13.4 seer2 single-packaged air conditioner and gas furnace system with r-410a refrigerant single phase 2-5 nominal tons (sizes 24-60) three phase 3-5 nominal tons (sizes 36-60) (53 pages)
13.4 seer2 single-packaged air conditioner and gas furnace system with r-454b refrigerant single phase 2-5 nominal tons (sizes 24-60) three phase 3-5 nominal tons (sizes 36-60) (47 pages)
LEAVE THE DOORS OPEN WHEN LOADING AND MAKE When having your unit serviced, be sure to specify genuine Carrier SURE THAT NO-ONE REMAINS INSIDE THE REFRIGERAT- Transicold replacement parts for the highest quality and best relia- ED COMPARTMENT WHEN CLOSING THE DOORS.
The power connection is automatically detected by the unit, which 4. DESCRIPTION starts in "Standby" mode after pressing the ON key. 4.2.2. OPERATING MODES 4.1. CAB COMMAND DESCRIPTION The cab command shown in this manual is a multi-tempera- 4.2.2.1. CONTROLLED TEMPERATURE (COOLING & ture model.
5.1.2.1. GUIDELINE CHART 5. OPERATION Standardized exten- 5.1. START THE UNIT Electrical sion cable H.07.RNF protection Power source selection is fully automatic. This is why there Maximum 30m is no button to select the desired mode. A soon as one op- Unit 230V 400V...
5.2. STOP THE UNIT 5.4. START A MANUAL DEFROST MODE Defrost operation is fully automatic from start to finish but, 1. In "Road" mode, switch off the vehicle's ignition. can be manually initiated if required. In "Standby" mode, press the OFF key(s). The start-up parameters can also be changed from automat- 2.
5.5. CHANGE DEFROST PARAMETERS 5.6. DEFROST THE EUTECTIC COMPARTMENT If you wish to return to the compartment temperature display, Frost gradually builds up on the eutectic plates. Unlike a regular either press the ON key or wait 10 seconds. Note that doing evaporator, the defrost sequence is not automatic, but is still crucial so, any changes made WILL NOT be saved.
5.7. DISPLAY UNIT DATA 5.8. SET USER FUNCTION If you wish to return to the compartment temperature display, If you wish to return to the compartment temperature display, either press the ON key or wait 10 seconds. Note that doing either press the ON key or wait 10 seconds.
Fan(s) Several alarms can be triggered at the same time and will remain in active memory until they are cleared. Alarms can be cleared by any Carrier ON (On): The evaporator fan will during Service Center. turn during regulation sequences...
Page 11
MALFUNCTION - RED FLASHES CODE DESCRIPTION ACTION CODE DESCRIPTION ACTION If the problem persists con- The defrost duration exceed- tact the nearest Carrier Ser- ed the normal duration. A vice Center. new defrost sequence is au- Defrost se- A155 tomatically scheduled (if in...
All maintenance services must be done by a technician Units charged with low GWP refrigerant are equipped trained on Carrier Transicold products, respecting all safety with refrigerant detectors that are located in the evapora- and quality standards of Carrier Transicold.
Operating the unit when doors are opened only -18°C are required. may result in frost and increase energy consumption. Carrier al- so offers door switches to shut down the unit automatically when SEPARATE GOODS Do not mix refrigerated and dry goods in loading the van, which reduces the warm air penetration into the the same compartment.
10. ATP AGREEMENT This unit is subject to the Agreement on the International Car- riage of Perishable Foodstuffs and on the Special Equipment to be used for such Carriage (ATP). This refrigeration unit has therefore been approved by the Regional Health Department and is marked with a plate indicating the date of expiration of the approval form.