Flexiheat R2K RAIN Installation, Use And Maintenance Manual

Condensing boiler, with integrated heat exchanger for domestic hot water production, suitable for outdoor installation

Advertisement

Quick Links

Installation, Use
and Maintenance
Manual for models
R2K RAIN
R2K 24 RAIN / R2K 28 RAIN / R2K 34 RAIN
Condensing boiler, with integrated
heat exchanger for domestic hot
water production, suitable for
outdoor installation
0476
R2K RAIN - RAD - ING - Manual - 2301.1_MIAH4_B3_GPA_A5

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the R2K RAIN and is the answer not in the manual?

Questions and answers

Summary of Contents for Flexiheat R2K RAIN

  • Page 1 Manual for models R2K RAIN R2K 24 RAIN / R2K 28 RAIN / R2K 34 RAIN Condensing boiler, with integrated heat exchanger for domestic hot water production, suitable for outdoor installation 0476 R2K RAIN - RAD - ING - Manual - 2301.1_MIAH4_B3_GPA_A5...
  • Page 2: Table Of Contents

    1.1.17. INSTALLATION MODES 1.1.18. TYPES OF FUME EXHAUST SYSTEMS 2. SERVICE CENTRE SECTION 2.1. FIRST START-UP 2.1.1. PRELIMINARY OPERATIONS FOR FIRST START-UP 2.1.2. BOILER COMMISSIONING 2.1.3. CO2 VALUE CHECK AND CALIBRATION R2K RAIN - RAD - ING - Manual - 2301.1_MIAH4_B3_GPA_A5...
  • Page 3 3.1.7. INFORMATIONAL NOTE ON ANTI-FREEZE FUNCTION 3.1.8. SYSTEM FILLING 3.1.9. FAULT SIGNALLING CODES 3.1.10. ACTIVE FUNCTIONS SIGNALLING CODES 3.1.11. FAST H2O FUNCTION 3.1.12. MAINTENANCE 3.1.13. EXTERNAL CASING CLEANING 3.1.14. DISPOSAL R2K RAIN - RAD - ING - Manual - 2301.1_MIAH4_B3_GPA_A5...
  • Page 4: Introduction

    › On the outer margin of the page It identifies a precaution is placed a thumb index indicating information that must be observed in the type of user to which the R2K RAIN - RAD - ING - Manual - 2301.1_MIAH4_B3_GPA_A5...
  • Page 5 › the right to modify the tools and relative technical documentation without any obligation to third parties; neither will the company be held responsible for any inaccuracies in this handbook deriving from printing translation errors; R2K RAIN - RAD - ING - Manual - 2301.1_MIAH4_B3_GPA_A5...
  • Page 6 All boilers are tested and delivered with a quality certificate signed by the tester. R2K RAIN - RAD - ING - Manual - 2301.1_MIAH4_B3_GPA_A5...
  • Page 7: Installer Section

    1. INSTALLER SECTION 1. INSTALLER SECTION The installation operations described in this section, must be performed only by qualified personnel, having the appropriate technical training in the field for the installation and maintenance of components of civil and industrial domestic hot water production and heating plants.
  • Page 8: Installation

    After having removed the device, value indicated on the data packing, make sure the device is intact. plate. In case of doubt, do not use the device and contact the supplier. R2K RAIN - RAD - ING - Manual - 2301.1_MIAH4_B3_GPA_A5...
  • Page 9: Boiler Location Environmental Requirements

    The ABS material boiler casing according to the indications of the is approved for the exposition good technique. to atmospheric agents and, in particular, to UV rays. R2K RAIN - RAD - ING - Manual - 2301.1_MIAH4_B3_GPA_A5...
  • Page 10: Overall Dimensions

    1. INSTALLATION 1.1.4. OVERALL DIMENSIONS 1.1.5. HYDRAULIC CONNECTIONS HEATING RETURN Ø 3/4 D.H.W. OUTLET Ø 1/2 Ø 3/4 COLD WATER INLET Ø 1/2 HEATING FLOW Ø 3/4 R2K RAIN - RAD - ING - Manual - 2301.1_MIAH4_B3_GPA_A5...
  • Page 11: Positioning And Minimal Technical Spaces

