Procedure

1) Do all connection as shown in connection diagram.
2) To enter in parameter mode, press key combination as per given in chart.
Configure: 1. Grouping facility (Maximum group-4)
3) If needed to add offset, press
Set offset for each channel if required.
Off set range will be -25°C to + 25°C.
4) Press & Hold
5) In hold mode use

Connection Diagram

MS-1248U

Technical Specification

Panel Cutout
Power Supply
(As per request)
Temperature
2. Relay mode (high/low/high & low) for 1 relay per group
- High and Low, High & Trip for 2 relay per group
3. Scan type (Range 0-99 sec)
4. Sensor selection (J,K & PT-100)
5. Skip or unskip channel
6. Dp selection for PT-100/3W Only
Key for continuous scrolling or manual scrolling.
&
Key to select next channel.
PT-100/3W
1
2
3
-
T/C
CH-1
+
NC
~
110
250V AC
50/60 Hz
4VA
L
N
Model
UPPER: 4 Digit 7 seg 0.70 ,red LED Display
Display
LOWER: 3 Digit 7 seg 0.50 ,green LED Display
Size (mm)
96 (H) X 96 (W) X 50 (D) mm
Input
J TYPE, K TYPE,PT-100/3W Selectable
Temperature
J: 0 To 600°C/ K: 0 TO 1200°C/ PT-100:
Range
-99 To 400°C/ PT.1: -99.0 To 400.0°C
Output
4 Relay, (NO-C-NC), 1C/O ,5A, 230V AC /USB
100 to 250V AC,50/60 Hz, Approx 4VA
Protection
IP-65 (Front side) As per IS/IEC 60529 : 2001
Level
Operating
Relative
Up to 95% RH Non Condensing
Humidity
+
together.
PT-100/3W
PT-100/3W
PT-100/3W
5
6
7
8
9
11
4
10
-
-
-
T/C
CH-2
T/C
CH-3
T/C
+
+
+
C
NO
NC
C
NO
NC
C
NO
NC C
R1
R2
R3
-
CH-8
CH-7
+
+
!
T/C
T/C
24
23
22
21
20
PT-100/3W
PT-100/3W
Page - 1
MS-1248
92 X 92 mm
0°C To 55°C
PT-100/3W
12
13
14
15
-
CH-4
T/C
CH-5
+
NO
R4
-
-
CH-6
+
T/C
19
18
17
16
PT-100/3W
www.multispanindia.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MS-1248U and is the answer not in the manual?

Questions and answers

Summary of Contents for MULTISPAN MS-1248U

  • Page 1 OPERATING MANUAL 8 CHANNEL TEMPERATURE SCANNER MS-1248U Technical Specification Model MS-1248 UPPER: 4 Digit 7 seg 0.70 ,red LED Display Display LOWER: 3 Digit 7 seg 0.50 ,green LED Display Size (mm) 96 (H) X 96 (W) X 50 (D) mm...
  • Page 2 Set value change by key.  Press  Hystersis value change by key.  Press  Hystersis value change by key.  Press  Hystersis value change by key.  Press key to save & exit MS-1248U Page - 2 www.multispanindia.com...
  • Page 3 (Repeat the same procedure for all 8 channels) Channel Skip or Unskip using &   Press set key to go to next parameter Dp selection in case of input in pt-100/3W   MS-1248U Page - 3 www.multispanindia.com...
  • Page 4 Press set key to go to next channel  (Repeat the same procedure for all 8 channels)  Change offset point -25 to +25 by using key.   Press set key to go to next channel MS-1248U Page - 4 www.multispanindia.com...
  • Page 5 RTC Second On  Press  RTC Minute  Press   RTC Hour Press  RTC Date  Press  RTC Month  Press   RTC Year Press  Press key to exit MS-1248U Page - 5 www.multispanindia.com...
  • Page 6 1) The equipment should be cleaned regularly to avoid blockage of ventilating parts. 2) Clean the equipment with a clean soft cloth. Do not use isopropyl alcohol or any other cleaning agent. 3) Fusible resistor must not be replaced by operator. MS-1248U Page - 6 www.multispanindia.com...
  • Page 7 Note: Page - 7 MS-1248U www.multispanindia.com...

Table of Contents