User Manual
Blood Pressure Monitor
Thank you very much for selecting TRANSTEK Blood Pressure Monitor
TMB-1776-BZY.
Please read the user manual carefully and thoroughtly so as to ensure the safe
usage of this product, Keep the manual well for further reference in case you
have problems.
Version:A/0
Model: TMB-1776-BZY
Arm Type

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TMB-1776-BZY and is the answer not in the manual?

Questions and answers

Summary of Contents for TRANSTEK TMB-1776-BZY

  • Page 1 User Manual Blood Pressure Monitor Model: TMB-1776-BZY Arm Type Thank you very much for selecting TRANSTEK Blood Pressure Monitor TMB-1776-BZY. Guangdong Transtek Medical Electronics Co., Ltd. Please read the user manual carefully and thoroughtly so as to ensure the safe Zone A, No.105 ,Dongli Road, Torch Development District,...
  • Page 2: Table Of Contents

    CATALOGUE Table of Contents INTRODUCTION........................2 General Description Indications for Use Measurement Principle Receiving and Inspecting your Monitor Safety Information LCD Display Signal Monitor Components List BEFORE YOU START......................8 Choice of Power Supply Installing and Replacing the Batteries Setting Date and Time Select the User ID Pair a smart device with the monitor MEASUREMENT........................15...
  • Page 3: Introduction

    The warranty period is two years. component. They are the requirement of standard and using. Readings taken by the TMB-1776-BZY are equivalent to those obtained by a trained observer using the cuff and stethoscope auscultation method.
  • Page 4 INTRODUCTION INTRODUCTION Warning Precaution * This device is intended for indoor, home use and is not intended for self-use in public areas. * Do not apply the cuff on an arm that has an intravenous drip or a blood transfusion attached. * This device is portable, but it is not intended for use during patient transport.
  • Page 5: Lcd Display Signal

    List Current Time Year/Month/Day, Hour : Minute 2. Cuff (Type BF applied part) 1. Blood Pressure Monitor (TMB-1776-BZY) Upper arm cuff:22-32cm or Average value The average value of blood pressure Upper arm cuff:22-42cm. Indicate it is in the memory mode and Memory Query which the group of memory it is.
  • Page 6: Before You Start

    BEFORE YOU START BEFORE YOU START Setting Date and Time. Choice of Power Supply It is important to set the clock before using your blood pressure Battery powered mode: monitor, so that a time stamp can be assigned to each record that is 6VDC 4×AAA batteries stored in the memory.
  • Page 7 BEFORE YOU START BEFORE YOU START Repeat the same steps to set the [HOUR] and [MINUTE]. Repeat the same steps to set the [MONTH] and [DAY]. After setting the [MINUTE], the LCD will display all the settings you Repeat the same steps to set the [time format] between [24 H] and [12 H]. have done, and then display “do nE”...
  • Page 8: Pair A Smart Device With The Monitor

    2. Interference may occur in the vicinity of equipment marked with the following symbol When the monitor is off, press and hold the “START/STOP” button to And TMB-1776-BZY may interfere the vicinal electrical equipment. start pair-up, the bluetooth symbol will flash.
  • Page 9: Applying The Cuff

    BEFORE YOU START MEASUREMENT Applying the cuff Select the User ID Only use a cuff that has been approved by the manufacturer for this device model. Before use, please confirm if it fits your arm circumference. There are 3 user ID available.
  • Page 10: Start The Measurement

    MEASUREMENT MEASUREMENT Start the Measurement 2. Press the “START/STOP” button to turn off the monitor, or it will shut off When the monitor is off, press “START/STOP” button to turn on the monitor, after about 1 minute. and it will finish the whole measurement. (Take user 1 for example.) Cuff wrap detection Inflating and measuring.
  • Page 11: Data Management

    MEASUREMENT DATA MANAGEMENT Recall the Records 4. About the irregular pulse rate and excessive body motion during the measurement. 1. When the monitor is off, press “MEM” button to show the During a measurement, If an irregular pulse rate is detected, the symbol average value of the latest will display in the measurement result.
  • Page 12: Delete The Records

    DATA MANAGEMENT DATA MANAGEMENT Delete the Records B: Delete all records (Example shown below for User 1) Delete the records by following the steps below. 1.Enter the memory recall mode as described in the previous section "Recall the records". A: Delete one record (Example shown below for User 1) 2.Press and hold the “USER”...
  • Page 13: Information For User

    DATA MANAGEMENT INFORMATION FOR USER Tips for Measurement 4. Once deleted, your readings cannot be restored. The LCD will display “--” like the following picture. Measurements may be inaccurate if taken in the following circumstances. Press the “START/STOP” button to turn off the monitor, otherwise it will power off automatically after about 1 minute.
  • Page 14: About Blood Pressure

    ABOUT BLOOD PRESSURE INFORMATION FOR USER What are systolic pressure and diastolic pressure? Maintenance When ventricles contract and pump blood out of the Systolic Diastolic heart, the blood pressure reaches its maximum value blood discharging blood entering In order to get the best performance, please follow the vein artery in the cycle, which is called systolic pressure.
  • Page 15: Why Does My Blood Pressure Fluctuate Throughout The Day

    ABOUT BLOOD PRESSURE TROUBLE SHOOTING If any abnormality arises during use, please check the following points: Why does my blood pressure fluctuate throughout the day? PROBLEM SYMPTOM CHECK THIS REMEDY Batteries are depleted. Replace with new batteries. Display can 1. Individual blood pressure varies No power not light up.
  • Page 16: Specifications

    For more information about our products, please visit www.transtekcorp.com.you can condition at a water vapour pressure up to 50 hPa get customer service, usual problems and customer download, transtek will serve you An atmospheric pressure range of 500 hPa to 1060 hPa anytime.
  • Page 17: Emc Guidance

    RF emissions Standard deviation ≤8mmHg Group 1 CISPR 11 The Basis Safety of the Blood Pressure Monitor (TMB-1776-BZY) is as following: Deviation from normal operation that poses an unacceptable risk to the patient or operator. RF emissions Class [ B ] CISPR 11 Warning: Don’t be near the active HF surgical equipment and the RF shielded room of an...
  • Page 18 EMC GUIDANCE EMC GUIDANCE Table 2 Table 3 Guidance and manufacturer’s declaration – electromagnetic Immunity Guidance and manufacturer’s declaration - electromagnetic Immunity IEC 60601-1-2 Immunity Test Compliance level Compliance Radiated RF Test Band Service Modulation Distance Maximum Test level 60601-1-2 level Frequency (MHz)
  • Page 19: Fcc Statement

    EMC GUIDANCE FCC Statement FCC ID: OU9TMB1776BZY This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.