    R2K RAIN - RAD - ING - Manual - 2301.1_MIAH4_B3_GPA_A5...
  • Page 12 1. INSTALLATION WARNING Make sure, using a spirit level, that the boiler is properly inclined being levelled (see fig.3) so as to allow the condensate to drain. fig.3 R2K RAIN - RAD - ING - Manual - 2301.1_MIAH4_B3_GPA_A5...
  • Page 13: Pump Head / Flow Diagram

    1.1.7. PUMP HEAD / FLOW DIAGRAM GPA15-7.5 Pro Z178 p/kPa Q/m³/ h Q/l/s Q/Igpm Q/m³/ h Appliance head losses Fixed head selection button at maximum speed (It disables the control from the PWM) R2K RAIN - RAD - ING - Manual - 2301.1_MIAH4_B3_GPA_A5...
  • Page 14: Hydraulic Connection

    Moreover, it is necessary to install bending and recovery operations a protection security filter of the system. from any off axis positioning that may R2K RAIN - RAD - ING - Manual - 2301.1_MIAH4_B3_GPA_A5...
  • Page 15 The company assumes no liability for damages caused to persons or R2K RAIN - RAD - ING - Manual - 2301.1_MIAH4_B3_GPA_A5...
  • Page 16: System Filling

    1.2 bar (fig. 4); after performing this operation, make sure that the filling tap “R” (fig. 2) is properly closed. open the air relief valves of the radiators and check the air R2K RAIN - RAD - ING - Manual - 2301.1_MIAH4_B3_GPA_A5...
  • Page 17 4 of the water pressure inside the system, open the filling tap “R” once again, until the pressure gauge indicates the value of 1.2 bar (fig. 4). R2K RAIN - RAD - ING - Manual - 2301.1_MIAH4_B3_GPA_A5...
  • Page 18: Filling The Condensate Siphon

    “T” (fig. 5); › Connect the dedicated flexible condensate draining pipe a waste disposal system. The condensate drained directly in the sewerage system by inserting an easily serviceable siphon. R2K RAIN - RAD - ING - Manual - 2301.1_MIAH4_B3_GPA_A5...
  • Page 19: Frost Protection

    If the temperature goes below -10° centigrades, please fill the system with anti-freeze liquid (CLEANPASS FLUIDO AG cod. 98716LA) and insert a frost protection kit (cod. 82259LP). R2K RAIN - RAD - ING - Manual - 2301.1_MIAH4_B3_GPA_A5...
  • Page 20: Gas Connection

    › make sure that the cables section is appropriate for the maximum power absorbed by the boiler and that it is however not lower than 1 mm R2K RAIN - RAD - ING - Manual - 2301.1_MIAH4_B3_GPA_A5...
  • Page 21 (see chapter POWER SUPPLY). WARNING It is strictly forbidden the use of adaptors, multiple plugs and/or extensions for the general power supply of the boiler from the electrical network. R2K RAIN - RAD - ING - Manual - 2301.1_MIAH4_B3_GPA_A5...
  • Page 22: Power Supply

    ”. ·the blue cable to the terminal marked with “N”. ·the brown cable to the terminal marked with “L”. After performing these operations, remount plate “A” and the front casing. R2K RAIN - RAD - ING - Manual - 2301.1_MIAH4_B3_GPA_A5...
  • Page 23: Optional Electrical Connections

    (see chapter ACCESSING THE BOILER); unscrew the screws and remove plate “A” (see fig. 2). › After removing the plate, connect the electrical cables to terminal block “B” (see fig. 2): R2K RAIN - RAD - ING - Manual - 2301.1_MIAH4_B3_GPA_A5...
  • Page 24 P.C.B. and the remote control takes place independently from the boiler’s operating mode and after establishing the connection, the user interface on the P.C.B. is disabled and the display shows the symbol ‘ ’. R2K RAIN - RAD - ING - Manual - 2301.1_MIAH4_B3_GPA_A5...
  • Page 25 P.C.B. placed inside the control panel as follows: DANGER Cut off the voltage from the main switch. › remove the boiler front casing (refer to chapter ACCESSING THE BOILER). R2K RAIN - RAD - ING - Manual - 2301.1_MIAH4_B3_GPA_A5...
  • Page 26 AUXILIARY RELAY GREY TAZ1: ROOM THERMOSTAT ZONE 1 ORANGE TAZ 2: ROOM THERMOSTAT ZONE 2 BLACK VZ1: ZONE VALVE 1 BROWN VZ2: ZONE VALVE 2 BLUE VZR: REMOTE CONTROLLED ZONE VALVE R2K RAIN - RAD - ING - Manual - 2301.1_MIAH4_B3_GPA_A5...
  • Page 27 Upon D.H.W. request through flow-switch, boiler activates in instantaneous mode. HEATING REQUEST – if parameter P01 value is set to ‘5’ (see chapter ‘DIGITECH PARAMETERS R2K RAIN - RAD - ING - Manual - 2301.1_MIAH4_B3_GPA_A5...
  • Page 28: Flue Systems

