MULTISPAN MS-1208 Operating Manual

MULTISPAN MS-1208 Operating Manual

8 channel temp scanner

Advertisement

Quick Links

OPERATING MANUAL
8 CHANNEL TEMP. SCANNER
MS-1208
SCANNER
0 0 0 0
CH1
CH 1
CH2
CH3
CH4
SET

Procedure

1) Do all connection as shown in connection diagram.
2) To enter in parameter menu, press set key.
Configure: 1. Scan time
3) If needed to add offset, press
Set offset for each channel if required.
Off set range will be -25°C to + 25°C.
4) Press & Hold
5) In hold mode use
Connection Diagram
MS-1208

Technical Specification

Model
MS 1208
Display
ºC
Size (mm)
Panel Cutout
CH5
Input
CH6
CH7
Range
CH8
Power Supply
ENT
Protection
Level
(As per request)
Operating
Temperature
Relative
Humidity
2. Sensor Selection ( J, K or PT-100 Selectable)
3. Skip or unskip channel
4. DP selection for pt-100 only.
Key for continuous scrolling or manual scrolling.
ENT
&
Key to select next channel.
5
6
1
2
3
4
PT-100/3W
PT-100/3W
-
-
T/C
CH-1
T/C
CH-2
+
+
8 CHANNEL SCANNER (J,K, PT-100)
Range:
'J' : 0 To 600°C
'K' : 0 To 1200°C
PT-100/3W : -99 To 400°C (DP Selectable)
~
~
~
~ 100
100
AUX. SUPPLY
AUX. SUPPLY
100 To
100 To
250V AC
250V AC
+
50/60 Hz
50/60 HZ
250V AC
250V AC
!
4VA
4VA
N
L
Page - 1
UPPER:- 4 Digit 7 seg 0.56", red LED Display
LOWER:- 3 Digit 7 seg 0.4", red LED Display
96 (H) X 96 (W) X 50 (D) mm
92 X 92 mm
J,K,PT-100/3W Selectable
J Type: 0 To 600°C/K Type: 0 To 1200°C/
PT-100: -99 To 400°C (DP Selectable)
100 to 250V AC,50/60 Hz, Approx 4VA
IP-65 (Front side) As per IS/IEC 60529 : 2001
0°C To 55°C
Up to 95% RH Non Condensing
+
together for 5 Sec.
7
8
9
11
10
12
13
PT-100/3W
PT-100/3W
PT-100/3W
-
-
T/C
CH-3
T/C
CH-4
T/C
+
+
+
-
-
CH-8
CH-7
+
+
T/C
T/C
T/C
PT-100/3W
PT-100/3W
PT-100/3W
24
23
22
21
20
19
18
MS-1208
14
15
-
CH-5
-
CH-6
17
16
www.multispanindia.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MS-1208 and is the answer not in the manual?

Questions and answers

Summary of Contents for MULTISPAN MS-1208

  • Page 1 OPERATING MANUAL 8 CHANNEL TEMP. SCANNER MS-1208 Technical Specification Model MS-1208 UPPER:- 4 Digit 7 seg 0.56”, red LED Display MS 1208 SCANNER Display LOWER:- 3 Digit 7 seg 0.4”, red LED Display ºC 0 0 0 0 Size (mm)
  • Page 2 Key Operation 1) Press key to enter in menu. Basic Configuration 2) Press & Key to change the parameter setting. 3) Press Key to set offset. Press key to enter in menu 4) Press & hold key to enter in scroll & hold mode. Display shows scan time use &...
  • Page 3 1) The equipment should be cleaned regularly to avoid blockage of ventilating parts. 2) Clean the equipment with a clean soft cloth. Do not use isopropyl alcohol or any other cleaning agent. 3) Fusible resistor must not be replaced by operator. Page - 3 www.multispanindia.com MS-1208...
  • Page 4 Note: Product improvement and upgrade is a constant procedure. So for more updated operating information and Support, Please contact our Helpline: +91-9978991474/76/82 or Email at service @multispanindia.com Ver: 1809 MS-1208 Page - 4 www.multispanindia.com...

Table of Contents

Save PDF