Daikin Altherma 3 R F+W EHBH04E 6V Series Operation Manual

Daikin Altherma 3 R F+W EHBH04E 6V Series Operation Manual

Hide thumbs Also See for Altherma 3 R F+W EHBH04E 6V Series:

Advertisement

Quick Links

Operation manual
Daikin Altherma 3 R F+W
EHBH04E*6V
EHBH08E*6V
EHBH08E*9W
EHBX04E*6V
EHBX08E*6V
EHBX08E*9W
EHVH04S(U)18E*6V
EHVH04S(U)23E*6V
EHVH08S(U)18E*6V
EHVH08S(U)23E*6V
EHVH08S18E*9W
EHVH08S23E*9W
EHVX04S18E*3V
EHVX04S18E*6V
EHVX04S23E*3V
EHVX04S23E*6V
EHVX08S18E*6V
EHVX08S23E*6V
Operation manual
EHVX08S18E*9W
English
Daikin Altherma 3 R F+W
EHVX08S23E*9W

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Altherma 3 R F+W EHBH04E 6V Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Daikin Altherma 3 R F+W EHBH04E 6V Series

  • Page 1 Operation manual Daikin Altherma 3 R F+W EHBH04E*6V EHBH08E*6V EHBH08E*9W EHBX04E*6V EHBX08E*6V EHBX08E*9W EHVH04S(U)18E*6V EHVH04S(U)23E*6V EHVH08S(U)18E*6V EHVH08S(U)23E*6V EHVH08S18E*9W EHVH08S23E*9W EHVX04S18E*3V EHVX04S18E*6V EHVX04S23E*3V EHVX04S23E*6V EHVX08S18E*6V EHVX08S23E*6V Operation manual EHVX08S18E*9W English Daikin Altherma 3 R F+W EHVX08S23E*9W...
  • Page 2: Table Of Contents

    Latest revisions of the supplied documentation may be available on Symptom: You are feeling too cold (hot) in your living room..19 the regional Daikin website or via your installer. Symptom: The water at the tap is too cold ........ 19 Symptom: Heat pump failure.............
  • Page 3: User Safety Instructions

    Waste batteries must be treated at a specialized treatment facility for reuse. By ensuring waste batteries are disposed of correctly, you will help to prevent potential negative consequences for the environment and human health. EHBH/X04+08EA/EF + EHVH/X04+08S(U)18+23EA/EJ Operation manual Daikin Altherma 3 R F+W 4P642728-1A – 2021.02...
  • Page 4: Instructions For Safe Operation

    Before you purge air from heat emitters or collectors, check if is displayed on the home screen of the user interface. ▪ If not, you can purge air immediately. Operation manual EHBH/X04+08EA/EF + EHVH/X04+08S(U)18+23EA/EJ Daikin Altherma 3 R F+W 4P642728-1A – 2021.02...
  • Page 5: Quick Guide

    Water pipe freeze prevention. Even if you turn OFF space heating/cooling operation ([C.2]: Operation > Space heating/cooling), water pipe freeze prevention – if enabled– will remain active. EHBH/X04+08EA/EF + EHVH/X04+08S(U)18+23EA/EJ Operation manual Daikin Altherma 3 R F+W 4P642728-1A – 2021.02...
  • Page 6: Domestic Hot Water

    Increase or decrease the slope/offset. When slope is selected: set slope and go to offset. When offset is selected: set offset. Confirm changes and return to the submenu. Operation manual EHBH/X04+08EA/EF + EHVH/X04+08S(U)18+23EA/EJ Daikin Altherma 3 R F+W 4P642728-1A – 2021.02...
  • Page 7: Operation

    The LEDs of the status indicator light up or blink to show the operating mode of the unit. Mode Description Blinking blue Standby The unit is not in operation. Continuous blue Operation The unit is in operation. EHBH/X04+08EA/EF + EHVH/X04+08S(U)18+23EA/EJ Operation manual Daikin Altherma 3 R F+W 4P642728-1A – 2021.02...
  • Page 8: Menu Structure: Overview User Settings

    Only applicable for reversible models, or heating only models + conversion kit (**) Only accessible by installer (***) Only applicable when WLAN is installed INFORMATION Depending on the selected installer settings and unit type, settings will be visible/invisible. Operation manual EHBH/X04+08EA/EF + EHVH/X04+08S(U)18+23EA/EJ Daikin Altherma 3 R F+W 4P642728-1A – 2021.02...
  • Page 9: Possible Screens: Overview