    › For all air suction ducts, with regard to the air path, you should fig. 1 provide an uphill slope (towards R2K RAIN - RAD - ING - Manual - 2301.1_MIAH4_B3_GPA_A5...
  • Page 29: Installation Modes

    B23P fume exhaust duct; ·have, along its entire length, a section equal to or greater then that of the connection of the device discharge tube; R2K RAIN - RAD - ING - Manual - 2301.1_MIAH4_B3_GPA_A5...
  • Page 30 100 ·they must be realized so as to make sure that the opening inlets obstructed (neither indoors nor outdoors); ·they must be protected with grids, metal meshes, etc. so R2K RAIN - RAD - ING - Manual - 2301.1_MIAH4_B3_GPA_A5...
  • Page 31: Types Of Fume Exhaust Systems

    Subsequent addition of a curve is similar to adding a linear length of tube according to the indications below: co-axial curve Ø80 to 90° = 1.5 m co-axial curve Ø80 to 45° = R2K RAIN - RAD - ING - Manual - 2301.1_MIAH4_B3_GPA_A5...
  • Page 32 Subsequent addition of a curve is similar to adding a linear length of tube according to the indications below: co-axial curve Ø80 to 90° = 1.5 m co-axial curve Ø80 to 45° = 0.8 m R2K RAIN - RAD - ING - Manual - 2301.1_MIAH4_B3_GPA_A5...
  • Page 33 PLEASE NOTE: during the flue analysys tests, place the analyser inside the frontal flue kit terminal slots ‘F’ (fig. SECTION A-A R2K RAIN - RAD - ING - Manual - 2301.1_MIAH4_B3_GPA_A5...
  • Page 35: Service Centre Section

    1. SERVICE CENTRE SECTION 2. SERVICE CENTRE SECTION All operations described below relative to first start-up, maintenance and replacement should be performed only by qualified personnel...
  • Page 36: First Start-Up

    › make sure that the combustion air adduction and fumes and condensate discharge take place properly in compliance with the Local and National Laws and Standards in force; R2K RAIN - RAD - ING - Manual - 2301.1_MIAH4_B3_GPA_A5...
  • Page 37: Boiler Commissioning

    (further 3 minutes), and switch off the power supply and switch it on again. › Open the gas tap. R2K RAIN - RAD - ING - Manual - 2301.1_MIAH4_B3_GPA_A5...
  • Page 38: Co2 Value Check And Calibration

    CO value, turn the screw clockwise and vice-versa if you want to decrease it. Once completed the adjustment, tighten the protection screw ‘A’ (fig. 2) on the Off-Set adjuster. R2K RAIN - RAD - ING - Manual - 2301.1_MIAH4_B3_GPA_A5...
  • Page 39 › Deactivate the chimney sweeper function by selecting the OFF mode by using the key ‘ ’. R2K RAIN - RAD - ING - Manual - 2301.1_MIAH4_B3_GPA_A5...
  • Page 40: Electric Fan Frequency/Heat Capacity Diagram

    2. FIRST START-UP 2.1.4. ELECTRIC FAN FREQUENCY/HEAT CAPACITY DIAGRAM 24 kW FREQUENCY (Hz) MINIMUM MAXIMUM STARTING STEP TYPE FREQUENCY FREQUENCY ADJUSTMENT R2K RAIN - RAD - ING - Manual - 2301.1_MIAH4_B3_GPA_A5...
  • Page 41 2. FIRST START-UP 28 kW FREQUENCY (Hz) MINIMUM MAXIMUM STARTING STEP TYPE FREQUENCY FREQUENCY ADJUSTMENT R2K RAIN - RAD - ING - Manual - 2301.1_MIAH4_B3_GPA_A5...
  • Page 42 2. FIRST START-UP 34 kW FREQUENCY (Hz) MINIMUM MAXIMUM STARTING STEP TYPE FREQUENCY FREQUENCY ADJUSTMENT R2K RAIN - RAD - ING - Manual - 2301.1_MIAH4_B3_GPA_A5...
  • Page 43: Maintenance

