Page 1
Owner’s Information Manual A170030 Fig. 1 – Unit PGB4, WPG5 Our products are designed, tested and built in accordance with DOE standardized procedures; however, actual operating results and efficiencies may vary based on manufacturing and supplier tolerances, equipment configuration, operating conditions and installation practices.
PGB4, WPG5: Owner’s Information Manual Safety Considerations manufacturer’s instructions. For more information about Carbon Monoxide, local laws, or to purchase a CO Alarm, please visit the This unit is equipped with electrically powered safety measures. For the following website https://www.kidde.com...
PGB4, WPG5: Owner’s Information Manual WARNING FIRE, EXPLOSION, ELECTRICAL SHOCK HAZARD Failure to follow this warning could result in personal injury, death and/or property damage. 1. Do not turn off the electrical power to unit without first turning off the gas supply.
PGB4, WPG5: Owner’s Information Manual To start unit electric cooling: Refer to Fig. 6 while proceeding with the following steps. 1. Set the temperature selector on room thermostat to highest temperature setting and set system SWITCH to OFF. 2. Close the external manual shutoff valve, if not already closed.
Page 5
PGB4, WPG5: Owner’s Information Manual MAIN STEP 1 STEP 2 STEP 3 STEP 5 STEP 4 STEP 6 STEP 7 MAIN STEP 8 STEP 9 STEP 10 A07662 Fig. 4 – To Start Unit Gas Heat Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
Page 6
PGB4, WPG5: Owner’s Information Manual MAIN STEP 1 STEP 2 STEP 3 STEP 4 STEP 5 STEP 6 A07663 Fig. 5 – To Shut-off Unit Gas Heat MAIN STEP 2 STEP 4 & 5 STEP 1 STEP 3 A09194 Fig. 6 – To Start Unit Electric Cooling...
PGB4, WPG5: Owner’s Information Manual MAIN STEP 1 STEP 2 STEP 3 A07797 Fig. 7 – To Shut-off Unit Electric Cooling Maintenance and Care for the Equipment Owner filter that was supplied originally by the installer. See Table 1 for filter...
Page 8
PGB4, WPG5: Owner’s Information Manual Compressor CAUTION All compressors are factory shipped with a normal charge of the correct type of refrigeration grade oil. UNIT OPERATION HAZARD Condenser (Outdoor) Fan Failure to follow this caution may result in property damage.
PGB4, WPG5: Owner’s Information Manual CAUTION BURN HAZARD Failure to follow this caution may result in personal injury. Components in heating section may be hot after unit has been started up. When observing flame, be careful not to get close to or touch heating components.
PGB4, WPG5: Owner’s Information Manual Warranty Certificate ) Check to be sure that your thermostat temperature selector is set below the indoor temperature during the cooling season or above the Your unit has a limited warranty. Be sure to read the warranty carefully indoor temperature during heating season.