Ground Power Universal Unit 3000 Peak Starting Amps: 50 Amps Continuous @
28.5 Vdc DC NATO Cable Assembly 15ft. AC Line Cord 120 VAC 10ft. AC Line
Cord 240 10ft.
FOB: Destination
MFR PART NR: TI3000 GPU-24UNV
PSC CD: 6150
Quantity: 6
Please let me know if you have any questions
Please give us the best discounted price, including shipping charges
Thank You
Hazel Grey
Procurement Manager
BEST SERVICE PROS, LLC
Purchasing Department
procurement@bestservicepros.us
+1 (929) 487 1019
251-21 JERICHO TURNPIKE,
JAMAICA, NY, 11426, USA
bestservicepros.us
Page 1
Power Anytime, Anywhere Tesla TI3000 GPU-24-UNV ™ User Manual Built Smart...Proven Tough Tesla Industries, Inc. 101 Centerpoint Blvd. New Castle, DE 19720 (302) 324-8910 Phone (302) 324-8912 Fax www.teslaind.com www.tesla1.com...
Page 2
Any attempts to open or examine the inside of the TI3000 GPU-24-UNV via a tool or device (borescope, probe, etc.) can result in unit failure and/or injury by electrical shock. This GPU is mainte nance free and should not be opened or disassembled for any reason.
Page 3
Chemical Family/Classification: Tesla™ Industries, Inc. Sealed Lead Battery Synonyms: Telephone: Sealed Lead Acid Battery, VRLA Battery For information, contact Tesla™ Industries, Inc. Manufacturer's Name/Address: Customer Service Department at 302-324-8910 Tesla™ Industries, Inc 101 Centerpoint Blvd. 24-Hour Emergency Response Contact: New Castle, DE 19720-4180...
Page 4
Supersedes: AF ECO #: 1002195 Inorganic lead and sulfuric acid electrolyte are the primary components of every battery manufactured by Tesla™ Products. There are no mercury or cadmium containing products present in batteries manufactured by Tesla™ Products. IV. FIRST AID MEASURES Inhalation: Sulfuric Acid: Remove to fresh air immediately.
3.6 – Temperature Specifications 3.7 – Environmental 3.8 – Normal Functional Test Procedures 13-14 3.9 – Pre-Operation 3.10 – Transporting Unit 3.11 – Regulated 28.5 VDC Ground Power 16-17 3.12 – Regulated AC Power 3.13 – Charging Unit TI3000 GPU-24-UNV...
Page 6
7.7 – Output Voltage 7.8 – Maximum Output Current Section 8 – Optional Accessories 8.1 – Shipping Case 8.2 – GPU Protective Covers 8.3 – Cobra™ DC Replacement Contacts and Tools 8.4 – GPU Tires Repair Request Form TI3000 GPU-24-UNV...
Page 7
Maximum MΩ megaohm Minimum Micro Power Unit NEMA National Electrical Manufacturers Association Ω power factor power factor correction root-mean-square Total Harmonic Distortion TMDE Test, Measurement, & Diagnostic Equipment Unmanned aerial vehicle Volts, Alternating Current Volts, Direct Current watts TI3000 GPU-24-UNV...
The following symbols will appear within the warning triangles to alert the user to the specifi c type of danger or hazard. General Warning Electrical Hazard Explosion Hazard Fire Hazard Battery Warning Guard from Moisture Figure 1.2.1 – Different types of hazard and caution symbols TI3000 GPU-24-UNV...
150°F (65°C). This protects the unit from overheating and damage. If the unit shuts down, move the unit into a cooler environment such as shade or air conditioning when possible. Perform a full function test, after the unit has been allowed to cool, prior to use. TI3000 GPU-24-UNV...
Section 2 – Product Overview 2.1 – Introduction Thank you and congratulations on the purchase of your new TI3000 GPU-24-UNV Ground Power Unit. The TI3000 GPU-24-UNV provides dc electrical ground power for aircraft flight line, maintenance, and ground support operations. The unit is designed to provide 24 volt dc electrical power output for aircraft engine starting and 24 or 28.5 volts dc electrical support for ground maintenance, avionics/electrical troubleshooting...
Phase 100-260 Vac line voltage. Air Intake Ports – Provide airflow for cooling Input Connector Protective Cap – Protects ac input internal electronics. from dust and foreign materials when not in use. Telescopic Handle – Allows for easy transport of unit. TI3000 GPU-24-UNV...