    › Check that the system’s water PH is chamber; between 6.5 and 8.5; › if necessary make sure that the combustion is suitably adjusted and R2K RAIN - RAD - ING - Manual - 2301.1_MIAH4_B3_GPA_A5...
  • Page 44 Check that the liquid flow is not obstructed and that there are no combustion gas refluxes inside the internal system; › check the flow and temperature of domestic hot water. R2K RAIN - RAD - ING - Manual - 2301.1_MIAH4_B3_GPA_A5...
  • Page 45: Technical Data

    Efficiency at 100% Heat Input - 30/50°C 105,50 106,43 Efficiency Heat Output min - 30/50°C 104,20 103,60 105,91 Maximum combustion efficiency 97,80 97,70 97,60 Minimum combustion efficiency 98,10 98,20 97,90 R2K RAIN - RAD - ING - Manual - 2301.1_MIAH4_B3_GPA_A5...
  • Page 46 Central heating circuit Temperature setting - Central heating °C 30-80 / 25-45 30-80 / 25-45 30-80 /25-45 Max. operating temperature - Central °C heating Max. operating pressure - Central heating R2K RAIN - RAD - ING - Manual - 2301.1_MIAH4_B3_GPA_A5...
  • Page 47 1/2” 1/2” D.H.W. outlet Ø 1/2” 1/2” 1/2” Ø 3/4” 3/4” 3/4” C.H. Return Ø 3/4” 3/4” 3/4” Flue systems Fan - Max. available pressure Fan - Min. available pressure R2K RAIN - RAD - ING - Manual - 2301.1_MIAH4_B3_GPA_A5...
  • Page 48 Flue bend 45° MF Ø80 - Pressure loss Flue bend 90° MF Ø80 - Pressure loss Flue extension MF Ø80 L=1000 - Pressure loss T-connection MF Ø80 - Pressure loss Gas supply Supply pressure - G20 mbar R2K RAIN - RAD - ING - Manual - 2301.1_MIAH4_B3_GPA_A5...
  • Page 49 Fan speed Max. HEATING output - G31 Fan speed Max. D.H.W. output - G31 Fan speed Min. HEATING output - G31 Fan speed Min. D.H.W. output - G31 Gas consumption - G31 kg/h 1,83 2,17 2,64 R2K RAIN - RAD - ING - Manual - 2301.1_MIAH4_B3_GPA_A5...
  • Page 50 For cogeneration space heaters: Electrical efficiency At rated heat output of cogeneration space heater with supplementary heater disabled η el,CHP100+Sup0 At rated heat output of cogeneration space heater with supplementary heater enabled η el,CHP100+Sup100 R2K RAIN - RAD - ING - Manual - 2301.1_MIAH4_B3_GPA_A5...
  • Page 51 0,000 0,000 Ignition burner power consumption P Emissions of nitrogen oxides NOx mg/kWh Annual energy consumption Q 20513 / 24422 / 29444 / 73,85 87,92 Sound power level, indoors L R2K RAIN - RAD - ING - Manual - 2301.1_MIAH4_B3_GPA_A5...
  • Page 52 (*) High-temperature regime means 60 °C return temperature at heater inlet and 80 °C feed temperature at heater outlet. (**) Low temperature means for condensing boilers 30 °C, for low-temperature boilers 37 °C and for other heaters 50 °C return temperature (at heater inlet). R2K RAIN - RAD - ING - Manual - 2301.1_MIAH4_B3_GPA_A5...
  • Page 53: Technical Assembly

    AIR RELIEF VALVE SIPHON SAFETY VALVE 3 bar 21. DIVERTER VALVE MODULATING PUMP 22. FLOW SWITCH GAS VALVE 10. SYSTEM DRAINING TAP 11. DOMESTIC CIRCUIT PROBE 12. SAFETY THERMOSTAT 13. HEATING PROBE R2K RAIN - RAD - ING - Manual - 2301.1_MIAH4_B3_GPA_A5...
  • Page 54 21. DIVERTER VALVE 8. MODULATING PUMP 22. FLOW SWITCH 9. GAS VALVE 10. SYSTEM DRAINING TAP 11. DOMESTIC CIRCUIT PROBE 12. SAFETY THERMOSTAT 13. HEATING PROBE 14. LIGHT UP ELECTRODE R2K RAIN - RAD - ING - Manual - 2301.1_MIAH4_B3_GPA_A5...
  • Page 55: Hydraulic Board

