TRANSTEK TMB-1583-BS User Manual
Hide thumbs Also See for TMB-1583-BS:

Advertisement

Quick Links

Guangdong Transtek Medical Electronics Co., Ltd.
Zone B, No.105 ,Dongli Road, Torch Development District,
Zhongshan,528437,Guangdong,China
User Manual
Blood Pressure Monitor
Thank you for selecting a TRANSTEK Blood Pressure Monitor.
Please read the user manual carefully and thoroughtly to ensure the safe
usage of this product,Keep the manual well for further reference in case
you have problems.
version:1.0
TMB-1583-BS
Arm Type

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TMB-1583-BS and is the answer not in the manual?

Questions and answers

Summary of Contents for TRANSTEK TMB-1583-BS

  • Page 1 Blood Pressure Monitor TMB-1583-BS Arm Type Thank you for selecting a TRANSTEK Blood Pressure Monitor. Guangdong Transtek Medical Electronics Co., Ltd. Please read the user manual carefully and thoroughtly to ensure the safe Zone B, No.105 ,Dongli Road, Torch Development District,...
  • Page 2: Table Of Contents

    CATALOGUE Table of Contents INTRODUCTION........................2 General Description Indications for Use Contraindications Measurement Principle Safety Information LCD Display Signal Monitor Components List BEFORE YOU START......................9 The Choice of Power Supply Installing and Replacing the Batteries Setting Date, Time and Measurement Unit Select the User Pair-up the Blood Pressure Monitor with Your Device MEASUREMENT........................16...
  • Page 3: Introduction

    Indications for Use The Green Dot is the license symbol of a European network of The Transtek Blood Pressure Monitor is a digital monitor intended for use in industry-funded systems for recycling the packaging materials measuring blood pressure and heartbeat rate with arm circumference ranging of consumer goods.
  • Page 4 INTRODUCTION INTRODUCTION CAUTION CAUTION implanted, electronical devices, patients with pre-eclampsia, premature ventricular beats, was clinically investigated according to the requirements of ISO 81060-2:2013. atrial fibrillation, peripheral, arterial disease and patients undergoing intravascular therapy or arterio-venous shunt or people who received a mastectomy. Please consult your doctor the manufacturer.
  • Page 5 Measurement Unit of the blood pressure Measurement Unit of the blood pressure please contact the SERVICE PERSONNEL of Transtek. Don’t open or repair the device by mmHg yourself in the event of malfunctions. The device must only be serviced, repaired and...
  • Page 6: Monitor Components

    BEFORE YOU START INTRODUCTION The Choice of Power Supply Monitor Components 1.Battery powered mode: 6VDC 4×AAA batteries 2.AC adaptor powered mode: LCD DISPLAY (Please only use the recommended AC AIR HOSE AC adaptor Please unplug the adaptor to depart from the using utility power.
  • Page 7: Setting Date, Time And Measurement Unit

    BEFORE YOU START BEFORE YOU START 4.Repeat step 2 and 3 to set the [MONTH] and [DAY]. Setting Date, Time and Measurement Unit It is important to set the clock before using your blood pressure monitor, so that a time stamp can be assigned to each record that is stored in the memory.
  • Page 8: Select The User

    BEFORE YOU START BEFORE YOU START 6.Repeat step 2 and 3 to set the [UNIT]. Select the User 1.When the monitor is off , press and hold the MEM button to enter user setting mode. The user ID will blink. After UNIT is set, the LCD will display “donE”...
  • Page 9: Pair-Up The Blood Pressure Monitor With Your Device

    CAUTION Interference may occur in the vicinity of equipment marked with the following symbol And TMB-1583-BS may interfering vicinity electrical equipment. MEASUREMENT Sensitive people, including pregnant women pre-eclamptic and those who implanted medical electronic instruments, should avoid using the unit whenever possible.
  • Page 10: Tie The Cuff

    MEASUREMENT MEASUREMENT Start the Measurement Tie the cuff 1.When the monitor is off, press the “START/STOP” button to turn Tie the cuff on your upper arm, then on the monitor, and it will finish the whole measurement. position the tube off-center toward the inner side of arm in line with the little finger.
  • Page 11: Data Management

    DATA MANAGEMENT MEASUREMENT Recall the Records .This device will proceed to data transmission When the monitor is off, after measurement. please press the “MEM” to The Bluetooth symbol show the average value of the blinks on the LCD latest three records.If the indicates data is records are less than three transmitting.
  • Page 12: Delete The Records

    DATA MANAGEMENT SPECIAL FUNCTION About the Lock Button Delete the Records If you did not get the correct measurement, you can delete all The unnecessary keys’ touch will make the blood pressure results by following steps below. (Take user 1 for example) monitor turn on and waste electricity.
  • Page 13: Information For User

    INFORMATION FOR USER INFORMATION FOR USER Tips for Measurement Maintenance Measurements may be inaccurate if taken in the following In order to get the best performance, please follow the circumstances. instructions below. Avoid touching water, Put in a dry place and avoid the sunshine clean it with a dry cloth in case.
  • Page 14: About Blood Pressure

    ABOUT BLOOD PRESSURE ABOUT BLOOD PRESSURE ABOUT BLOOD PRESSURE What are systolic pressure and diastolic pressure? Why does my blood pressure Systolic Diastolic When ventricles contract and pump blood out of the fluctuate throughout the blood discharging blood entering heart, the blood pressure reaches its maximum value vein artery in the cycle, which is called systolic pressure.
  • Page 15: Troubleshooting

    SPECIFICATIONS TROUBLESHOOTING This section includes a list of error messages and frequently Battery powered mode: 6VDC 4×AAA batteries asked questions for problems you may encounter with your blood Power supply AC adaptor powered mode: 6V pressure monitor. If the products not operating as you think it (Please only use the recommended AC should, check here before arranging for servicing.
  • Page 16: Authorized Component

    -- Increase the separation between the equipment and receiver. -- Connect the equipment into an outlet on a circuit different from that to For more information about our products, please visit www.transtek.cn.you can get which the receiver is connected. customer service, usual problems and customer download, transtek will serve you -- Consult the dealer or an experienced radio/TV technician for help.
  • Page 17: Complied Standards List

    Complied Standards List EMC GUIDANCE EMC GUIDANCE EMC GUIDANCE Complied Standards List EMC Guidance EN ISO 14971:2012 / ISO 14971:2007 Medical devices - Risk management Application of risk management to medical devices installed and put into service according to the EMC information provided, EN ISO 15223-1:2016 / ISO 15223-1:2016 Medical devices.
  • Page 18: Emc Guidance

    Complied Standards List EMC GUIDANCE EMC GUIDANCE EMC GUIDANCE Complied Standards List EMC Guidance EN ISO 14971:2012 / ISO 14971:2007 Medical devices - Risk management Application of risk management to medical devices installed and put into service according to the EMC information provided, EN ISO 15223-1:2016 / ISO 15223-1:2016 Medical devices.
  • Page 19 EMC GUIDANCE EMC GUIDANCE EMC GUIDANCE Table 2 Table 3 Guidance and manufacturer’s declaration – electromagnetic immunity Guidance and manufacturer’s declaration – electromagnetic immunity The device is intended for use in the electromagnetic environment specified below. The customer or the The device is intended for use in the electromagnetic environment specified below.
  • Page 20 EMC GUIDANCE EMC GUIDANCE EMC GUIDANCE Table 5 Table 4 Guidance and manufacturer’s declaration - electromagnetic immunity Recommended separation distances between portable and mobile RF communications equipment and the device. The device is intended for use in the electromagnetic environment specified below. The customer or the user of the device, should assure that it is used in such an environment.