Summary of Contents for DELTA DORE TYMOOV RP Series
Page 1
TYMOOV radio xRP / DxRP / xRE Wireless Tubular Motor range...
Page 2
- TYMOOV xRP/DxRP or xRE motors are motors fitted with 868 place. MHz - X3D wireless receivers. They are compatible with the range of DELTA DORE X3D control systems and alarms. -TYMOOV xRP/DxRP or xRE motors are designed solely for the - Sufficiently rigid roller shutter blades should be used.
Page 3
- If an attempt is made to raise the shutter (for example: intruder test), the motor will lower the apron. Caution, your fingers may be caught. DELTA DORE hereby declares that the motorised systems covered by these instructions comply with the essential requirements set out by the Machinery Directive 2006/42/EC and the European directive RED 2014/53/EU.
Technical Characteristics Contents • Power supply: 230V - 50 Hz +/- 10% • Class II insulation 1/ Motor fitting ....................8 • Operating time: 4 minutes 1.1 Crown and wheel assembly ................. 8 • Electrical power : 1.2 Assembly in the tube ....................8 TYMOOV 10RP / RE / D10RP: 60 W 1.3 Motor head position ....................
1/ Motor fi tting • Never hit the motor head or output shaft to fi t the motor into the tube. 1.3 Motor head position Never pierce the tube when the motor is installed. The motor head must be positioned on the mount such that the cable outlet is in the •...
2/ Connection 3/ Starting up for the fi rst time The electrical wiring must comply with EN, IEC and national institute standards for The fi rst time it is switched on, the motor will make a short movement in both installation (e.g.: NF C15-100 for France).
3/ Starting up for the first time 3.2 Setting stops 3.2.1 Setting 2 automatic stops You can use Auto mode if there are both upper and lower physical stops. The motor will automatically detect its end of travel distances. If there are no upper physical stops and/or automatic locks, you must set the end of travel manually.
Page 8
3/ Starting up for the fi rst time 3.2.2 Setting 1 manual stop + 1 automatic stop 3.2.3 Setting 2 manual stops ❶ Position the shutter ❶ Position the shutter Scroll step by step Scroll step by step To scroll step by step, briefl y press then Press the button until the shutter is To scroll step by step, briefl y press then...
4/ Modifying stops 6/ Associating a smoke detector You want to control the opening of roller shutters if smoke is detected The stops must fi rst be removed then set again for them to be modifi ed. Remove them by proceeding as follows: On the transmitter that is already associated, press the button for more than 3 seconds...
8/ Remove one or several associations 9/ Obstacle detection The motors of the TYMOOV range include the obstacle detection feature. 8.1 Remove the remote control association with the After locking on an obstacle, the motor reverses direction by about 15 cm. motor Obstacles can only be detected when the stops have been set.
11/ Favourite positions 12/ Association with an alarm control unit This function is only available with the Radio Performance DxRP and xRP motors You can save up to 2 favourite positions: Not compatible with Radio Effi cacité RE motors. ❶ ❷ Set the shutter to the required position. In order for the intruder detector to function, the lower stop must automatically lock the shutter with fasteners.
12/ Association with an alarm control unit 13/ Your remote control is lost or not functioning 12.2 Defi ning the motor’s operating mode These procedures are used to set the motor to association wait mode for a new control unit (Tyxia 1703, 1712, TYDOM, etc.) when the remote control of the relevant motor has been lost or is out of order.
14/ Troubleshooting • If the motor is not working: - Check that the wiring corresponds to the diagrams in the “Connection” chapter. - Check the power supply in the network. - Check that the motor is not in thermal protection mode; just wait a few minutes for it to cool down.