Installation Instructions
SN200/210 ED5000 Series Exit Device
With MELR
12. Install Mounting Plate and (optional) Fire Plate:
a. NOTE: For fire-rated doors only. Secure mounting plate and fire plate using (2) #8 1-1/4" Phillips pan
head self-drilling screws provided (Fig. 12a). Ensure wires from reader are properly routed under flap
of fire plate.
b. Secure mounting plate using (2) remaining Phillips flat head self-drilling screws provided. Ensure
wires from reader are properly routed under flap of fire plate.
c. Place ground wire eyelet between upper right mounting plate hole and screw when securing mount-
ing plate (and fire plate if used) to door (Fig. 12a, b).
Configuration for Rim/CVR/Mortise
Configuration for SVR
Fig. 12c
Copyright © 2020-2023 ASSA ABLOY Access and Egress Hardware Group, Inc. All rights
reserved. Reproduction in whole or in part without the express written permission of
ASSA ABLOY Access and Egress Hardware Group, Inc. is prohibited.
6) Installation Instructions (Continued)
FIre
Plate
Ground
wire
Mounting
Screws
Fig. 12a
For non-fire rated door, use #8-5/8" Phillips pan
head screws (no fire plate required).
21
Ground
wire
Fig. 12b Detail