Specifications

■ ID Tags
Item
Memory capacity
128 bytes
Memory type
FeRAM
Memory life
Number of accesses: 1,000 million times (See note.)
Data storage time
10 years (after the data is written or read)
Ambient temperature Operating: −10 to 70°C
Ambient temperature Storage: −10 to 70°C
Ambient humidity
Operating: 35% to 95%
Degree of protection IEC 60529 IP67
Vibration resistance
10 to 2,000 Hz, 1.5-mm double amplitude at 150 m/s
each
Shock resistance
500 m/s
Material
PPS, filled with Epoxy resin
Weight
Approx. 1 g
Note: The number of accesses is the total number of read or write communications.
■ Antenna
Item
Oscillation frequency 13.56 MHz
Ambient temperature Operating: −10 to 70°C
Ambient temperature Storage: −25 to 75°C
Ambient humidity
Storage: 35% to 95%
Insulation resistance 20 MΩ min.
Dielectric strength
1,000 VAC for 1 minute between the terminals and case with a current leakage of 5 mA
Degree of protection IEC 60529 IP67 (See note 1.)
Vibration resistance
10 to 500 Hz, 1.5-mm double amplitude at 100 m/s
in X, Y, and Z directions for 11 minutes each
Shock resistance
300 m/s
Material
PBT/brass, filled with epoxy resin
Cable length
2 m (total length: 30 m (See note 2.))
Tightening torque
70 N·m
Approved standards FCC/R&TTE (CE)
Weight
140 g
Note: 1. The connector is not watertight.
2. The communications distance will be reduced if the cable is extended. The communications distance also depends on the type of exten-
sion cable used. Refer to Transmission Distance Specifications for details.
Model
V670-D13F01
2
in X, Y, and Z directions 3 times each (18 times in total)
V670-H51
2
in X, Y, and Z directions 3 times each (18 times in total)
Operation monitor, set value display, communica-
tions, test communications, and error log functions.
2 m
Connects the V670-CD1D and C200H-PRO27-E.
V670-D13F01H
2
acceleration with 10 sweeps in X, Y, and Z directions for 15 minutes
Approx. 1 g
V670-H51Q
IEC 60529 IP67
IP67g (transmission surface only, JEM
standard) (See note 1.)
2
acceleration with 10 sweeps
Fluororesin, filled with epoxy resin
2 N·m
130 g
Electromagnetic Inductive RFID System
Shape/Specification
V670-D13F03
Operating: 35% to 85%
ABS, filled with epoxy resin
Approx. 6 g
V670-H11
Storage: −25 to 85°C
Storage: 35% to 85%
IEC 60529 IP67 (See note 1.)
10 to 150 Hz, 0.7-mm double amplitude
2
at 50 m/s
acceleration with 10 sweeps
in X, Y, and Z directions for 8 minutes
each
ABS, filled with epoxy resin
---
Approx. 160 g