User Manual
Blood Pressure Monitor
Thank you very much for selecting TRANSTEK Blood Pressure Monitor
TMB-1491.
Please do read the user manual carefully and thoroughtly so as to ensure
the safe usage of this product, and keep the manual well for further
reference in case you have problems.
version:1.0
TMB-1491
Arm Type

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TMB-1491 and is the answer not in the manual?

Questions and answers

Summary of Contents for TRANSTEK TMB-1491

  • Page 1 User Manual Blood Pressure Monitor TMB-1491 Arm Type Thank you very much for selecting TRANSTEK Blood Pressure Monitor TMB-1491. Guangdong Transtek Medical Electronics Co., Ltd. Please do read the user manual carefully and thoroughtly so as to ensure Zone A, No.105 ,Dongli Road, Torch Development District,...
  • Page 2: Table Of Contents

    CATALOGUE CATALOGUE Table of Contents INTRODUCTION.........................2 General Description Indications for Use Measurement Principle Safety Information LCD Display Signal Monitor Components List BEFORE YOU START.......................9 Installing and Replacing the Batteries Setting Date, Time and Measurement Unit Select the User MEASUREMENT......................13 Tie the Cuff Start the Measurement DATA MANAGEMENT......................15 Recall the Records...
  • Page 3: Introduction

    Symbol for “TYPE BF APPLIED two years of reliable service. GUIDE MUST BE READ” PARTS” Readings taken by the TMB-1491 are equivalent to those obtained by a trained observer using the cuff and stethoscope auscultation method. Symbol for “ENVIRONMENT Symbol for “COMPLIES WITH...
  • Page 4 * When measurement, please avoid compression or restriction of the connection tubing. SERVICE PERSONNEL of Transtek. Don’t open or repair the device by yourself in the event of * The device cannot be used with HF surgical equipment at the same time.
  • Page 5: Lcd Display Signal

    INTRODUCTION INTRODUCTION LCD display signal CAUTION * Be careful to strangulation due to cables and hoses, particularly due to excessive length. * At least 30 min required for ME equipment to warm from the minimum storage temperature between uses until it is ready for intended use. At least 30 min required for ME equipment to cool from the maximum storage temperature between uses until it is ready for intended use.
  • Page 6: Monitor Components

    Remove the old batteries from the device following your local recycling guidelines. List 1.Blood Pressure Monitor 2.Cuff (Type BF applied part) (TMB-1491) (22cm~42cm) (Please use TRANSTEK authorized cuff. The size of the actual cuff please refer to the label on the attached cuff.) 3. 4×AAA alkaline batteries...
  • Page 7: Setting Date, Time And Measurement Unit

    BEFORE YOU START BEFORE YOU START Setting Date, Time and Measurement Unit 4.Repeat steps 2 and 3 to set 5.Repeat steps 2 and 3 to set the [HOUR] the [MONTH] and [DAY]. and [MINUTE]. It is important to set the clock before using your blood pressure monitor, so that a time stamp can be assigned to each record that is stored in the memory.
  • Page 8: Select The User

    BEFORE YOU START MEASUREMENT Select the User Tie the cuff .When the monitor is off, press “ SET ” button to enter the selecting user mode, Remove all jewelry, such as watches and then press “ SET ” button again to select the user between User 1 and User 2. bracelets from your left arm.
  • Page 9: Start The Measurement

    MEASUREMENT DATA MANAGEMENT Start the Measurement Recall the Records START 1.When the monitor is off, 1. When the monitor is off, press “START/STOP” button to turn on STOP please press “MEM” button to show the average value of the monitor, and it will finish the whole the latest three records.
  • Page 10: Delete The Records

    DATA MANAGEMENT INFORMATION FOR USER Delete the Records Tips for Measurement If you did not get the correct measurement, you can delete all results by following steps below. 1.Hold pressing “MEM” and “SET ” for 3 seconds when the monitor is in the memory recall mode, the flash display will show.
  • Page 11: About Blood Pressure

    INFORMATION FOR USER ABOUT BLOOD PRESSURE What are systolic pressure and diastolic pressure? Maintenance When ventricles contract and pump blood out Systolic Diastolic In order to get the best performance, please follow the of the heart, the blood pressure reaches its blood entering blood discharging instructions below.
  • Page 12: Why Does My Blood Pressure Fluctuate Throughout The Day

    ABOUT BLOOD PRESSURE TROUBLESHOOTING This section includes a list of error messages and frequently asked Why does my blood pressure questions for problems you may encounter with your blood pressure fluctuate throughout the monitor. If the products not operating as you think it should, check here day? before arranging for service.
  • Page 13: Specifications

    6VDC 4×AAA alkaline batteries For more information about our products, please visit www.transtek.cn.you Display mode Digital LCD V.A.60mm×40.5mm can get customer service, usual problems and customer download, transtek will Measurement mode Oscillographic testing mode serve you anytime. Rated cuff pressure: 0mmHg~299mmHg(0kPa ~ 39.9kPa)
  • Page 14: Complied Standards List

    COMPLIED STANDARDS LIST EMC GUIDANCE Complied Standards List EMC Guidance 1) * This product needs special precautions regarding EMC and needs to be installed EN ISO 14971:2012 / ISO 14971:2007 Medical devices - Risk management and put into service according to the EMC information provided, and this unit can be Application of risk management to medical devices affected by portable and mobile RF communications equipment.
  • Page 15: Emc Guidance

    EMC GUIDANCE EMC GUIDANCE Table 2 Guidance and MANUFACTURER’s declaration – electromagnetic Table 4 Guidance and MANUFACTURER’s declaration – electromagnetic IMMUNITY – for ME EQUIPMENT and ME SYSTEMS that are not LIFE-SUPPORTING IMMUNITY – for all ME EQUIPMENT and ME SYSTEMS Guidance and manufacturer’s declaration –...
  • Page 16 EMC GUIDANCE Table 6 Recommended separation distances between portable and mobile RF communications equipment and the ME EQUIPMENT or ME SYSTEM – for ME EQUIPMENT and ME SYSTEMS that are not LIFE-SUPPORTING Recommended separation distances between portable and mobile RF communications equipment and the device. The device is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled.