Download Print this page
Midtronics RIVIAN CPX-900 Quick Reference Manual
Midtronics RIVIAN CPX-900 Quick Reference Manual

Midtronics RIVIAN CPX-900 Quick Reference Manual

Battery & electrical diagnostic analyzer
Hide thumbs Also See for RIVIAN CPX-900:

Advertisement

Quick Links

Important - Before You Start
• Before operating the analyzer, refer to Instruction Manual
• Always follow battery manufacturer instructions and BCI
(Battery Council International) safety recommendations
• For additional support go to support.cpx900.com
Consent to Collection and Use of Data:
You agree that Midtronics, Inc. may collect, store, transmit,
and use technical data and related information, including but
not limited to technical information about this device, system
and application software, and accessories, that is gathered
periodically to facilitate the provision of product support,
product improvements, product development, and other
services related to use of this device. If electing to collect
personal data (such as e-mail addresses) the user is solely
responsible for obtaining any necessary permissions, and agrees
to indemnify and hold harmless Midtronics, Inc. Its subsidiaries,
officers, employees and agents from any liability associated with
collecting, storing, and transmitting such personal data.
Safety Power Capacity™ (SPC™)
The testing process uses proprietary 12V Safety Power Capac-
ity™ (SPC™) diagnostic technology to determine the battery
State of Charge and Reserve Capacity. This additional analysis
can take up to 60 seconds to complete
IMPORTANT: Always begin each test by connecting the
tester clamps to the battery being tested. The testing
process begins as soon as the clamps are connected.
Connections And Data Ports
 
 
 
 
 
www.midtronics.com
RIVIAN CPX-900
Battery & Electrical Diagnostic Analyzer
Display Screen
  
Cooling Vent
 
Arrow Keys &
Power Button
 
Micro-USB Port
Thermal Printer
(optional)
 
Temperature
Sensor
VIN Barcode
 
User-replace-
Scanner
able AA batter-
(optional)
ies
Clamp Tabs
User-replace-
able test
clamps
Main Menu
12.74V
In Vehicle Test Out of Vehicle
Messages
Menu Bar
Battery Voltage
12.74V
(if connected)
Bluetooth
connectivity status
Main Menu Selection Area
When displayed, the Screen Arrows show which ARROW
key on the keypad to press to display other icons, screens,
or item in a list.
Additional Screens
The dots at the bottom or side of a menu or results screen
indicate additional screens are available.
Screen 1
 
Press  or 
Screen 2
 Screen 3
 
Test Preparation
Before starting the test visually inspect the battery for:
Cracked, buckled, or leaking case.
Corroded, loose, or damaged cables and connections.
Corrosion, dirt, or acid on the battery terminals or case top.
Corroded or loose battery tray and hold-down fixture.
Risk of explosive gases
Batteries generate explosive gases
during normal operation, and when
discharged or charged. Follow all
manufacturers' instructions and
BCI (Battery Council International)
safety recommendations.
Before Testing:
Disconnect First Responder Loop and Ground Cables.
Midtronics Inc.
7000 Monroe Street Willowbrook, IL 60527
Quick Reference Guide
Page
Quick Reference Guide
April, 2023
167-001100EN-A
167-001100EN-A
April, 2023
CPX-900
History
Test
 
Version
Settings
WiFi signal strength
Controller internal
battery status
Screen 1
Press  or 
Screen 2
Wash hands after handling.
REQUIRED BY CALIFORNIA PROP. 65:
Battery posts, terminals, and related
accessories contain lead and lead
compounds, chemicals known to the
state of California to cause cancer
and birth defects or other reproduc-
tive harm.
1

Advertisement

loading
Need help?

Need help?

Do you have a question about the RIVIAN CPX-900 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Midtronics RIVIAN CPX-900

  • Page 1 • For additional support go to support.cpx900.com In Vehicle Test Out of Vehicle Test   Consent to Collection and Use of Data: You agree that Midtronics, Inc. may collect, store, transmit, Messages Version Settings and use technical data and related information, including but not limited to technical information about this device, system ...
  • Page 2 Insufficient data to Yellow: Yellow: Gray: Gray: may require further perform the test. testing. Refer to Appendix B: Decision Tables in the User Manual for a complete explanation of all possible test results. Midtronics Inc. 7000 Monroe Street Willowbrook, IL 60527 www.midtronics.com...
  • Page 3 13. Test Results - PRIMARY and SECONDARY BATTERY Test Re- sults will be displayed, following the Secondary battery test. 14. Result Variability (Single or Dual Battery) - The screens below represent other test results that may return. www.midtronics.com Midtronics Inc. 7000 Monroe Street Willowbrook, IL 60527...
  • Page 4 Serving Europe, Africa, the Middle Phone: +86 755 2374 1010 Asia/Pací c (excluding China) Canadian Inquiries East, and The Netherlands Contact Corporate Headquarters Toll Free: +1 1 866 592 8052 Phone: +31 306 868 150 Phone: +1.630.323.2800 167-001100EN-A ©2023 Midtronics, INc. All Rights Reserved...