Summary of Contents for DELTA DORE TYMOOV Solar 5 SO
Page 1
TYMOOV Solar 5 SO / 10 SO / 15 SO / 20 SO Range of solar-powered wireless tubular motors...
Page 2
Recommendations These instructions are intended for professional fitters or electricians performing the installation, maintenance, or disassembly of the roller shutter. WARNING: Important safety instructions Incorrect installation can result in serious injuries. Follow all instructions and retain these installation instructions for future reference.
Page 3
- TYMOOV xSO motors are motors with 868 MHz - X3D wireless receivers. They are only compatible with remote controls from the DELTA DORE X3D range: TYXIA 1701, TYXIA 2331 and TYXIA 1716. - Sufficiently rigid roller shutter slats should be used.
Page 4
- It is essential that you connect the TYMOOV Solar motor to the DELTA DORE solar panel and the DELTA DORE battery. Using another panel can cause functional faults. - TYMOOV xSO motors check the physical stops every 100 operations, so the motor automatically compensates for any apron movement.
Page 5
France France Par la présente, DELTA DORE déclare sous sa seule responsabilité que le produit ci-dessus est en conformité avec la Par la présente, DELTA DORE déclare sous sa seule responsabilité que le produit ci-dessus est en conformité avec la législation d'harmonisation de l'Union Européenne :...
Contents 1/ Technical Specifications ..............7 2/ Motor fitting ..................8 2.1 Crown and wheel assembly ..............8 2.2 Assembly in the tube ................8 2.3 Motor head position ................9 2.4 Mounting of the motor onto its support ..........9 3/ Connection ..................10 4/ Starting up for the first time ............10 4.1 Disabling transport mode ..............
1/ Technical Specifications • Power supply: 12 Vcc TYMOOV solar motors may only be used with the DELTA DORE batteries supplied with the motors: TYMOOV 5 SO: Battery 10S1P 1200 Ni-MH ref. 7011725 (x5), 7011738 (x20) TYMOOV 10 SO - 15 SO: Battery 10S1P1 2200 Ni-MH ref. 6357037 (x1), 7011724 (x5) and 7011737 (x20) TYMOOV 20 SO: 2x Battery 10S1P1 2200 Ni-MH ref.
2/ Motor fitting • Never strike the motor head or output shaft to fit the motor into the tube. Never pierce the tube when the motor is installed. • To attach the apron, use screws that do not enter the tube by more than 1 mm. 2.1 Crown and wheel assembly Crown “Click”...
2.3 Motor head position The motor head should be positioned on the bracket so that the cable outlet is at the bottom in relation to the horizontal. 8 NO 8 NO 8 NO RJ11/RJ11 4 OK 4 OK 4 OK 2.4 Mounting of the motor onto its support Push the tube/motor assembly (A) onto the support (B) until it clicks.
3/ Connection Recommendations: When installing and mounting the panels and battery, ensure that the cables are running in the right direction and that they are positioned close to the motor head. The motor is supplied with a H05VVF power cable. This cable cannot be placed outdoors unless it and the connector are inside a UV-resistant conduit.
4/ Starting up for the first time 4.2 Pairing an initial remote control with a motor When switched on for the first time, the motor runs a cycle to warn that no transmitter is associated. The motors will automatically await association. You have 5 minutes after power up to associate the motor to the control device.
4/ Starting up for the first time 4.3 Stop settings You can use Auto mode if there are both upper and lower physical stops. The motor will automatically detect its end of travel distances. If there are no upper physical stops and/or automatic locks, you must set the end of travel manually.
Page 13
4.3.1 Storing 2 automatic stops ❶ Automatic upper stop Upper physical stop Stop on shutter slat Lower physical stop Press and release the button until the shutter locks against the upper stop. The stop position is stored automatically. The motor activates once. ❷...
Page 14
4/ Starting up for the first time 4.3.2 Store 1 manual stop + 1 automatic stop ❶ Position the shutter Progress stepwise Press the button to move the shutter to the To progress stepwise, briefly press the desired position, then press to stop it (*).
Page 15
4.3.3 Store 2 manual stops ❶ Position the shutter Progress stepwise Press the button to move the shutter to the To progress stepwise, briefly press the required position, then press to stop it (*). buttons at the same time, then release.
5/ Modifying stops The stops must first be removed then recorded again for them to be modified. Remove them by proceeding as follows : > 3s Press briefly on button B located On the transmitter, press together The motor briefly on the front panel of the remote and hold down the and buttons starts twice.
7/ Linking a smoke detector directly to the motor You want to control the opening of roller shutters if smoke is detected. > 3s On the already paired transmitter, press the button for more than 3 seconds, until the motor activates briefly. Press for 3 seconds the detector button.
8/ Obstacle detection The motors of the TYMOOV range include the obstacle detection feature. This fully protects the roller shutter mechanism. After locking on an obstacle, the motor reverses direction by about 15 cm. Obstacles can only be detected when the stops have been recorded. 8.1 Setting the type of obstacle detection You can choose between two detection modes : - Protect+ detection : (default mode), more efficient obstacle detection, preventing...
9/ Erasing one or more pairings 9.1 Erasing the pairing of the remote control with the motor - Remove the front panel of the remote control. - Press button A (or button T1 for the TYXIA 2331 wall-mounted remote control). The red LED flashes. - Press as many times as required to select the motor to remove.
11/ Pairing with an alarm control unit The pairing of the motor with an alarm control unit enables : - the anti-intrusion function attempt to raise the shutter), - the surveillance stop/start report. 11.1 Pairing the wireless motor For intruder detection to work, the lower stop must be recorded automatically with locks.
11.2 Defining the motor’s operating mode Alarm Stopping activation of the alarm The shutter remains in Mode 1 (default) The shutter closes position The shutter opens Mode 2 The shutter closes The shutter remains in The shutter remains in Mode 3 position position ❶...
12/ Your remote control is lost or not functioning These procedures are used to set the motor to Awaiting pairing mode for a new control unit (Tyxia 1701, 2331, TYDOM etc.) when the remote control of the relevant motor has been lost or is out of order. On the new remote control : - Press twice on button B located on the front panel of the remote control (or button T2 for the TYXIA 2331 wall-mounted remote control), , so that the LED...
14/ Troubleshooting • The motor does not work: - Check that the wiring corresponds to the diagrams in the «Connection» chapter. - Check that the motor is not in thermal protection mode; just wait a few minutes for it to cool down. - Check whether there is a problem linked to the end of travel settings and perform the reset again..