If you discover any errors, please call us, or email. For any further questions about this manual, you are welcome to contact Nanjing Jusha Display Technology Co., Ltd. (hereinafter referred to as JUSHA). 1.2 Explanation of symbols This manual and product may use the symbols below.
Page 6
Indicates the product meets the requirements of CE Certification. European Authorized Representatives Gives information of the Authorized European representatives. Waste Electrical and Electronic Equipment Directive (WEEE) 2002/96/EC Waste disposal should comply with local regulations. Recommend to refer the User Manual Manufacturer information JUSHA trademark Product serial number...
Manual instructions 1.3 Safety information Warning: Read all the important safety information before installing and operating your display. About the environment The equipment should be installed near an easily accessible outlet. Place the device on a flat, solid and stable surface that can support Weight of at least 3 devices.
Page 8
If the product gives off smoke or makes unusual noises, cut off the mains supply as soon as possible and pull out the plug from the socket. Please contact JUSHA for technical support. Repairing is limited to trained engineers. Do not try to repair or disassemble the product by yourself.
Page 9
Manual instructions The operator should not touch the video interface (such as DVI port, VGA port and etc.), or it may result in potential ESD (Electrostatic Discharge) damage to the display. The backlight of LCD has a service life limitation. We strongly suggest that this display is used in the recommended brightness to extend its service life.
DICOM standard LUT, M550,M550G can be used in a variety of medical imaging diagnostics and comparative analysis, such as: CR, DR, MRI, CT, PACS, etc, and is especially suitable for mammography. Note: M550G,M550,JUSHA-M550G,JUSHA-M550,M55***,JUSHA-M55*** Where “*” represents the suffix. The suffix indicate different marketing regions.
Page 11
Brightness immediately arise (BIA) technology Normally, it takes about 30 minutes for the traditional displays to reach the required luminance and remain stable. JUSHA develops the BIA technology, which shortens the waiting time to 30s with the innovation in luminance driver program.
2. If there is any accessory damage or loss, please contact us. 3. Please only use the original accessories supplied with the display. JUSHA is not responsible for any technical problems caused by using third-part accessories. Please keep the original package. If you need to transport the...
Overview 2.3 Front view and keypad The keys except power key are silkscreen keys. Touch any key except power key to bring up the navigation key icons, as shown below. Then if touch the key below , the navigation key icons change, as shown below.
Page 14
Overview Keypad functions: Key Define Key Icon Function 1. Steady white, the display works normally 2. Slow blinking white, no signal. 3. Steady orange , the display works Power LED abnormally and bring up an OSD alert 4. Dimmed, the display is off Power key To enter sleep mode Exit key...
Overview 2.4 Rear view and connection panel Power switch DVI-D Dual Link video input Power input DP (DisplayPort) video input USB1(USB upstream connector) DP(DisplayPort) video output USB2(USB downstream connector) Note: USB2 can be connected to a mouse or keyboard when USB1 is connected to the host.
Display installation 3. Display installation 3.1 Graphic card installation Note: Before start to install the graphic card, please make sure the computer motherboard supports the PCI Express graphic card and has an empty PCI Express x1 Slot. Carefully read the manual of the motherboard about how to install an expansion card.
Display installation 3.2 Connecting the cables Use the DVI or DP video cables to connect the monitor to the computer host graphic card. The display will automatically complete the selection of video input signal. 1. Through the video cables, put the video interface on the graphics, such as DVI, DP, etc., connect to the corresponding video interface on the display.
Display installation 3.3 Adjusting the screen position You can adjust the height and angle of the display screen, in order to get the most comfortable viewing angle. 3.3.1 Adjusting screen height To move the screen up and down, please hold the screen at both sides and adjust it to an appropriate height.
Display installation swivel angle. Note: The allowed tilt angle range for this display is from 0° (±2°) to + 20° (±2°). The swivel angle range is from -45°(±4°) to + 45°(±4°). 3.3.3 Rotating screen 1. Please remove all connections of the display at first. 2.
Warning: Contact a technician for the installation. JUSHA is not responsible for any damage to the product or harm to customers when the installation is done by the customer.
Display installation 3.5 Multi-display configuration Windows OS provides the multi-display feature to allow applications to make use of multiple display devices at the same time. This is useful whenever you need to maximize your onscreen workspace. For example, there are two displays used at the same time: one is used to view the medical images for diagnosis, while the other is used to browse the patient medical history.
Display installation 3.5.2 For Microsoft Windows 7 operation system 1. The DVI or DP interface on the graphic card is connected to the display corresponding DVI or DP interface by using video cables. (Please see “3.2 connecting the cables” section). 2.
Display settings 4. Display settings 4.1 First time starting up 1. Open a computer connected to your monitor. Make sure that a display and a graphic card and graphic card driver has been installed correctly. 2. Turn on the power switch, and then touch the power key approximately 1 second, all the key lights are lit up at the same time.
Display settings 4.3 OSD overview User can change display settings by keypad and OSD (On Screen Display) menu to meet the needs of the working environment. Similarly, the user can also view the basic information and the current settings of the display by using OSD menu.
Page 25
Display settings The following table shows the structure and parameters of the OSD menu in English. Main Menu Submenu Parameter Specification Default Settings Backlight 0-100 DICOM CT/MRI Gamma2.2 Curve DICOM Gamma2.4 Close Auto Diagnostic Reading Room CT/MR/NM Close Office Viewing Input Source Circle Spotlight Type...
Display settings 4.4 OSD operation 4.4.1 Open OSD Bringing up the OSD menu can be done by: 1. In the state of that the display is turned on, touch any key except power key to bring up the navigation key icon. 2.
