Technical Specifications - MULTISPAN MSU 1248U Product Manual

8 channel scanner with usb data logger

Advertisement

Product Inception
USB Copy
indication
SCROLL
USB Full Storage
Indication
USB Port
To go to
Parameter
Setting

Technical Specifications

Model
Display
Size (mm)
Panel Cutout
Inputs and
Range
Output
Power Supply
Operating
Temperature
Relative
Humidity
MSU-1248U
SCANNER
5 0 0
7Low
SCROLL
!
R1
R2
T/H
CH
1
2
3
4
H/L
SET
To change the value
or select option
UPPER: 4 Digit 7 seg 0.70",
LOWER: 4 Digit 7 seg 0.50",
100 (H) X 100 (W) X 70 (D) mm
Thermocouple
0 - 10V DC
J
0 to 600°C
0 - 20mA DC
K
0 to 1200°C
4 - 20mA DC
4 Relay (NO-C-NC) 1C/O 5A@230V AC, 5A for resistive load
USB Data Logging Facility
100 to 270V AC,50/60 Hz, Approx 4VA
Up to 95% RH Non Condensing
Page-1
MSU 1248U
R3
R4
5
6
7
8
ENT
MSU 1248U
RED
LED Display
GREEN
92 X 92 mm
Analog input
Range
}
-999 To 9999
0°C To 55°C
Upper Display
(
RED
)
Lower Display
(
GREEN
4 Relay Indication
Alarm Indication
every channel
To save changes
in settings
LED Display
RTD
PT-100/3W -99 to 400°C
PT.1/3W -99.0 to 400.0°C
www.multispanindia.com
)