Advertisement

Quick Links

JUSHA LCD Monitor
CP620G
User Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CP620G and is the answer not in the manual?

Questions and answers

Summary of Contents for JUSHA CP620G

  • Page 1 JUSHA LCD Monitor CP620G User Manual...
  • Page 2 Hanzhongmen Street, Nanjing City, Jiangsu Province, 210036 China Tel: 0086-25-83305050 Fax: 0086-25-58783273 Free Hotline: 400-820-0556 800-820-0556 Visit us at the website: en.jusha.com.cn © Nanjing Jusha Display Technology Co., Ltd. /All rights reserved /2021. 3060300362 REV: A0 Published by Nanjing Jusha Display Technology Co., Ltd.
  • Page 3: Table Of Contents

    Contents Contents Manual instructions ........................1 About this manual ......................1 Explanation of symbols ....................1 Safety information ......................2 Overview ........................... 7 Features ......................... 7 Packing list ........................7 Front view and display port ................... 9 Display installation ........................11 Connecting the cables and power ................
  • Page 5: Manual Instructions

    If you discover any errors, please call us, or email. n For any further questions about this manual, you are welcome to contact Nanjing Jusha Display Technology Co., Ltd. (hereinafter referred to as JUSHA). 1.2 Explanation of symbols This manual and product may use the symbols below.
  • Page 6: Safety Information

    2002/96/EC Waste disposal should comply with local regulations. Recommend to refer the User Manual Manufacturer information JUSHA trademark Product serial number Caution: Federal law restricts this device to sale by or on the order of Rx Only a licensed health care practitioner * The display will conform to corresponding certification standard only when the provided power supply is used.
  • Page 7 Manual instructions About the environment n The equipment should be packed with the original leather bag in the attachment when moving or carrying. n The equipment should be installed near an easily accessible outlet. n Place the device on a flat, solid and stable surface that can support the weight of at least 3 devices.
  • Page 8 Please contact JUSHA for technical support. n Repairing is limited to trained engineers. Do not try to repair or disassemble the product by yourself.
  • Page 9 Ø Plug the display and the device under interference into different power sockets. Intended use n CP620G Series professional LCD monitor is intended to be used in displaying and viewing digital images for diagnosis of X-ray or MRI, etc. by trained medical practitioners. The device is not specified for digital mammography system.
  • Page 10 Manual instructions to digital signal by a graphic card. The digital information is send to the screen, then, the screen displays the pictures. Mechanism of action n The principle of display digital images using medical monitor is the selection of graphic card and the screen, the graphic card and the screen will affect the quality of medical images.
  • Page 11: Overview

    With the advantage of high resolution, high brightness characteristics, and built-in DICOM standard LUT, CP620G can be used in a variety of medical imaging diagnostics and comparative analysis, such as: CR, DR, MRI, CT, PACS, etc.
  • Page 12 If there is any accessory damage or loss, please contact us. Please only use the original accessories supplied with the display. JUSHA is not responsible for any technical problems caused by using third-part accessories. Please keep the original package. If you need to transport the...
  • Page 13: Front View And Display Port

    Overview 2.3 Front view and display port Power Key Indicator HDMI USB Type C 1 USB Type C 2 The front of the display is full covered by a piece of glass. And there’s a status indicator on the left side. escription Item Logo...
  • Page 14 Overview Full function:video(DP alt mode) 、power delivery、USB data communication USB Type C 1 The functions of the two interfaces are exactly the same and can be blind inserted at will Need to be used with USB 3.2 gen2 or Thunderbolt 3 or higher protocol USB cable USB Type C 2 The name “USB Type C”is often referred to simply as...
  • Page 15: Display Installation

    Display installation 3. Display installation 3.1 Connecting the cables and power There are four method to connect the display and the laptop or mobile phone: Description Method 1)Requires the laptop USB- C interface to support USB 3.2 gen2 or Thunderbolt 3 or higher protocol.
  • Page 16 Display installation Choose any USB port to connect to the power adapter, and connect the HDMI interface of CP620 to the HDMI signal source 1)Support the screen display direction to automatically rotate with gravity sensor 2)HDMI signal maximum support 3000*2000@50Hz 1)Requires the laptop USB- C interface to support USB 3.2 gen2 or Thunderbolt 3 or...
  • Page 17: Adjusting The Screen Position

    Display installation indicator is lit up, it means that the display has been powered up. Warning: Please read the “6.3 Safety standard” section carefully before connecting the power supply. Otherwise, it may cause electric shock or display permanent damage. 3.2 Adjusting the screen position You can adjust the angle of the display screen, in order to get the most comfortable viewing angle.
  • Page 18: Multi-Screen Display Setting

    Warning: Contact a technician for the installation. JUSHA is not responsible for any damage to the product or harm to customers when the installation is done by the customer.
  • Page 19: Windows 7 Operating System Setting

    Display installation 5. Click [To expand Windows desktop to the monitor] item to expand Windows desktop to the selected monitor. 6. After the completion of the various Settings, and then identify the number of the screen representing. 7. For example, the monitor in 6MP single screen mode corresponds to the number 1 of the 6MP display in Windows XP.
  • Page 20: Windows 10 Operating System Setting

    Display installation In the [Screen resolution] control panel, you can: l Arrange the logical position of the two displays by dragging the display icons. l Browse the connected display devices at the [Display] pull-down menu. l Choose different multi-display mode in the [Multiple displays] pull- down menu.
  • Page 21 Display installation...
  • Page 22 Display installation In the [Display] control panel, you can: l Arrange the logical position of the two displays by dragging the display icons. l Select the display by left-click mouse on the display icon, and then the display settings could be changed at the [Resolution] and [Orientation] pull-down menu.
  • Page 23: Display Settings

