MOS GB 0324-1
FIGHTER 310P
INSTALLATION AND MAINTENANCE INSTRUCTIONS
R
611863
2
1
bar
3
0
T
G
4
FIGHTER 310P
1
-5
R
+5

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FIGHTER 310P and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Nibe FIGHTER 310P

  • Page 1 INSTALLATION AND MAINTENANCE INSTRUCTIONS FIGHTER 310P MOS GB 0324-1 611863 FIGHTER 310P...
  • Page 3: Table Of Contents

    Maximum boiler and radiator volumes ....10 Heating curve offset +2 ........18 Inspection of the installation ........ 10 Setting using diagrams ........18 Temperatures in FIGHTER 310P ......10 Dealing with malfunctions Pipe connections Low temperature or a lack of hot water ....19 General ..............
  • Page 4: General

    In order to get the ultimate benefit from your heat pump FIGHTER 310P you should read through the For Home Owners section in this Installation and Maintenance Instruction”. FIGHTER 310P is an exhaust air heat pump. This means that collects...
  • Page 5: System Description

    For Home Owners System description Principle of operation Exhaust air Vented air FIGHTER 310P comprises an electric boiler with a Frånluft Avluft copper lined water heater and a heat pump which recovers energy from the ventilation air. The recov- ered energy is supplied to the heat pump. The heat pump must be installed in a ventilation system intend- ed for mechanical exhaust air.
  • Page 6: Front Panel

    A02 = Frysrisk tilluftsbatteri Växjö 12 (6) Säkerhetsventil, värmesystem: Halmstad 11 (5) överhettningsskydd A03 = Kompressorskydd utlöst Markaryd Kalmar Motioneras regelbundet genom att Helsingborg Karlskrona Hässleholm ratten vrids försiktigt motsols. Malmö Simrishamn Efterfyll värmesystemet vid behov. Ystad 11 (5) Se skötselanvisning. FIGHTER 310P...
  • Page 7: Functions On The Front Panel

    In this mode, the Heating curve selection built-in lamp flashes. Use the “Heating curve selection” knob to set Pressing the button again resets the above the automatic heating control system; see functions. under “Room temperature”. FIGHTER 310P...
  • Page 8: Room Temperature Automatic Heating Control System

    11 (5) in the room temperature. NOTE! An increase in the room temperature may be inhibited by the radiator or floor heating thermostats, if so these must be turned up. FIGHTER 310P...
  • Page 9: Basic Values For The Automatic Heating Control System

    ** Floor heating can be dimensioned very differently. Examples 2 and 3 above refer to a system where the flow temperature needs to be approximately 35 - 40 °C resp 45 - 50 °C on the coldest day. FIGHTER 310P...
  • Page 10: Maintenance Routines Cleaning The Air Filter

    Pull out the holder, take out the filter and shake off any dirt. Check that the filter is not damaged. New original filters can be ordered from NIBE. Assembly takes place in the reverse order. The interval between cleaning operations varies and depends on the amount of dust in the exhaust air.
  • Page 11: Cleaning The Ventilation Devices

    “Dealing with malfunctions” ”High extract air tempera- ture”. It is normal that the extract air temperature varies. FIGHTER 310P has two safety valves, one for the heating system and one for the water heater. The heating system safety valve (52) must be com-...
  • Page 12: General Points For The Installation Engineer

    Temperatures in FIGHTER 310P and in doing so reduce the risk of leak- age. Normal temperature levels in boiler or water heater.
  • Page 13: Pipe Connections

    The total volume is 240 litres, with 170 litres in the information. water heater and 70 litres in the double-jacket space. The pressure vessel in the FIGHTER 310P is approved for max 9.0 bar (0.9 MPa) in the water heater and 2.5 bar (0.25 MPa) in the double jacket space.
  • Page 14: Ventilation Connection

    Ventilation connection Ventilation flow Duct installation FIGHTER 310P is connected so that all ventilation air To prevent fan noise being transferred to the exhaust except the kitchen fan passes the evaporator (62) in air devices, it may be a good idea to install a silencer the heat pump.
  • Page 15: Electrical Connections

    If a conduit is used it must be sealed to prevent con- The electrical installation and wiring densation in the sensor capsule. must conform to current regulations. UTEGIVARE RUMSGIVARE RUNDSTYRNING – ÄR BÖR – – SKYDDSKLENSPÄNNING SELV FIGHTER 310P...
  • Page 16: Setting The Fan Capacity

