Assa Abloy Corbin Russwin SN Series Installation Instructions Manual page 9

Exit device with melr
Hide thumbs Also See for Corbin Russwin SN Series:
Table of Contents

Advertisement

Installation Instructions
SN200/210 ED5000 Series Exit Device
With MELR
SN200 Wiegand Non-UL294 Configuration Application Diagram #2
Connect GREEN_LED input to switch controlled by panel. Shorting GREEN_LED to READER_NEG (Black) with panel switch
will override reader LED to keep it green.
Reader Electronics Requires 12VDC Filtered and Regulated
12/24VDC System
12 Conductor
ElectroLynx Harness
From McKinney
**IMPORTANT: Pin 7 - Brown and 4 - Tan must be tied to earth ground in the
access control panel.
Wiring in accordance with the NEC, ANSI/NFPA 70
Fail secure installations are subject to approval of local AHJ
Fail secure installations shall permit use of Listed panic
hardware to allow emergancy exit from the protected area.
Failure to follow proper ESD safe grounding procedures could
lead to equipment failure.
UL294 is a United States based standard.
Copyright © 2020-2023 ASSA ABLOY Access and Egress Hardware Group, Inc. All rights
reserved. Reproduction in whole or in part without the express written permission of
ASSA ABLOY Access and Egress Hardware Group, Inc. is prohibited.
5) Wiring Diagrams (Continued)
12V
Average
Reader*
75mA
Actuator (ET)
15mA
*Maximum AVG - RMS current draw during continuous card reads
Not evaluated by UL
Peak - highest instantaneous current draw during RF communication
QC12 Electric
Hinge From
McKinney
24V
Peak
Average
Peak
250mA
n/a
n/a
500mA
15mA
500mA
120 VAC
12-24VDC
Input
READER NEG - Black, 1
READER POS - Red, 2
DATA_1 - White, 3
DATA_0 - Green, 4
RX (NO) - Orange, 5
RX (COM) - Blue, 6
EARTH GROUND - Brown, 7
**
GREEN_LED - Yellow, 8
LOCK NEG - Violet, 9
LOCK POS - Gray, 10
DPS (NC) - Pink, 11
DPS (COM) - Tan, 12
9
H N G
Power Supply
12VDC
(By Others)
-
+
-
+
(-)
12VDC
(+)
DATA_1
DATA_0
RX (NO)
Use (NC) for
RX (COM)
Fail Safe
Operation
DPS
DPS
(NO) Fail
Secure
Operation
Panel Circuitry
(NC)
Panel Relay
(NO)
Electrical
Access
Control
Panel
(By Others)
Lock
Relay

Advertisement