2 X2 WAVEFLAME / WAVEFLAME HEAD AND LPS
2.1 STORAGE
Depressurize the System of every effect device after every show and again before moving them
into storage to avoid wearing out sealing- and moving parts!
Clean the effect devices with rubbing alcohol to get rid of unburned fuel and dirt or grime!
Use a toothbrush or scour pads to clean the electrodes!
Store the X2 Wave Flames / LPS with at least 1Liter of fuel in the tank to avoid damages when
pumping up the device and having forgotten to add more fuel!
Run the system at least once a month to ensure proper lubrication and avoid drying out of the
pump system!
When running the system, if possible, shoot the devices to ensure proper
2.2 BEFORE EVERY SHOW
Check safety distances and adjust accordingly!
When changing nozzles, only fasten them hand tight!
Prepare a CO2 Extinguisher just in case!
Check the devices by firing them with the chosen controller for the upcoming show!
Check if enough liquid is in the tank and prepare more canisters to fast swap if necessary!
2.2.1 FOR DMX:
Avoid DMX cables and Power cables running alongside each other.
Always use DMX terminators on the last device in a DMX chain.
2.2.2 FOR RC:
Check connection of transmitter and receivers on location!
Check if the show has been transmitted to all receivers!
2.3 AFTER EVERY SHOW
Check devices for damages and mark faulty ones with tape and a description of the issue!
Depressurize the system by disarming the devices!
Clean the devices when they are dirty!
function!
3
Need help?
Do you have a question about the X2-Wave-Flame and is the answer not in the manual?