CAUTION Ensure that ports are clear at all times. When the TI3000 GPU-24-UNV is plugged into Single Phase 100-260, Vac 50/60 Hz ac power, the internal cooling system will efficiently regulate unit temperature regardless of load. At room temperature (+77°F) the exhaust air will not exceed the ambient temperature by more than 5°F.
Product Overview 2.7 – Operating Positions The TI3000 GPU-24-UNV can be operated in both the horizontal (Figure 2.7.1) and vertical (Figure 2.7.2) positions as shown. Make sure that the airflow is not obstructed from air intake (figure 2.7.3) and outlet (Figure 2.7.4).
Reset breaker by pressing red button. Reconnect ac and dc connections to the unit. (Plug in ac line cord on military unit.) The unit should power up automatically. If the breaker continues to trip, return the unit to Tesla™ Industries for repair.
“Push to Test” function. (If this sensor is tripped, allow ten minutes for unit to cool before operating “Push to Test” button.) Figure 2.10.1 - “Push to Test” button location STATUS STATUS STATUS Full Charge Half Charge No Charge TI3000 GPU-24-UNV...
If the unit shuts down, move the unit into a cooler climate, such as shade or air conditioning when possible. Perform a full function test prior to use after the unit has been allowed to cool. TI3000 GPU-24-UNV...
A. Prevent accumulation of moisture on ac and dc connectors/receptacles B. Minimize moisture entering forward inlet and outlet cooling fan vent ports When not in use, unit inlet and outlet vent ports shall be covered from exposure. Unit shall be kept horizontal. TI3000 GPU-24-UNV...
Check for dents, punctures, case distortion or misalignment, and cracked or loose connec tors. If no damage is evident, proceed to the next step. If damage is evident, contact Tesla™ Industries, Inc. Check DC Voltage Reading at DC Receptacle Terminals Figure 3.8.1 –...
Page 21
Move the negative receptacle. Move the positive probe to the DC negative post. probe to the DC positive post. Multimeter should read 0 Volts. Multimeter should read 0 Volts. TI3000 GPU-24-UNV...
Figure 3.9.1 - TI3000 GPU-24-UNV 3.10 – Transporting Unit The TI3000 GPU-24-UNV has a telescoping handle that makes rolling the unit easy. For transporting on uneven ground, axle extensions should be added to the unit. For use on sand, balloon tires should be installed on the unit (see Optional Accessories).
(26.5 Vdc minimum). If aircraft power demand is less than 50 amps converter output will remain at 28.5 Vdc (only one GREEN LED status indicator bar will illuminate). If aircraft power demand exceeds 50 amps converter voltage output will decrease and two or more LED status indicator bars will illuminate. TI3000 GPU-24-UNV...
Page 24
Figure 3.11.4 Starting UH-1 Huey Helicopter with TI3000 GPU-24-UNV Removing DC Power Supply From Vehicle Remove dc power cable GPU connector from vehicle. Remove dc power cable connector from TI3000 GPU-24-UNV (if necessary). Reinstall dc receptacle’s protective cover. TI3000 GPU-24-UNV...
Until the unit is fully charged, the LED status will read half or no charge. Plug the TI3000 GPU-24-UNV into ac power to keep the cells charged whenever it is not in use, even if it is at Full Charge.
Section 4 – Post Operation 4.1 – General Although the TI3000 GPU-24-UNV has been ruggedized and made weather resistant within the scope of unit’s intended use, it is essential that good general care be taken to maintain unit in good operating condition and to maximize unit’s operational life.
Page 27
CAUTION Guard From Incorrect Power Source The TI3000 GPU-24-UNV’s power cells may be damaged if recharged by NiCad or Lithium Ion battery chargers. Power cells should only be charged by either the TI3000 GPU-24-UNV’s internal charger and the ac power cord furnished with the equipment, or when connected to aircraft’s external dc power receptacle.
Do not cut, crush, or drag the input or output power cables when handling the unit. Always inspect cables prior to use. If no damage is evident, proceed to the next step. If damage is evident, contact Tesla™ Customer Service. Do not attempt to use any other type of power cables other than the Tesla™ cables included with the unit.
