www.intertec.info 1 General .................................. 3 2 Use................................... 3 3 Specific conditions for use ........................... 3 4 Explanation of symbols for warnings and signal words .................. 3 5 Safety information.............................. 4 6 Technical Data ................................ 4 7 Installation ................................ 5 8 Connection................................ 5 9 Commissioning ..............................
Operating Instructions CP SLIMTHERM DG.A General Specific conditions for use 1. The connecting lead shall be installed to provide for These operating instructions describe the safe and permanent wiring and adequate protection against proper way to work with the device. The safety mechanical damage.
Operating Instructions CP SLIMTHERM DG.A Permitted operating voltage max. 275 V AC NOTICE Rated current (in max. 10 A compliance with VDE 0298) NOTE Ambient temperature - 60 to + 60°C It is essential to pay attention to this safety advice as you Max.
Operating Instructions CP SLIMTHERM DG.A Installation NOTICE Carefully remove When removing from the packaging and during transport, the connection line must not be stressed or bent. Modifications and repairs may only be carried out by the manufacturer. The optimum installation position of the SLIMTHERM...
Page 6
Operating Instructions CP SLIMTHERM DG.A integrated thermostat, the fuse protection can be selected according to the cross-section of the supply cable. Additional equipotential bonding is required. The terminal block designated for this purpose has the ground sign. Junction box...
Operating Instructions CP SLIMTHERM DG.A CAUTION Sufficient heat dissipation must be ensured. Unauthorized covers must be removed as otherwise there is the risk of the heater overheating. Terminal box The heating circuit is permanently disconnected by a temperature melt fuse which can't be reset if these installation instructions are not adhered to.
Operating Instructions CP SLIMTHERM DG.A If the heater fails, check the installation. Carry out a NOTICE continuity test on the heating circuit. Pay attention to the connection diagram switching point Environmental damage may be caused if thermostat! disposed of incorrectly!
Operating Instructions CP SLIMTHERM DG.A Dipl.-Ing. Martin Hess, Managing Director Further information and service If the information contained in this instruction manual should not be sufficient in any way, then INTERTEC would be glad to be at your disposal to provide further information and service.