Intertec Data Systems CP MEGATHERM D.A HI series Operating Instructions Manual

Advertisement

Quick Links

Operating Instructions
CP MEGATHERM D.A HI
HOM160989579Ien-1 • 01/06/2017

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CP MEGATHERM D.A HI series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Intertec Data Systems CP MEGATHERM D.A HI series

  • Page 1 Operating Instructions CP MEGATHERM D.A HI HOM160989579Ien-1 • 01/06/2017...
  • Page 2: Table Of Contents

    www.intertec.info Table of contents 1 General .................................. 3 2 Use ...................................  3 3 Explanation of symbols for warnings and signal words .................. 3 4 Safety information .............................. 3 5 Installation accessories ............................ 4 6 Technical Data ................................  4 7 Installation................................ 4 8 Connection................................
  • Page 3: General

    www.intertec.info Operating Instructions CP MEGATHERM D.A HI Safety information can be found at the start of the General chapter before the instructions which may lead to a haz- These operating instructions describe the safe and ardous situation. Additional safety information can be proper way to work with the device.
  • Page 4: Installation Accessories

    www.intertec.info Operating Instructions CP MEGATHERM D.A HI Profile type "P" Height x 225 x 229 x 60 CAUTION Width x Depth Risk of burns from a hot surface Attainable highest temperatures: INFO - Max. 160°C with T3 heating systems You will find the precise technical data for your in- - Max.
  • Page 5: Connection

    www.intertec.info Operating Instructions CP MEGATHERM D.A HI In the dust Ex area, the applicable requirements of EN For protection against short circuit and line protection 60079-14 must be complied with. you can use circuit breakers up to 10 A. Additional equipotential bonding is required. The ter- minal block designated for this purpose has the ground sign.
  • Page 6: Commissioning

    www.intertec.info Operating Instructions CP MEGATHERM D.A HI Repairs may only be carried out by the manufacturer in the factory. In the dust Ex area, the applicable requirements of EN 60079-17 and EN 60079-19 must be complied with. Ground RS 485 TC DIGITAL Troubleshooting If the heater fails, check the installation.
  • Page 7: 14 Ec Declaration Of Conformity

    www.intertec.info Operating Instructions CP MEGATHERM D.A HI Further information and service NOTICE If the information contained in this instruction manual Environmental damage may be caused if dis- should not be sufficient in any way, then INTERTEC would be glad to be at your disposal to provide further in- posed of incorrectly! formation and service.