    Display setting 4. Display settings 4.1 Start the display Connect the monitor power adapter and turn on the computer or mobile phone connected to the display. Make sure that a graphic card and graphic card driver has been installed correctly. The display will automatically turn on and recognize the video signal, then the status indicator will turn white.
  • Page 24: Menu Hierarchical Reminder Icon

    Quality Control Type-C HDMI Power Touch Key Area 4.4.1 Menu hierarchical reminder icon Corresponding prompt icons under different menu levels will change accordingly. The corresponding indication buttons for each menu level are as follows Menu level Key 1 Key 2 Key 3 Navigation menu Curve...
  • Page 25: Menu Content

    Display setting 4.4.2 Menu content CP620 Backlight Diagnosis Status-DICOM Window 1 Curve Diagnosis Status -CT/MR-JS Window 2 Curve Diagnosis Status -GAMMA2.2 Reading Room Ambient Caution CP620 Windows Mode Auto Window 1 Source Type-C 1 Window 2 Source Autorotation Type-C 2 Phone Mode HDMI Window 1 Resolution...
  • Page 26 Quality Control Navigation Level 1 Level 2 Level 3 instruction Short press the “q”/“p” key to change in real time with a step length of 1. Long press to speed up step Shortcut Backlight 0-100 adjustment. maximum brightness automatically limited when the power supply is insufficient Single screen mode:...
  • Page 27 Display setting cycle to prompt every selected time: “Caution! Ambient light exceeds the legal limit!” Single Screen Default Single Screen Windows **USB-C1 and USB-C2 cannot be Mode Dual Screen displayed at the same time Auto Window Type-C 1 Default Auto Source Type-C 2 HDMI...
  • Page 28 Quality Control Note: Please refer to the help documentation for more information. The menu options and specifications of this product are subject to change without notice.
  • Page 29: Quality Control

    The monitor CP620G has been adapted to the WEBQA 3.0.4 version. Support for subsequent WEBQA 4.0 versions will be upgrade without notice. l Calibration function DICOM calibration of each machine is completed before outing factory. In order to ensure the conformity of DICOM, it is recommended to use WEBQA for verification regular.
  • Page 30: Important Information

    Air pressure: 700hPa - 1060hPa Certification CCC, CE standards Note: The specifications of JUSHA products are subject to change without notice. 6.2 Environmental information All materials of this product are below the limit requirement in RoHS, without toxic or hazardous substances.
  • Page 31: Safety Standard

    Important information 6.3 Safety standard This device complies with GB4943.1-2011 Safety standard IEC60601-1:2012 EN60601-1:2013 Compliance disclaimer CCC, CE 6.4 Electromagnetic compatibility The product’s electromagnetic compatibility conforms to the following conditions: GB/T9254-2008 EMI Voltage/ GB17625.1-2012 Radiated IEC60601-1-2:2014 interference EN60601-1-2:2015 Guidance and Manufacturer’s Declaration Below cables information are provided for EMC reference.
  • Page 32 Maintenance EMI Compliance Table (Table 1) Table 1 - Emission Phenomenon Compliance Electromagnetic environment CISPR 11 RF emissions Home healthcare environment Group 1, Class B IEC 61000-3-2 Harmonic distortion Home healthcare environment Class D Voltage fluctuations IEC 61000-3-3 Home healthcare environment and flicker Compliance EMS Compliance Table (Table 2-5)
  • Page 33 Important information 5240 5500 5100-5800 Pulse modulation 217Hz, 9V/m 5785 Table 4 – Input a.c. power Port Immunity test levels Phenomenon Basic EMC standard Home healthcare environment Electrical fast ±2 kV IEC 61000-4-4 transients/burst 100kHz repetition frequency Surges IEC 61000-4-5 ±0.5 kV, ±1 kV Line-to-line 3V, 0.15MHz-80MHz...
  • Page 34: Maintenance

    Maintenance 7. Maintenance 7.1 Avoid screen over-heat Please use the monitor in the recommended environments, including appropriate temperature, humidity and air pressure. Turn off the monitor or lower its luminance if not in use, or it may cause over-heat damage. In addition, if the screen monitors the same image for a long time, it may over-heat and cause damage to some pixels.
  • Page 35: Avoid Shock And Vibration

    Maintenance Never spray or pour any liquid directly onto the surface of the screen or case. Some chemical cleanser may damage the screen and case of the monitor. We recommend you to use non-ammonia and non-alcohol based cleanser. We are not liable for damage resulting from ammonia or alcohol based cleanser.
  • Page 36: Cleaning And Disinfection

    JUSHA does not recommend the use of any ammonia or alcohol-based cleaners on the monitor screen or case. Some chemical cleaners have been reported to damage the screen and/or case of the monitor. JUSHA will not be liable for damage resulting from use of any ammonia or alcohol based cleaners 8.2 Disinfection...
  • Page 37: Declarations

    Therefore, please consult your seller whether he/she provides relevant maintenance service. JUSHA will neither take any responsibility nor authorize anyone to take any responsibility for product distribution and its use. Please read carefully the related documents, operation instruction and labels on package before you apply the product so that you can use and maintain the product properly.
  • Page 38: After Sale Service Declaration

    JUSHA keeps patents, copyright and its exclusive right and all information in this manual including JUSHA all designs and related materials. Anyone cannot plagiarize JUSHA design or copy its product to sell or use without the company’s explicit authority. 9.2 After sale service declaration The after-sale warranty is three years from the date of purchase, only if the product has been used with the recommended brightness.
  • Page 39: Declaration Of Conformity

    The user shall not maintain or repair products at a place other than the after- sale service point of Nanjing Jusha Display Technology Co., Ltd., the original equipment number shall not be modified or removed. In order to...

Table of Contents