Page 2
READ THE ENTIRE OPERATING MANUAL PRIOR TO INSTALLATION AND USE. +1 (714) 893 - 8529 sales@blue-white.com customerservice@blue-white.com 5300 Business Drive Huntington Beach, CA 92649...
Table of Contents 1.0 Introduction 1.1 What’s in the box 1.2 Features 1.3 Application Notes 1.4 Ordering Information / Product Matrix 2.0 Engineering Specifications 2.1 Flow Meter Specifications 2.2 Materials of Construction 2.3 Flow vs. Pressure Graph 2.4 Flow Specifications 2.5 Dimensions 3.0 Installation 3.1 Installation Requirements...
Page 4
SAFETY INFORMATION Please read this manual completely before unpacking, installing, and operating this equipment. In particular, pay attention to all dangers, warnings, and precau- tions, otherwise, it may cause serious injury to the operator or damage to the equipment. Note: When in doubt regarding your electrical installation, contact a licensed electrician.
• Upward flow, vertical installation only 1.3 Application Notes Although meters may be suitable for other chemicals, Blue-White cannot guarantee their suitability. It is the responsibility of the user to determine the suitability of the flow meter in their application. Flow meters are tested and...
P.N. 83000-040 F-452 REV 8 20231211 Scale Length 8” (200mm) 5300 Business Drive, Huntington Beach, CA 92649 TEL 714-893-8529 | FAX 714-894-9492 | www.blue-white.com | sales@blue-white.com Environment Not for direct sunlight exposure Maximum Pressure Drop 2 PSI Approximate Shipping Weight...
F-452 2.2 Materials of Construction Wetted Components: Non-wetted Components: Meter Body Union Nuts Polysulfone Fiber reinforced nylon Adapters Polysulfone Guide Rod Holder Polysulfone O-ring Seals Viton (optional EP) ® Float 316SS or PTFE (varies per model) Guide Rod 316SS Optional Shield Polycarbonate 2.3 Temperature vs.
F-452 2.5 Dimensions Inch 18-7/8” 47.9 4-5/8” 11.7 3.0 Installation 3.1 Installation Requirements Before beginning installation, review your system flow and pressure to ensure your F-452 is proper for your system parameters. Pipe Requirements: • The flow meter is designed to work best when installed in a perfectly vertical pipe system. •...
F-452 Always wear protective clothing, face shield, safety glasses and gloves when working on your equipment. Use caution when lifting and mounting equipment. When in doubt, contact factory for assistance. 3.3 Installation Instructions 1. The flow meter must be installed in a vertical plane to ensure accuracy.
F-452 3.3 Polycarbonate Shield Installation Instructions Use these instructions if you have purchased the optional Polycarbonate Shield Kit, KIT-SHL. 1. Unpack the KIT-SHL. The kit includes shield and two new grooved union nuts. En- sure all components are present and in good shape.
F-452 4.0 Reading your F-451 Flow Meter Avoid imposing a sudden burst of flow to the meter. Solenoid valves may cause the float to impact the top float stop with destructive force. Always read float at top. 5.0 Maintenance and Troubleshooting •...
F-452 F-452 F-452 6.0 Spare Parts EXPLODED VIEW, PARTS L ATION GUIDE meter must be installed in a EXPLODED VIEW ane to ensure accuracy. Qty. t may damage the flowmeter Item Model No. Product Name Req. y cause the o-ring seals to leak. F-452004N Union Nut (Nylon) PTFE tape on the threaded...
Blue-White is pleased to assist in this effort but does not guarantee the suitability of any particular product for any specific application as Blue-White does not have the same degree of familiarity with the application that the customer/end user has.
Page 16
P.N. 80000-258 F-452 Flow Meter REV 4 20240605 5300 Business Drive, Huntington Beach, CA 92649 TEL 714-893-8529 | FAX 714-894-9492 | www.blue-white.com | sales@blue-white.com...
Need help?
Do you have a question about the F-452 Series and is the answer not in the manual?
Questions and answers