Advertisement

Quick Links

Instructions for use
INTRA Endo head L3 – 1.008.1822
INTRA Endo head L3 Y – 1.008.1823

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the INTRA Endo head L3 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for KaVo INTRA Endo head L3

  • Page 1 Instructions for use INTRA Endo head L3 – 1.008.1822 INTRA Endo head L3 Y – 1.008.1823...
  • Page 2 Distributed by: Manufacturer: KaVo Dental GmbH KaVo Dental GmbH Bismarckring 39 Bismarckring 39 88400 Biberach 88400 Biberach Germany Germany Phone +49 7351 56-0 www.kavo.com Fax +49 7351 56-1488...
  • Page 3: Table Of Contents

    Instructions for use INTRA Endo head L3 – 1.008.1822, INTRA Endo head L3 Y – 1.008.1823 Table of contents Table of contents 1 User instructions....................... 2 Safety ..........................2.1 Infection hazard......................7 2.2 Improper use ....................... 7 2.3 Technical condition......................7 2.4 Accessories and combination with other equipment ............
  • Page 4: User Instructions

    Instructions for use INTRA Endo head L3 – 1.008.1822, INTRA Endo head L3 Y – 1.008.1823 1 User instructions 1 User instructions Dear user, Congratulations on purchasing this KaVo quality product. By following the notes below you will be able to work smoothly, economically and safely.
  • Page 5 Instructions for use INTRA Endo head L3 – 1.008.1822, INTRA Endo head L3 Y – 1.008.1823 1 User instructions Serial number Manufacturer UDI symbol Note: Please note accompanying documents Follow the electronic instructions for use HIBC Code CE mark for medical devices...
  • Page 6 Instructions for use INTRA Endo head L3 – 1.008.1822, INTRA Endo head L3 Y – 1.008.1823 1 User instructions WARNING In cases which – if not prevented – can lead to death or severe injury. CAUTION In cases which – if not prevented – can lead to minor or moderate injury.
  • Page 7: Safety

    Instructions for use INTRA Endo head L3 – 1.008.1822, INTRA Endo head L3 Y – 1.008.1823 2 Safety | 2.1 Infection hazard 2 Safety NOTE All serious events occurring in relation to the product must be reported to the manufacturer and the competent authority of the member state, in which the user and/or patient resides.
  • Page 8: Accessories And Combination With Other Equipment

    Instructions for use INTRA Endo head L3 – 1.008.1822, INTRA Endo head L3 Y – 1.008.1823 2 Safety | 2.4 Accessories and combination with other equipment 4 If the following defects occur, stop working and have the service personnel carry out repair work: ▪...
  • Page 9 Instructions for use INTRA Endo head L3 – 1.008.1822, INTRA Endo head L3 Y – 1.008.1823 2 Safety | 2.6 Service and repair ▪ Service technicians of KaVo authorised dealers after the appropriate product training Observe all the following items during servicing work: 4 Have the service and testing tasks carried out according to the Medical Device Operator Ordinance.
  • Page 10: Product Description

    Instructions for use INTRA Endo head L3 – 1.008.1822, INTRA Endo head L3 Y – 1.008.1823 3 Product description | 3 Product description INTRA Endo head L3 (Mat. no. 1.008.1822) INTRA Endo head L3 Y (Mat. no. 1.008.1823) 10 / 28...
  • Page 11: Intended Use

    Instructions for use INTRA Endo head L3 – 1.008.1822, INTRA Endo head L3 Y – 1.008.1823 3 Product description | 3.1 Intended use 3.1 Intended use Indications for use: The medical device is: ▪ Intended for dental treatment only. All other types of use of or modifications to the product are not permitted and can be hazardous.
  • Page 12: Technical Specifications L3

    Instructions for use INTRA Endo head L3 – 1.008.1822, INTRA Endo head L3 Y – 1.008.1823 3 Product description | 3.2 Technical Specifications L3 3.2 Technical Specifications L3 Drive speed max. 3,000 rpm Identification yellow Tool movement is converted into an oscillating motion of approx.
  • Page 13: Startup And Shut Down

    Instructions for use INTRA Endo head L3 – 1.008.1822, INTRA Endo head L3 Y – 1.008.1823 4 Startup and shut down 4 Startup and shut down WARNING Hazard from contaminated products. Patients, users or third parties could be infected by contaminated medical devices.
  • Page 14: Operation

    Instructions for use INTRA Endo head L3 – 1.008.1822, INTRA Endo head L3 Y – 1.008.1823 5 Operation | 5.1 Attaching the medical device 5 Operation WARNING Rotating dental tool. Cuts, infection and burn injury. 4 Never push the press-button while the dental tool is rotating.
  • Page 15: Inserting The Dental Bur

    Instructions for use INTRA Endo head L3 – 1.008.1822, INTRA Endo head L3 Y – 1.008.1823 5 Operation | 5.3 Inserting the dental bur 5.3 Inserting the dental bur NOTE Only use root canal instruments with handles that comply with DIN EN ISO 3630-1: - Handle diameter: 3.5 to 4.0 mm...
  • Page 16: Removing The Dental Bur

    Instructions for use INTRA Endo head L3 – 1.008.1822, INTRA Endo head L3 Y – 1.008.1823 5 Operation | 5.4 Removing the dental bur CAUTION Dental tool shaft slips inside the chucking system due to excessive speed of the dental tool or abrupt engagement of the dental tool.
  • Page 17: Checking For Malfunctions And Troubleshooting

    Instructions for use INTRA Endo head L3 – 1.008.1822, INTRA Endo head L3 Y – 1.008.1823 6 Checking for malfunctions and troubleshooting | 6.1 Checking for malfunctions 6 Checking for malfunctions and troubleshooting 6.1 Checking for malfunctions CAUTION Overheating of the device.
  • Page 18 Instructions for use INTRA Endo head L3 – 1.008.1822, INTRA Endo head L3 Y – 1.008.1823 6 Checking for malfunctions and troubleshooting | 6.2 Troubleshooting 4 Press the O-ring between your fingers to form a loop. 4 Push the O-ring to the front, and remove it.
  • Page 19: Reprocessing Steps In Accordance With Iso 17664-1 / Iso 17664-2

    Instructions for use INTRA Endo head L3 – 1.008.1822, INTRA Endo head L3 Y – 1.008.1823 7 Reprocessing steps in accordance with ISO 17664-1 / ISO 17664-2 | 7.1 Preparations at the site of use 7 Reprocessing steps in accordance with ISO 17664-1 / ISO 17664-2 7.1 Preparations at the site of use...
  • Page 20: Manual Reprocessing

    Instructions for use INTRA Endo head L3 – 1.008.1822, INTRA Endo head L3 Y – 1.008.1823 7 Reprocessing steps in accordance with ISO 17664-1 / ISO 17664-2 | 7.2 Manual reprocessing 7.2 Manual reprocessing WARNING Incomplete disinfection. Patients, users or third parties could be infected by contaminated medical devices.
  • Page 21: Manual Drying

    Instructions for use INTRA Endo head L3 – 1.008.1822, INTRA Endo head L3 Y – 1.008.1823 7 Reprocessing steps in accordance with ISO 17664-1 / ISO 17664-2 | 7.3 Automated reprocessing ▪ Brush, e.g. medium-hard toothbrush 4 Brush off under flowing tap water at least 10 seconds.
  • Page 22: Pre-Cleaning

    Instructions for use INTRA Endo head L3 – 1.008.1822, INTRA Endo head L3 Y – 1.008.1823 7 Reprocessing steps in accordance with ISO 17664-1 / ISO 17664-2 | 7.4 Care products and systems - Servicing CAUTION Never reprocess this medical device in an ultrasonic cleaner.
  • Page 23: Servicing With Kavo Spray

    Instructions for use INTRA Endo head L3 – 1.008.1822, INTRA Endo head L3 Y – 1.008.1823 7 Reprocessing steps in accordance with ISO 17664-1 / ISO 17664-2 | 7.4 Care products and systems - Servicing CAUTION Improper service and care.
  • Page 24: Packaging

    Instructions for use INTRA Endo head L3 – 1.008.1822, INTRA Endo head L3 Y – 1.008.1823 7 Reprocessing steps in accordance with ISO 17664-1 / ISO 17664-2 | 7.5 Packaging 4 Close the front flap and press the chuck service button for at least three seconds until the spray canister control LED flashes three times consecut- ively.
  • Page 25: Storage

    Instructions for use INTRA Endo head L3 – 1.008.1822, INTRA Endo head L3 Y – 1.008.1823 7 Reprocessing steps in accordance with ISO 17664-1 / ISO 17664-2 | 7.7 Storage – at least 10 minutes at 134 C -1 C / +4 C (273 F -1.6...
  • Page 26: Optional Aids And Consumables

    Instructions for use INTRA Endo head L3 – 1.008.1822, INTRA Endo head L3 Y – 1.008.1823 8 Optional aids and consumables 8 Optional aids and consumables Available from specialised dental dealers. Material summary Mat.No. INTRA Instrument stand 3.005.5204 Service coupling for heads (QUATTROcare) 0.411.7941...
  • Page 27: Terms And Conditions Of Warranty

    Instructions for use INTRA Endo head L3 – 1.008.1822, INTRA Endo head L3 Y – 1.008.1823 9 Terms and conditions of warranty 9 Terms and conditions of warranty This KaVo medical device is subject to the following warranty conditions: KaVo grants the end customer a warranty of proper function and guarantees...

This manual is also suitable for:

Intra endo head l3 y1.008.18221.008.1823

Table of Contents