Intertec Data Systems CP MICROTHERM DENA Operating Instructions Manual

Advertisement

Quick Links

Operating Instructions
CP MICROTHERM DENA
HOM180473483Ien-3 • 11/02/2020

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CP MICROTHERM DENA and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Intertec Data Systems CP MICROTHERM DENA

  • Page 1 Operating Instructions CP MICROTHERM DENA HOM180473483Ien-3 • 11/02/2020...
  • Page 2: Table Of Contents

    www.intertec.info Table of contents 1 General .................................. 3 2 Use ...................................  3 3 Explanation of symbols for warnings and signal words .................. 3 4 Safety information .............................. 3 5 Installation accessories ............................ 4 6 Technical Data ................................  4 7 Installation................................ 4 8 Connection................................
  • Page 3: General

    Operating Instructions CP MICROTHERM DENA General DANGER These operating instructions describe the safe and proper way to work with the device. The safety informa- DANGER tion and instructions given as well as the local accident This sign is warning about an extremely hazardous situ-...
  • Page 4: Installation Accessories

    Operating Instructions CP MICROTHERM DENA Material Seawater-proof alu- CAUTION minium, black anodized Mean Time Before Failure 50.000 h Risk of burns from a hot surface Storage temperature - 60 to + 80°C Attainable highest temperatures: Special voltages with corresponding power adjustment - Max.
  • Page 5: Connection

    Operating Instructions CP MICROTHERM DENA ATTENTION: Never remove the adapter/ cable gland! Illustration 2: Example heater with KLE connection CAUTION NOTICE: Do not remove adapter/ cable connec- tion to connect up the heater! This would cause irreversible damage to the heater and this would mean that the explosion protection can no longer be warranted.
  • Page 6: Commissioning

    Operating Instructions CP MICROTHERM DENA Repairs may only be carried out by the manufacturer in the factory. All components have to be kept clean and free of dust and harmful substances that could lead to excessive temperature rise. In the dust Ex area, the applicable requirements of KS C Terminal box IEC 60079-17 must be complied with.
  • Page 7 Operating Instructions CP MICROTHERM DENA • Sort other components according to their material properties and dispose of them. NOTICE Environmental damage may be caused if dis- Dipl.-Ing. Martin Hess, Managing Director posed of incorrectly! Electrical scrap and electronics components are subject...

Table of Contents