    Go through the list of the main menu. Go to the main menu screen. Holiday mode Enable/disable breadcrumbs. Holiday mode active Item Description a Domestic hot water Domestic hot water Measured tank temperature EHBH/X04+08EA/EF + EHVH/X04+08S(U)18+23EA/EJ Operation manual Daikin Altherma 3 R F+W 4P642728-1A – 2021.02...
  • Page 10: Main Menu Screen

    Shows the applicable symbol Adjust and automatically apply the desired for your additional zone emitter type. temperature. Set the leaving water temperature for the additional zone (if present). Operation manual EHBH/X04+08EA/EF + EHVH/X04+08S(U)18+23EA/EJ Daikin Altherma 3 R F+W 4P642728-1A – 2021.02...
  • Page 11: Detailed Screen With Values

    Space heating/cooling operation ON Space heating/cooling operation OFF 2 Set operation to On or Off. Reading out information To read out information 1 Go to [8]: Information. EHBH/X04+08EA/EF + EHVH/X04+08S(U)18+23EA/EJ Operation manual Daikin Altherma 3 R F+W 4P642728-1A – 2021.02...
  • Page 12: Space Heating/Cooling Control

    To restrict automatic changeover according to a schedule Conditions: You set the space operation mode to Automatic. 1 Go to [4.2]: Space heating/cooling > Operation mode schedule. 2 Select a month. Operation manual EHBH/X04+08EA/EF + EHVH/X04+08S(U)18+23EA/EJ Daikin Altherma 3 R F+W 4P642728-1A – 2021.02...
  • Page 13: Domestic Hot Water Control

    Powerful operation allows the domestic hot water to be heated by the backup heater or booster heater. Use this mode on days when there is more hot water usage than usual. EHBH/X04+08EA/EF + EHVH/X04+08S(U)18+23EA/EJ Operation manual Daikin Altherma 3 R F+W 4P642728-1A – 2021.02...
  • Page 14: Schedule Screen: Example

    In this example, Monday is the first day you programmed. Thus, the last programmed action is valid up to the first action of next Monday. Operation manual EHBH/X04+08EA/EF + EHVH/X04+08S(U)18+23EA/EJ Daikin Altherma 3 R F+W 4P642728-1A – 2021.02...
  • Page 15: Weather-Dependent Curve

    5 Select Saturday. the curve can be adjusted by an installer or user. 6 Select Copy. EHBH/X04+08EA/EF + EHVH/X04+08S(U)18+23EA/EJ Operation manual Daikin Altherma 3 R F+W 4P642728-1A – 2021.02...
  • Page 16: 2-Points Curve

    Possible actions on this screen X1, X2 Examples of outdoor ambient temperature Go through the temperatures. Change the temperature. Go to the next temperature. Confirm changes and proceed. Operation manual EHBH/X04+08EA/EF + EHVH/X04+08S(U)18+23EA/EJ Daikin Altherma 3 R F+W 4P642728-1A – 2021.02...
  • Page 17: Using Weather-Dependent Curves

    It will take more time and energy to heat up/cool Additional zone – Cooling [3.6] Additional zone > down the room again. Cooling WD curve EHBH/X04+08EA/EF + EHVH/X04+08S(U)18+23EA/EJ Operation manual Daikin Altherma 3 R F+W 4P642728-1A – 2021.02...
  • Page 18: Maintenance And Service

    The refrigerant inside this unit is mildly flammable. WARNING The appliance shall be stored in a room without continuously operating ignition sources (example: open flames, an operating gas appliance or an operating electric heater). Operation manual EHBH/X04+08EA/EF + EHVH/X04+08S(U)18+23EA/EJ Daikin Altherma 3 R F+W 4P642728-1A – 2021.02...
  • Page 19: Symptom: You Are Feeling Too Cold (Hot) In Your Living Room

    ▪ For EHBH/X: The backup heater automatically takes over the heat load, and the booster heater in the optional tank takes over the domestic hot water production. EHBH/X04+08EA/EF + EHVH/X04+08S(U)18+23EA/EJ Operation manual Daikin Altherma 3 R F+W 4P642728-1A – 2021.02...
  • Page 20: Disposal

    Additional capacity step 2 [9.3.5] (if applicable) Main zone Emitter type [2.7] Control [2.9] Setpoint mode [2.4] Schedule [2.1] WD curve type [2.E] Additional zone (only if [4.4]=1, dual zone) Operation manual EHBH/X04+08EA/EF + EHVH/X04+08S(U)18+23EA/EJ Daikin Altherma 3 R F+W 4P642728-1A – 2021.02...
  • Page 24 4P642728-1 A 0000000% 4P642728-1A 2021.02 Verantwortung für Energie und Umwelt...

Table of Contents