device is to ® control the pump to meet the system demands. HYDROVAR performs these functions by: HYDROVAR performs these functions by:...
1,9% 29,4 0,0% 0,5% 0,7% 1,3% 0,6% 0,9% 1,6% 1,0% 2,1% hvl-pl-en_a_te Operating conditions* Manufacturer Xylem Service Italia Srl Altitude T.amb Reg. No. 07520560967 min/max ATEX Montecchio Maggiore (VI) - Italia nout Nout Model °C HVL 2.015-.. 11,6 HVL 2.022-..
Page 173
HYDROVAR HVL IDENTIFICATION CODE H V L Other options [1 digit] [0] = reserved for future use Rated output power [3 digits] Display [1 digit] kW x 10 [0] = reserved for future use [1] = Internal display installed as standard Power supply [2 digits] [2.] = 1~ 208-240 V (50/60 Hz) Optional cards [1 digit]...
Page 174
C1 (*) 3.015 ÷ 3.110 C2 (*) 4.015 ÷ 4.220 C2 (*) (*) 0,75 motor cable length; contact Xylem for further information En-Rev_A CARD Premium Card HYDROVAR For the IXP..H the Premium Card comes fitted as standard on the standalone HYDROVAR.
Page 175
HYDROVAR HVL (WALL MOUNTING KIT) DIMENSIONS AND WEIGHTS As an option a HYDROVAR wall mounting kit is also available, this is used where mounting on the pump unit is impossible or where you would like the controls in another location, these are available for the new generation HYDROVAR HVL 2.015-4.220 (22 kW).
Page 180
REPORTS AND DECLARATIONS i) Test reports a) Factory Test Report - Test report compiled at the end of the assembly line, including flow-head performance test (ISO 9906:2012 – Grade 2B) and hydrostatic pressure test. b) Audit Test Report - Test report for electric pumps compiled in the test room, comprising flow-head-pump input-pump efficiency performance test (according to ISO 9906:2012) c) NPSH Test Report - Test report for electric pumps compiled in the test room, comprising flow-NPSH performance test...
Page 182
NPSH The minimum operating values that can be reached at the The maximum possible suction head for installation pump suction end are limited by the onset of cavitation. depends on the value of the atmospheric pressure (i.e. the elevation above sea level at which the pump Cavitation is the formation of vapour-filled cavities within is installed) and the temperature of the liquid.
Page 183
TENSIONE DI VAPORE VAPOUR PRESSURE TABELLA TENSIONE DI VAPORE ps E DENSITA' ρ DELL'ACQUA VAPOUR PRESSURE ps AND ρ DENSITY OF WATER TABLE ρ ρ ρ °C °C °C kg/dm kg/dm kg/dm 273,15 0,00611 0,9998 328,15 0,15741 0,9857 393,15 1,9854 0,9429 274,15 0,00657...
Page 184
TABLE OF FLOW RESISTANCE IN 100 m OF STRAIGHT CAST IRON PIPELINE (HAZEN-WILLIAMS FORMULA C=100) FLOW RATE NOMINAL DIAMETER in mm and inches l/min 1/2" 3/4" 1" 1 1/4" 1 1/2" 2 1/2" 3" 4" 5" 6" 7" 8" 10" 12"...
Page 185
FLOW RESISTANCE TABLE OF FLOW RESISTANCE IN BENDS, VALVES AND GATES The flow resistance is calculated using the equivalent pipeline length method according to the table below: TABELLA LUNGHEZZA DI TUBAZIONE EQUIVALENTE ACCESSORY TYPE Equivalent pipeline length (m) 45° bend 90°...
Page 186
VOLUMETRIC CAPACITY Litres Cubic metres Cubic feet Cubic feet Imperial gallon U.S. gallon per minute per hour per hour per minute per minute per minute l/min Imp. gal/min US gal/min /min 1,0000 0,0600 2,1189 0,0353 0,2200 0,2642 1,0000 16,6667 35,3147 0,5886 3,6662 4,4029...
Page 187
FURTHER PRODUCT SELECTION AND DOCUMENTATION Xylect Xylect is pump solution selection software with an extensive online database of product information across the entire Lowara range of pumps and related products, with multiple search options and helpful project management facilities. The system holds up-to-date product information on thousands of products and accessories. The possibility to search by applications and the detailed information output given makes it easy to make the optimal selection without having detailed knowledge about the Lowara products.
Page 188
FURTHER PRODUCT SELECTION AND DOCUMENTATION Xylect The detailed output makes it easy to select the optimal pump from the given alternatives. The best way to work with Xylect is to create a personal account. This makes it possible to: • Set own standard units •...
Page 190
Our products and services move, treat, analyze, monitor and return water to the environment, in public utility, industrial, residential and commercial building services settings. Xylem also provides a leading portfolio of smart metering, network technologies and advanced analytics solutions for water, electric and gas utilities.
Need help?
Do you have a question about the LOWARA e-IXP Series and is the answer not in the manual?
Questions and answers