    Se instruktion bakom luckan! Once the piece of rubber has been removed the immersion heater is only permitted to run when the compressor is operational (except in defrosting mode). In addition, the flow temperature is limited to maximum 60 °C. FIGHTER 310P...
  • Page 17: Centralised Load Control And Load Monitor

    If both a load sensor and centralised load control are to be used, the contact functions must be the same for both (both make or both break). The contacts must be connected in parallel for make contact function and in series for break contact function. FIGHTER 310P...
  • Page 18: Preparations

    (52). The that the switch is not in an intermediate position. filling valve is then closed (49). Turn the safety valve (52) until the boiler pressure reaches the normal working range (0.5 - 1.5 bar). FIGHTER 310P...
  • Page 19: Setting The Ventilation

    (74) on system can be set as required. See the section “Room the hot water side and pull out the pipe. temperature” “Setting the Automatic heating control system” and “Front panel”. FIGHTER 310P...
  • Page 20: Setting The Automatic Heating Control System

    For the Installer Setting the automatic heating control system Heating curve offset -2 Setting using diagrams FIGHTER 310P is equipped with outdoor temperature HEATING CURVE KURVLUTNING controlled automatic controls. This means the flow °C temperature is regulated in relation to the current out- 15 14 13 12 door temperature.
  • Page 21: Dealing With Malfunctions

    (42). Contact the installer. If the operating disturbance cannot be rectified by means of the above an installation engineer should be called. If necessary set the switch to R” (manual shunt operation necessary). FIGHTER 310P...
  • Page 22: Indications On The Display

    Low pressure pressostat: Ventilation flow too low should always be stated with all or not enough refrigerant. correspondence with NIBE. When the cause of the fault has been put right, the 089_ _ _ _ _ _ _ _ _ _ _ fault code must be cleared from the display by switch- ing the heat pump off and on again..
  • Page 23: Resetting The Miniature Circuit Breakers

    It is usually easier to start the circulation pump with FIGHTER 310P running, switch (8) set to “1”. If help- ing the circulation pump to start is performed with FIGHTER 310P running, be prepared for the screw- driver to jerk when the pump starts.
  • Page 24: Service

    Work on the refrigerant system must be done by authorised personnel in accordance with the relevant legislation on refrigerants, supplemented by additional requirements for flammable gas, for example, product knowledge as well as service instruction on gas sys- tems with flammable gases. FIGHTER 310P...
  • Page 25: Component Locations

    Efterfyll värmesystemet vid behov. Ystad 11 (5) 55 56 Se skötselanvisning. Sypply line (70), Fram- ledning radiator circurit radiatorer Hot water (74), outlet v.v. Cold water (73), k.v. Return line (71), Åter- ledning from water heater connection radiator circurit radiatorer FIGHTER 310P...
  • Page 26: Electrical Circuit Diagram

    2,0 kW Vit 6,0 kW Brun Pos R Läge R Elektrisk matning Power supply for load för effektvakt (tillbehör) monitor (accessories) N N 3 Contactor marking Kontaktormärkning For all conntactors Gäller samtliga kontaktorer – 230 V 12 V FIGHTER 310P...
  • Page 27: List Of Components

    95 Overflow pipe, safety valve water heater 96 Overflow pipe, safety valve heating 97 Condensation water outlet, fan box 98 Overflow water discharge ..........PVC-pipe Ø 32 mm (outside diameter) 99 Collection funnel, waste water 103 Serial number sign FIGHTER 310P...
  • Page 28: Dimensions

    Undvik rördragning inom streckmarkerat expansion vessel. område för att underlätta service A, B and C: See "Connection" in "List of components". Pipes must not be run from the floor in the area indicated by dots. FIGHTER 310P...
  • Page 29: Technical Specifications

    47 – 62 °C *(47 – 57) Cut-out temperature immersion heater 50 – 65 °C *(50 – 60) Sound level in the boiler house 45 – 50 dBA * See the section “Electrical connection” “Blocking immersion heater operation” FIGHTER 310P...
  • Page 30 Upgrade kit immersion heater ES With temporary high current drain the load monitor Used to increase the immersion heater output from disables parts of FIGHTER 310P’s electrical output to max 9 kW to max 13.5 kW. protect the building’s main fuses.
  • Page 32 NIBE AB Box 14 Tel: +46 - (0)433 - 73 000 Järnvägsgatan 40 Fax: +46 - (0)433 - 73 190 SE-285 21 MARKARYD www.nibe.com SWEDEN...