Transferring the System Program
Note
Transferring the system program from the system transfer tool
Reference
Operation
An NT11 which has no system program registered in it will be able to execute
only installation function.
For details on system transfer tool operations, refer to the NT-series Support
Tool Operation Manual (V061-E1-@).
In order to transfer the system program from the system transfer tool, first con-
nect the NT11 to a personal computer running the system transfer tool by
using the appropriate cable, then proceed as follows.
The NT11 uses one connector for the connection to both a PLC and a com-
puter. If it has been connected to a PLC, disconnect the PLC and connect the
system transfer tool (computer) to the NT11, and then, transmit the screen
data.
1. Connect the NT11 to the personal computer running the system transfer
tool, then switch on the power to the NT11.
2. Switch on the power to the personal computer and start up the system
transfer tool.
3. When the power to the NT11 is switched ON, the screen shown below is
displayed.
System Program
isn't installed.
Press ENTER key
to start install
4. Press the "ENTER" key to enter the system transfer mode, as shown be-
low.
[INSTALL MODE]
5. The NT11 is now on standby for reception. Start transfer of the program by
using the system transfer tool.
When the NT11 starts reception, the screen shown below is displayed.
[INSTALL MODE]
downloading...
6. When transfer of the system program is completed, the NT11 displays the
screen shown below.