Summary of Contents for JUSHA E240AG

  • Page 1 User Manual...
  • Page 2 Model E240AG C230A C230M E240A JUSHA-C230A JUSHA-C230M JUSHA-E240A JUSHA-E240AG Document Number:3060300195 Version: A/0 Nanjing Jusha Display Technology Co., Ltd. 8A, Block 1, Nanjing International Service Outsourcing Mansion, No.301 Hanzhongmen Street, Nanjing City, Jiangsu Province, 210036 China...
  • Page 3 Tel: 0086-25-83305050 Fax: 0086-25-58783273 Visit us at the website: www.jusha.com.cn © Nanjing Jusha Display Technology Co., Ltd. 2018. All rights reserved. Published by Nanjing Jusha Display Technology Co., Ltd.
  • Page 5: Table Of Contents

    4.4 Operate OSD menu......................... 4.4.1 Choose signal source....................4.4.2 Control description....................... 4.4.3 Functional specification....................5. Important information........................5.1 Technical specifications......................5.1.1 E240AG......................... 5.2 Safety standards........................5.3 Electromagnetic compatibility....................5.3.1 EMC information......................5.4 EMC Guidelines........................5.5 Performance specifications....................5.6 Calibration function........................
  • Page 6 Contents 11. Declarations..........................11.1 Legal notice........................... 11.2 After-sale service declaration....................11.3 Proprietary rights........................12. Contact information........................
  • Page 7: Manual Instructions

     For any further questions about this manual, you are welcome to contact Nanjing Jusha Display Technology Co., Ltd. 1.2 Explanation of symbols This manual and product use the symbols below.
  • Page 8 (WEEE) 2002/96/EC Waste disposal should comply with local regulations. Recommend to refer the User Manual Manufacturer information JUSHA trademark Product serial number Caution: Federal law restricts this device to sale by or on the Rx Only order of a licensed healthcare practitioner.
  • Page 9: Safety Information

    Manual instructions 1.3 Safety information Warning: Read all the important safety information before installing and operating your monitor. About the environment  The equipment should be installed near an easily accessible outlet.  Place the device on a flat, solid and stable surface that can support the weight of at least 3 devices.
  • Page 10 If the product gives off smoke or makes unusual noises, cut off the mains supply as soon as possible and pull out the plug from the socket. Please contact JUSHA for technical support.  Repairing is limited to trained engineers. Do not try to repair or disassemble the product by yourself.
  • Page 11: Intended Use

    Users should take practicable measures to reduce the radio interference. 1.4 Intended use  The E240AG LCD Monitor is intended to provide 2Dcolor video displays of images from surgical endoscopic/laparoscopic camera systems and other compatible medical imaging systems. The E240AG...
  • Page 12: Mechanism Of Action

    1.6 Mechanism of action  The principle of display digital images using medical display is the selection of the screen, the screen will affect the quality of medical images. Note: 1.C230A,C230M,E240A,JUSHA-C230A,JUSHA-C230M,JUSHA-E240A,J USHA-E240AG. The operation method and specifications is the same as E240AG.
  • Page 13: Overview

     Desiccant Note: 1. Please only use the original accessories supplied with the monitor. JUSHA is not responsible for any technical problems caused by using Third-party accessories. 2. Packing list is for reference only, different models need to match different packing list, Please refer to the packing list in the product box.
  • Page 14: Front View And Keypad

    Overview 2.2 Front view and keypad Front view Endoscopic surgery professional medical monitors have front keypads. They are shown as below. The front keypad Keypad description: Indicates the monitor operating status 1. Lights up in orange, indicates monitor in Power light power-on standby 2.
  • Page 15: The Backside View Of The Monitor

    Overview 2. Exit the User menu Increase the menu option value or go to the Right key next menu level Left key Decrease the value of the menu option 2.3 The backside view of the monitor: Backside of monitor Connectors: The connector configuration may depend on customer’s requirements.
  • Page 16 Overview BNC board interface definition Connectors’ description: DC power input ON/OFF VGA input DVI input SDI output SDI input DVI output 5V output Y/C input CVBS input 11 G/Y input B/PB input 13 R/PR input HS/CS input 15 Y/C output CVBS output 17 G/Y output B/PB output...
  • Page 17: Monitor Installation

    1.Plug one side of the signal wire into monitor’s back interface, and the other side into endoscopic host’s interface, then Tighten the screws. E240AG supports desktop and wall design. So it can be installed by wall hanging or bracket, which should withstand the force of 7kg at least.
  • Page 18: Installing The Display To Wall Or Suspension Arm