    16. PROPORTIONAL VENTURI INTEGRATED HEAT 17. CONDENSATE COLLECTION EXCHANGER SIPHON BURNER UNIT 18. DIVERTER VALVE ELECTRIC FAN 19. FLOW SWITCH BY-PASS 20. WATER PRESSURE SWITCH AIR RELIEF VALVE 21. SYSTEM FILLING TAP R2K RAIN - RAD - ING - Manual - 2301.1_MIAH4_B3_GPA_A5...
  • Page 56: Wiring Diagram

    L: LINE GI: YELLOW TRA:START-UP TRANSFORMER SS: DOMESTIC CIRCUIT PROBE N: NEUTRAL BI: WHITE TF: FUMES THERMOFUSE (102°C) EV: ELECTRIC FAN NE: BLACK GR. GREY VD: DIVERTER VALVE SRI: RETURN SENSOR R2K RAIN - RAD - ING - Manual - 2301.1_MIAH4_B3_GPA_A5...
  • Page 57: Accessing The Boiler

    › remove the fastening screws (5) placed on the front edge of the side panel; › grab the bottom of the panel, and remove it by moving it sideways and pulling it upwards. R2K RAIN - RAD - ING - Manual - 2301.1_MIAH4_B3_GPA_A5...
  • Page 58: Accessing The Electronic Board

    (fig. 1) loosening them and turn the panel downwards; › unscrew the four fastening screws 1 - fig. 1; › remove the crankcase pulling it upwards. R2K RAIN - RAD - ING - Manual - 2301.1_MIAH4_B3_GPA_A5...
  • Page 59: System Emptying

    › close the main supply tap of the water supply network; › open all cold and hot water taps; › after completing all operations, close the discharge tap and all previously opened water taps. R2K RAIN - RAD - ING - Manual - 2301.1_MIAH4_B3_GPA_A5...
  • Page 60: Gas Conversion

    (fig.3) is adjusted downwards on the aluminium ring nut (see fig.3); › remount components following demounting operations in reverse making sure that gasket ‘G’ is re-assembled as shown in fig.1; R2K RAIN - RAD - ING - Manual - 2301.1_MIAH4_B3_GPA_A5...
  • Page 61 SELECTION’ from the control panel (see chapters ‘DIGITECH CS PARAMETERS TABLE’ and ‘ACCESSING AND PROGRAMMING THE PARAMETERS’); › adjust the CO2 combustion value as indicated in chapter ‘CO2 VALUE CHECK AND CALIBRATION’. R2K RAIN - RAD - ING - Manual - 2301.1_MIAH4_B3_GPA_A5...
  • Page 63: User Section

    1. USER SECTION 3. USER SECTION The operations described in this section are addressed to all those who will use the machine. The machine must be used and accessed only by qualified operators that fully read and understood the User section, paying particular attention to the warnings.
  • Page 64: Use

    › Close the gas valves; people, animals or property due to › Request immediate intervention of incorrect use. qualified staff. R2K RAIN - RAD - ING - Manual - 2301.1_MIAH4_B3_GPA_A5...
  • Page 65 › DO NOT leave the device exposed to atmospheric agents (rain, sun, etc.) unless specifically intended; › in case of cable damage, turn off the device and contact qualified professional staff to replace it. R2K RAIN - RAD - ING - Manual - 2301.1_MIAH4_B3_GPA_A5...
  • Page 66: Control Panel

    THE LAST 5 FAULTS OPERATING MODE SELECTION KEY: SUMMER / ONLY HEATING / WINTER / OFF RESET KEY: FAULTS RESET - CHIMNEY SWEEP FUNCTION ACTIVATION (HOLD SECONDS) DOMESTIC WATER TEMPERATURE ADJUSTMENT R2K RAIN - RAD - ING - Manual - 2301.1_MIAH4_B3_GPA_A5...
  • Page 67: Display Icons

    INSUFFICIENT SYSTEM WATER PRESSURE SIGNALLING 10. FLAME PRESENT SIGNALLING / IT ALSO INDICATES, ON 3 fig. 2 PERCENTAGE LEVELS, MODULATING POWER LEVEL OF THE BOILER (fig.2) 11. OPERATION DOMESTIC MODE ENABLED R2K RAIN - RAD - ING - Manual - 2301.1_MIAH4_B3_GPA_A5...
  • Page 68: Info Menu Display Data

