Multiple Rooms - One Lwt Zone - Daikin Altherma 3 R F EHVX04S18E 6V Series Installer's Reference Manual

Hide thumbs Also See for Altherma 3 R F EHVX04S18E 6V Series:
Table of Contents

Advertisement

6.2.2 Multiple rooms – One LWT zone
Underfloor heating or radiators – Thermostatic valves
ERGA04~08E + EHVH/X04+08S18+23E
Daikin Altherma 3 R F
4P629086-1D – 2024.04
Configuration
Setting
Unit temperature control:
#: [2.9]
Code: [C-07]
Number of water temperature zones:
#: [4.4]
Code: [7-02]
External room thermostat for the main
zone:
#: [2.A]
Code: [C-05]
Benefits
Cooling. Heat pump convectors provide, besides heating capacity, also excellent
cooling capacity.
Efficiency. Underfloor heating has the best performance with the heat pump
system.
Comfort. The combination of the two heat emitter types provides:
-
The excellent heating comfort of the underfloor heating
-
The excellent cooling comfort of the heat pump convectors
If only one leaving water temperature zone is needed because the design leaving
water temperature of all heat emitters is the same, you do NOT need a mixing
valve station (cost effective).
Example: If the heat pump system is used to heat up one floor where all the rooms
have the same heat emitters.
If you are heating up rooms with underfloor heating or radiators, a very common
way is to control the temperature of the main room by using a thermostat (this can
either be the user interface or an external room thermostat), while the other
rooms are controlled by so-called thermostatic valves, which open or close
depending on the room temperature.
Setup
6
|
1 (External room thermostat):
Unit operation is decided by the
external thermostat.
0 (Single zone): Main
1 (1 contact): When the used
external room thermostat or heat pump
convector can only send a thermo ON/
OFF condition. No separation between
heating or cooling demand.
A
B
C
T
a
Application guidelines
Value
Installer reference guide
37

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Altherma 3 R F EHVX04S18E 6V Series and is the answer not in the manual?

Table of Contents