    Monitor installation Country/Area U.S.A./Canada EU (except U.K.) Plug Shape ANSI/UL 817 DIN VDE BS1363/BS546 Standard CSA-C22.2 No.21 0620-1:2010 Voltage 120V 230V 230V Country/Area Brazil Japan Korea Plug Shape NBR14136 JIS 8303 KSC8305:2002R Standard Voltage 220V 110V 220V Country/Area Denmark Singapore China Plug Shape SB 107-2-D1...
  • Page 19 • The monitor and arm or stand are heavy. Dropping them may result in injury or equipment damage. Warning: Contact a technician for the installation. JUSHA is not responsible for any damages to the product or harm to customers when the installation is done by the customer.
  • Page 20: Monitor Settings

    Turn the power on, the power indicator will turn orange, press the power button on the front of the monitor, then the power indicator will turn white, and the monitor's screen will display the JUSHA boot screen, indicating that the monitor is running.
  • Page 21: Operate Osd Menu

    Monitor settings monitor, which allows users to adjust monitor’s parameters by using the On Screen Display (OSD) system. 4.4 Operate OSD menu 4.4.1 Choose signal source To display the standard input menu, please press the “ ” button once to open the signal source selection menu. Signal source selection menu 4.4.2 Control description 1) In the user menu, press...
  • Page 22: Functional Specification

    Monitor settings DVI-D ● ● ● ● ● ● ○ ○ ● ● ● ● ● ● ○ ○ Table 1 The selection rule of main source and sub source in Multi-window function 4.4.3 Functional specification 1) Press the “MENU” key once to open the user menu: User Menu 2) The structure of user menu and functional specification: Item...
  • Page 23 Monitor settings User1 Mode, in this mode, the first user ’s Mode1 preference parameters(such as brightness, sharpness) shall be stored. User2 Mode, in this mode, the second user ’s Mode2 preference parameters(such as brightness, sharpness) shall be stored. User3 Mode, in this mode, the third user ’s Mode3 preference parameters(such as brightness, sharpness) shall be stored.
  • Page 24 Monitor settings Scale up 15% Scale up 20% Gamma 2.0’s effective Gamma Gamma 2.2’s effective Curve DICOM DICOM effective Auto adjustment for analog source only(VGA, Auto no item no item RGBS) Backlight 0--100 Brightness 0--100 Setting Contrast 0--100 Saturation 0--100 0--100 5500K 5500K color temperature effective...
  • Page 25 Monitor settings Open the picture out picture mode2, picture POP2 in main and sun window shall be displayed in max ratio according to input source The sub source shall be determined by the main source, please refer to Table 1 to find Sub Source CVBS the selection rule of main source and sub...
  • Page 26: Important Information

    Maintenance 5.Important information 5.1 Technical specifications 5.1.1 E240AG Input voltage DC 24V Standby power <0.5W consumption Consumption(nominal) LCD Panel 23.8 inch,mono-TFT Liquid Crystal Display Viewing angle Horizontal 178°,Vertical 178° (CR ≥ 20) Pixels distance 0.27mm(H)mmx 0.27(V)mm Resolution 1920 x 1080...
  • Page 27: Safety Standards

    Maintenance transportation and storage Air pressure: 200hPa~1060hPa Certification standards CCC CE Note: The specifications of JUSHA products are subject to change without notice. 5.2 Safety standards Safety standards for E240AG Safety Standards for IEC 60601-1: 2012,EN 60601-1:2013 the Medical Display GB4943.1-2011...
  • Page 28: Emc Guidelines

    If the product gives off smoke or makes unusual noises, cut off the mains supply as soon as possible and pull out the plug from the socket. Please contact JUSHA for technical support.  Repairing is limited to trained engineers. Do not try to repair or disassemble the product by yourself.
  • Page 29  The use of accessories and cables other than those specified by NANJING JUSHA DISPLAY TECHNOLOGY CO., LTD., with the exception of accessories and cables sold by NANJING JUSHA DISPLAY TECHNOLOGY CO., LTD. of LCD MEDICAL DISPLAY...
  • Page 30 Maintenance protection to radio-frequency communication services. The user might need to take mitigation measures, such as relocating or re-orienting the equipment. Table 2 - Enclosure Port Immunity test levels Basic EMC Phenomenon Professional healthcare facility standard environment Electrostatic IEC 61000-4-2 ±8 kV contact Discharge ±2kV, ±4kV, ±8kV, ±15kV air...
  • Page 31 Maintenance 5240 5500 5100-5800 Pulse modulation 217Hz, 9V/m 5785 Table 4 – Input a.c. power Port Immunity test levels Basic EMC Phenomenon Professional healthcare facility standard environment Electrical fast ±2 kV IEC 61000-4-4 transients/burst 100kHz repetition frequency Surges IEC 61000-4-5 ±0.5 kV, ±1 kV Line-to-line Surges...
  • Page 32: Performance Specifications