    BOTTOM AREA PROBE TEMPERATURE [IF AREA BOARD INSTALLED] RETURN PROBE TEMPERATURE SOLAR COLLECTOR TEMPERATURE [IF SOLAR BOARD INSTALLED] (SCS) SOLAR BOILER TEMPERATURE (BOTTOM) [IF SOLAR BOARD INSTALLED] (SBSI) SOLAR BOILER TEMPERATURE (TOP) [IF SOLAR BOARD INSTALLED] (SBSS) R2K RAIN - RAD - ING - Manual - 2301.1_MIAH4_B3_GPA_A5...
  • Page 69 HYBRID DOMESTIC SYSTEM WITH OPTIONAL SENSOR) POWER SUPPLIED BY THE HEATING PUMP IN KW/H (ONLY FOR HYBRID DOMESTIC SYSTEM) HEATING FLOW RATE DISPLAY EXPRESSED IN L/MIN (IF THERE IS A FLOWMETER). R2K RAIN - RAD - ING - Manual - 2301.1_MIAH4_B3_GPA_A5...
  • Page 70: Start-Up

    ’ to decrease the To switch the boiler to ONLY HEATING temperature. operating mode, press the function ·press key ‘ ’ to increase the key ‘ ’, the symbol ‘ ’ will temperature. R2K RAIN - RAD - ING - Manual - 2301.1_MIAH4_B3_GPA_A5...
  • Page 71 (for non condensing models will appear the message ‘OFF’). If the boiler was previously running, it will be turned off and the post- R2K RAIN - RAD - ING - Manual - 2301.1_MIAH4_B3_GPA_A5...
  • Page 72: Informational Note On Anti-Freeze Function

    This function is available only if: › the boiler is powered; › the gas supply is open; › the pressure of the system is proper; › the boiler is not blocked. R2K RAIN - RAD - ING - Manual - 2301.1_MIAH4_B3_GPA_A5...
  • Page 73: System Filling

    2 minutes system relief cycle. Throughout this function the display will show the code “F33”. The boiler can work normally only after completing the operation. fig. 2 R2K RAIN - RAD - ING - Manual - 2301.1_MIAH4_B3_GPA_A5...
  • Page 74: Fault Signalling Codes

    CENTRE. WATER MISSING IF THE SYSTEM PRESSURE IS BELOW 1.2 SYSTEM BAR, FILL THE SYSTEM AS DESCRIBED IN CHAPTER “SYSTEM FILLING”. IF THE BLOCK PERSISTS CONTACT THE TECHNICAL SUPPORT CENTRE. R2K RAIN - RAD - ING - Manual - 2301.1_MIAH4_B3_GPA_A5...
  • Page 75 THE MAIN SWITCH AND THEN RESTORE VOLTAGE / ELECTRICAL NOISE IT, AS SOON AS THE ERROR CODE DUE TO SPARK DISCHARGE DISAPPEARS, BOILER WILL RESTART AUTOMATICALLY. IF THE BLOCK PERSISTS CONTACT THE TECHNICAL SUPPORT CENTRE. R2K RAIN - RAD - ING - Manual - 2301.1_MIAH4_B3_GPA_A5...
  • Page 76 DISAPPEARS FROM THE DISPLAY, THE BOILER WILL START AUTOMATICALLY. SUPPLY VOLTAGE CONTACT THE TECHNICAL SUPPORT CENTRE. COMMUNICATION FAULT CONTACT THE TECHNICAL SUPPORT BETWEEN MODBUS CENTRE. CONTROLLER AND MODBUS CONTROL UNIT R2K RAIN - RAD - ING - Manual - 2301.1_MIAH4_B3_GPA_A5...
  • Page 77: Active Functions Signalling Codes

    › water wastes are limited waiting that the water reaches the right temperature. To activate/deactivate the Fast H2O function please follow the instruction indicated in the paragraph ‘ACTIVE FUNCTIONS SIGNALLING CODES’. R2K RAIN - RAD - ING - Manual - 2301.1_MIAH4_B3_GPA_A5...
  • Page 78: Maintenance

    The use of the symbol WEEE (Waste Electrical Electronic E q u i p m e n t ) R2K RAIN - RAD - ING - Manual - 2301.1_MIAH4_B3_GPA_A5...

This manual is also suitable for:

R2k 24 rainR2k 28 rainR2k 34 rain

Table of Contents