Ensure proper packaging when returning the unit. Transport the unit only in a sturdy shipping crate or Tesla™ Shipping Case. It is important to enclose the Repair Request Form. Seal the crate on all sides and return it to Tesla™ at the address listed below. Please contact Tesla™ Customer Service at (302) 324-8910 with any questions or concerns.
5. Will a Tesla™ Turbo Start™ spool up a turbine engine? Nothing will start a turbine engine faster or safer than the right Tesla™ Turbo Start™. Not only will it eliminate hot starts, but it will extend the life of your starter, your engine and your battery while reducing maintenance. The Turbo Start™ senses the impedance from the starter/generator.
Page 31
Unit should never be allowed to discharge fully. In-fi eld use, it receives a dc back charge directly from a running engine. When not in use, unit should be plugged into ac power (outlet) all the time. Tesla™ systems will retain 80% of their capacity after one year of storage.
Reset breaker by pressing red button. Reconnect ac and dc connections to the unit. (Plug in ac line cord on military unit.) The unit should power up automatically. If the breaker continues to trip, return the unit to Tesla™ Industries for repair. TI3000 GPU-24-UNV...
If LEDs still do not illuminate, Please contact Tesla™ Customer Service at (302) 324-8910. 2. Unit has no output dc or ac Units cells completely dead. Do a function check with digital meter, input or both.
Page 34
Switch breaker to ON position. Reconnect unit to cables and run. If LEDs still do not illuminate, Please contact Tesla™ Customer Service at (302) 324-8910. 8. Unit does not put out 28.5 Unit is not plugged in. Plug unit into ac power source to volts dc power.
These differences, however, are considered insignifi cant and are not individually accounted for. Ground Support and Aircraft Instrument Variations: The data shown in the performance charts do not account for instrument tolerance differences or inaccuracies. TI3000 GPU-24-UNV...
1200 * * * * * * * * * * * * * * * * * * * * (-29 C Temp) SECONDS Calculations based on actual test data at Pratt-Whitney Canada on 30 March 1992. TI3000 GPU-24-UNV...
Section 8 – Optional Accessories 8.1 – Shipping Case The optional Shipping Case is the safest way to transport the TI3000 GPU-24-UNV. This custom case weighs 23 lbs and comes equipped with side handles and locking latches. TI7000-025 NSN: 8145-01-445-3667 Length: 46.18”...
A rugged combination of advanced composite materials and corrosion-resistant alloys make each plug maximized for durability and connectivity. To extend the life of the Cobra™ Connector included with your unit, replacement contacts, posts, noses and tools can be ordered through the Tesla™ Customer Service. TI2005-238 TI2005-078 Cobra™...
Email: _______________________________________________________________________________________ Purchase Order #: ______________________________________________________________________________ Model #: ____________________________________ Serial #: ________________________________________ Model #: ____________________________________ Serial #: ________________________________________ Shipping method to Tesla™: ______________________________________________________________________ Description of shipping package: ________________________________________________________________ Description of problem: _________________________________________________________________________ _________________________________________________________________________________________________ _________________________________________________________________________________________________ _________________________________________________________________________________________________ Return to Tesla™ 101 Centerpoint Boulevard, New Castle, DE 19720 Attention: Repair Department...
Page 41
Tesla™ 101 Centerpoint Blvd. New Castle, DE 19720 USA Tel: 302-324-8910 Fax: 302-324-8912 9475 Double R Blvd., Suite 2 Reno, NV 89521 Tel: 775-622-8801 Fax: 775-622-8810 www.teslaind.com ♦ www.tesla1.com...
Need help?
Do you have a question about the TI3000 GPU-24-UNV and is the answer not in the manual?
Questions and answers
Hello Hopefully, you are doing well I am looking for Ground Power Universal Unit 3000 FFP Ground Power Universal Unit 3000 Peak Starting Amps: 50 Amps Continuous @ 28.5 Vdc DC NATO Cable Assembly 15ft. AC Line Cord 120 VAC 10ft. AC Line Cord 240 10ft. FOB: Destination MFR PART NR: TI3000 GPU-24UNV PSC CD: 6150 Quantity: 6 Please let me know if you have any questions Please give us the best discounted price, including shipping charges Thank You Hazel Grey Procurement Manager BEST SERVICE PROS, LLC Purchasing Department procurement@bestservicepros.us +1 (929) 487 1019 251-21 JERICHO TURNPIKE, JAMAICA, NY, 11426, USA bestservicepros.us