Display settings Note: LED backlight has a certain lifetime. Recommend to use the brightness of the factory default values to optimize the lifetime of your display. 4.4.4 Change Curve There are six calibration curves built in the display, and the user can choose any one curve as desired.
Display settings touch the key to confirm. Note: Reading Room can only be enabled on your display when the DICOM display function is selected. 4.4.6 Ambient Brightness Adaptation The display has Ambient Brightness Adaptation (ABA) function to be chosen as desired. The operation is as follows: 1.
Display settings item, and then touch the key to enter the "Input Source" item. 5. Touch the key to choose <DVI> or <DP> as demand and touch the key to confirm. 4.4.8 Spotlight Type The display has two different spotlight type to be chosen as desired. The operation is as follows: Touch any key except power key to bring up the navigation key icon.
Display settings The operation is as follows: Touch any key except power key to bring up the navigation key icon. Touch the menu key to bring up the OSD main menu. By default, the OSD cursor is in the main menu. Touch the key to move the cursor to the , then touch...
Display settings and then touch the menu key to enter the "Language" item. 5. Touch the key to choose Chinese or English language and touch the key to confirm. 4.4.13 Factory Reset Before delivery, the display has a default and recommended factory settings.
Display settings 4.5.1 SmarTouch Touch any key except power key to bring up the navigation key icon. Then touch the key to turn on or off the function of the SmarTouch. Note: The function of the SmarTouch and Ambient brightness cannot be used at the same time.
Page 33
Spotlight function requires the independent software to support. Therefore, please refer to the dedicated user guide about installing and using JUSHA CGA software on the documentation CD. The function of the Spotlight and Ambient brightness cannot be used at the same time. When open the function of the Spotlight, the function of the ambient brightness will automatically be closed.
Humidity: 5% - 85%(No condensation) storage Environment Air pressure: 200hPa ~ 1060hPa Certification standards CCC,CE Note: The specifications of JUSHA products are subject to change without notice. 5.2 Environmental information All materials of this product are below the limit requirement in RoHS,...
Important information without toxic or hazardous substances. 5.3 Safety standard This device complies with IEC 60601- 1: 2012 Safety standard EN 60601-1:2013 GB4943.1-2011 Compliance disclaimer CCC、CE 5.4 Electromagnetic compatibility 5.4.1 EMC information Warning: Display requires special precautions regarding EMC and need to be installed, put into service and used according to the following information.
Page 36
JUSHA DISPLAY TECHNOLOGY CO., LTD., with the exception of accessories and cables sold by NANJING JUSHA DISPLAY TECHNOLOGY CO., LTD. of LCD MEDICAL DISPLAY as replacement parts for internal components, may result in increased EMISSIONS or decreased IMMUNITY of the LCD MEDICAL DISPLAY.
Page 37
Important information EMI Compliance Table Table 1 - Emission Phenomenon Compliance Electromagnetic environment CISPR 11 RF emissions Professional healthcare facility environment Group 1, Class B Harmonic IEC 61000-3-2 Professional healthcare facility environment distortion Class A Voltage IEC 61000-3-3 fluctuations Professional healthcare facility environment Compliance and flicker EMS Compliance Table...
Important information 2450 2400-2570 Pulse modulation 217Hz, 28V/m 5240 5500 5100-5800 Pulse modulation 217Hz, 9V/m 5785 Table 4 – Input a.c. power Port Immunity test levels Basic Phenomenon Professional healthcare facility standard environment Electrical fast ±2 kV IEC 61000-4-4 transients/burst 100kHz repetition frequency Surges IEC 61000-4-5...
Maintenance 6. Maintenance 1. Avoid screen over-heat Please use the display in the recommended environment, including appropriate temperature, humidity and air pressure. Turn off the display or lower its luminance if not use, or it may cause over-heat damage. In addition, if the screen displays the same image for a long time, it may over-heat and cause damage to some pixels.
Page 40
Maintenance Some chemical cleanser may damage the screen and case of the display. We recommend you to use non-ammonia and non-alcohol based cleanser. We are not liable for damage resulting from ammonia or alcohol based cleanser. 4. Avoid shock and vibration The LCD screen is quite fragile, so avoid strong shock and vibration.
JUSHA does not recommend the use of any ammonia or alcohol-based cleaners on the monitor screen or case. Some chemical cleaners have been reported to damage the screen and/or case of the monitor. JUSHA will not be liable for damage resulting from use of any ammonia or alcohol based cleaners 7.2 Disinfection...
Please contact us if failed to resolve problem after reading the recommended solutions followed. To solve the problem, please contact Nanjing Jusha display technology co., Ltd after-sales service or read the manual to find proper solutions. If you use the recommend below solution still can't solve the problem, please contact Nanjing Jusha display technology co., Ltd.
1. Connection problem of power wire or signal wire No figure after displaying well for a while 2. Main board static electricity or dust affection the connection of graphic card. 9. Declarations 9.1 Legal notice The auxiliary equipment that is connected with JUSHA display should...
Page 44
JUSHA hereby explicitly rejects all warranties and state of any kind, any property or extent whether statutory, express or it leads to any laws ,rules, commercial practice, conventions or trade disputes etc.
JUSHA keeps patents, copyright and its exclusive right and all information in this manual including JUSHA all designs and related materials. Anyone cannot plagiarize JUSHA design or copy its product to sell or use without the company’s explicit authority. 9.2 After sale service declaration The after-sale warranty is three years from the date of purchase, only if the product has been used with the recommended brightness.
Quality assurance is only for the product that Nanjing Jusha Display Technology Co., Ltd provides. Any other third-party equipment problems are beyond the scope of this quality assurance.
Need help?
Do you have a question about the M550 and is the answer not in the manual?
Questions and answers