Operating Manual STW84V
For more information and help about this product please scan the
choose the following link:
Operating manual, Quick guide, Datasheet, Connection diagram, CAD Data
Firmwareupdates, FAQ, Videos about installation and settings, Certificates
- Control for suction plants
STW84V
11250-0707-02
Mains Monitoring
Digital Panelmeters MINIPAN®
STW84V
Switching Relays and Controls
Page 1 / 14
ZIEHL industrie – elektronik GmbH + Co KG
Daimlerstr.13, 74523 Schwäbisch Hall, Germany
+ 49 791 504-0,
info@ziehl.de,
Measuring Transducers
Grid- and Plant Protection
updated: 2024-04-18 /Sc
from Firmware: 43-06
QR-Code
or
www.ziehl.de
www.ziehl.de

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the STW84V and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for ZIEHL STW84V

  • Page 1 ZIEHL industrie – elektronik GmbH + Co KG Daimlerstr.13, 74523 Schwäbisch Hall, Germany + 49 791 504-0, info@ziehl.de, www.ziehl.de Temperature Relays and MINIKA® Mains Monitoring Digital Panelmeters MINIPAN® Switching Relays and Controls Measuring Transducers Grid- and Plant Protection updated: 2024-04-18 /Sc...
  • Page 2: Table Of Contents

    Deviations from the following requirements may therefore lead both to the loss of the statutory material defect liability rights and to the liability of the buyer for the product that has become unsafe due to the deviation from the specifications. STW84V 11250-0707-02 Page 2 / 14...
  • Page 3: Display And Operating Elements

    7) Button for selecting the channel 3 Application and short description The current relay STW84V monitors up to 8 alternating current sets on current flow yes/no. The inputs can analyse signals of current transformers type STWA1(H) or of potential-free contacts.
  • Page 4: Overview Of Functions

    K1...K8: 0... 99 s • operating value I1...I8: app. 0.5... 5 A • volume-flow of slide-valves 1...100 % Combination of more STW84V: Master-relay considers volume-flow of other relays for: • control of suction-fan (relay K9 and analog output 0-10 V) •...
  • Page 5: Connection Plan

    For primary currents > 16 A, this voltage can be dangerous for human beings. An "open mode", i.e. operation of the current transformer without secondary wiring, should be avoided. STW84V 11250-0707-02 Page 5 / 14 www.ziehl.de...
  • Page 6: Installation

    The polarity of the STWA1 current transformer output (white marking on the cable) must be observed only if several current transformers are connected in series to increase the sensitivity. Attention! Only one current-carrying conductor may be routed through the transformer! STW84V 11250-0707-02 Page 6 / 14 www.ziehl.de...
  • Page 7: Detailed Description

    0 ... 100 % MS: 100 % When the input 0,5 … 10 V of a STW84V is connected to the output it is recommended to use the manufacturers setting (MS) for the output. • I4 is ON: Function dedusting input Y2 0/1...100 % MS: 0%...
  • Page 8: Selection And Programming Of Other Modes Of K10 / K11

    Set the value in consideration of the cross section of the slide-valve and the suction duct and the suction resistance of the machine. When 2 or more STW84V are combined it is recommended to set the proportional value of the whole system for the slide-valve.
  • Page 9: Dedusting/Cleaning (Reinigung K11) Mode 0

    When button "▼ " is pushed during operation, the remaining time until the next dedusting is displayed. The value (minutes) has to be multiplied with the factor M (set under I8) and refers to 100% of volume- flow for the remaining time. STW84V 11250-0707-02 Page 9 / 14...
  • Page 10: K10/K11 Mode 1, For K10 Or K11. Control Of Discharge

    Attention ! This will reset all parameters to manufacturers settings (MS). Only mode of K10 and K11 and the function of the input Y2 are not affected! If the error still remains send back to factory for repair. STW84V 11250-0707-02 Page 10 / 14...
  • Page 11: Technical Data

    Inputs, Sensor connections I1, I2, I3, I4, I5, I6, I7 und I8 Connectable sensors - current transformer STWA1(H) - potential-free contact - ZIEHL Current-Sensor S1 ca. 15 kΩ Internal resistance of inputs current overload capacity with STWA1(H) max. 100 A continuously, max.
  • Page 12: Design V8

    12 Disposal Disposal should be carried out properly and in an environmentally friendly manner in accordance with legal provisions. ZIEHL is registered with the EAR Foundation under WEEE no .: DE 49 698 543. STW84V 11250-0707-02 Page 12 / 14...
  • Page 13: Overview Of Settings And Quick Guide

    ** Mode 0: K10 picks up when addition time is reached and remains picked up until the programmed time after dedusting has been accomplished. Mode 1: K10/K11 picks up as soon as a valve is opened and remains picked up until the programmed time after K9 has been switched off or after dedusting has been accomplish STW84V 11250-0707-02 Page 13 / 14...
  • Page 14: Setting Values

    • ** Mode 1: K10/K11 picks up as soon as a valve is opened and remains picked up until the programmed time after K9 has been switched off or after dedusting has been accomplish STW84V 11250-0707-02 Page 14 / 14...