    5.6 Calibration function 5.6.1 Automatic luminance calibration JUSHA medical display has Auto Luminance calibration function, the luminance level can be stabilize at the value which the user set. This function is performed by medical display when working , No user action...
  • Page 33: Dicom And Gamma Calibration

    (4) Click on the calibration button (5) report is generated after the end of the calibration 5.6.3 Color calibration E240AG calibrate color refer to EBU standard. (1) display the test image on E240AG. (2) measure the chromaticity coordinate of the image using color analyzer.
  • Page 34: Maintain The Proper Humidity

    Maintenance lower its luminance if not use, or it may cause over-heat damage. In addition, if the screen displays the same image for a long time, it may over-heat and cause damage to some pixels. 6.2 Maintain the proper humidity The display can work properly at the humidity between 20% and 85%.
  • Page 35: Do Not Disassemble The Display

    Maintenance 6.5 Do not disassemble the display Never try to disassemble the display or remove/change its LCD panel. Unauthorized repair and refit will result in temporary or permanent display failure. Warning: Please do not touch the metal part of power plug to avoid electric shock. Please keep the power socket and 5V DC away from water.
  • Page 36: Cleaning And Disinfection

    JUSHA does not recommend the use of any ammonia or alcohol-based cleaners on the monitor screen or case. Some chemical cleaners have been reported to damage the screen and/or case of the monitor. JUSHA will not be liable for damage resulting from use of any ammonia or alcohol based cleaners 7.2 Disinfection...
  • Page 37: Hardware/Software Compatibility Requirements

    Cleaning and Disinfection 8.Hardware/software compatibility requirements 8.1 Available signal format E240AG LCD Monitor supports several input video signal, that includes analog signal format and digital signal format. Analog signal format Input interface S_VIDEO RGBS YPBPR CVBS signal format NTSC √...
  • Page 38 Cleaning and Disinfection 1080/25p √ √ 1080/24p √ √ 1080/23p √ √...
  • Page 39: Malfunction Analysis

    Please contact us if failed to resolve problem after reading the recommended solutions followed. To solve the problem, please contact Nanjing Jusha display technology co., Ltd after-sales service or read the manual to find proper solutions. If you use the recommend below solution still can't solve the problem, please contact Nanjing jusha display technology co., Ltd.
  • Page 40 Malfunction analysis 1. Connection problem of power wire or signal wire Snowflake on screen 2. Main board static electricity or dust affection the connection of graphic card. 1. Connection problem of power wire or signal wire No figure after displaying well for a while 2.
  • Page 41: Declaration Of Conformity

    Declarations 10. Declaration of Conformity This machine could meet the following two conditions  This machine will not generate Dangerous interference  This machine will not come into unpredictable results...
  • Page 42: Declarations

    Declarations 11. Declarations 11.1 Legal notice The auxiliary equipment that is connected with JUSHA display should meet the corresponding IEC Standard (data processing equipment should meet IEC 60950-1 Standard and armamentariums should meet IEC60601-1 Standard). In addition, all configurations should meet IEC 60601- 1: 2005 + CORR.
  • Page 43: After-Sale Service Declaration

    ,rules, commercial practice, conventions or trade disputes etc. In no event shall JUSHA and its suppliers/franchisers be liable for any special, incidental, punitive, indirect or consequential damages (including, but not limited to, delay deliver, non-delivery, fault items,...
  • Page 44: Proprietary Rights

    SERVICE PERSONEL in parts repair. 11.3 Proprietary rights Nanjing Jusha Display Technology Co., Ltd keeps the copyright of this manual and other related ownership. It is not allowed to copy, use or sell this manual without authorization of Nanjing Jusha Display Technology...
  • Page 45: Contact Information

    Contact information 12. Contact information Nanjing Jusha Display Technology Co., Ltd. Address: 8A, Block 1, Nanjing International Service Outsourcing Mansion, No.301 Hanzhongmen Street, Nanjing City, Jiangsu Province, 210036 China Tel: 0086-25-83305050 Fax: 0086-25-58783273 Web: www.jusha.com.cn...

This manual is also suitable for:

C230aC230mE240aJusha-e240ag