Omron H7E Manual page 21

Self-powered totalizer h7e series
Hide thumbs Also See for H7E:
Table of Contents

Advertisement

■ Characteristics
Item
Insulation resistance
Dielectric strength
Impulse withstand voltage
Noise immunity
Static immunity
Vibration resistance
Shock resistance
EMC
Degree of protection
Weight (see note)
Note: Weight includes waterproof packing and flush mounting bracket.
■ Reference Value
Item
Battery life
7 years min. with continuous input at 25 C
(lithium battery)
H7ER-NV@-@
H7ER-NV@-@H
100 M min. (at 500 VDC) between current-carrying
metal parts and exposed non-current-carrying metal
parts, and between the backlight power supply and
count input terminals/reset terminals for backlight
models
1,000 VAC, 50/60 Hz for 1 min between current-car-
rying metal parts and exposed non-current-carrying
metal parts and between the backlight power supply
and count input terminals/reset terminals for back-
light models
4.5 kV between current-carrying terminal and exposed non-current-carrying metal parts
Square-wave noise generated by noise simulator (pulse width: 100 ns/1 s, 1-ns rise)
600 V (Between count input terminals)
480 V (Between the backlight power supply termi-
nals for backlight models)
8 kV (malfunction)
Malfunction: 0.15-mm single amplitude at 10 to 55 Hz for 10 min each in 3 directions
Destruction: 0.375-mm single amplitude at 10 to 55 Hz for 2 hrs each in 3 directions
2
Malfunction: 200 m/s
3 times each in 6 directions
Destruction: 300 m/s
2
3 times each in 6 directions
(EMI)
Emission Enclosure:
(EMS)
Immunity ESD:
Immunity RF-interference from AM Radio Waves:
Immunity RF-interference from Pulse-modulated Radio Waves:
Immunity Conducted Disturbance: EN61000-4-6: 10 V (0.15 to 80 MHz) (level 3)
Immunity Burst:
Front panel:
IP66, NEMA4 with waterproof packing
Terminal block: IP20
No-backlight model:Approx. 60 g
Backlight model:
Approx. 65 g
Value
The battery life is calculated according to the conditions in the left column and
therefore is not a guaranteed value. Use these value as reference for mainte-
nance or replacement.
100 M min. (at 500 VDC) between current-carrying
metal parts and exposed non-current-carrying metal
parts
1,000 VAC, 50/60 Hz for 1 min between current-car-
rying metal parts and exposed non-current-carrying
metal parts
500 V (Between count input terminals)
EN61326
EN55011 Group 1 class B
EN61326
EN61000-4-2: 4 kV contact discharge (level 2)
8 kV air discharge (level 3)
EN61000-4-3: 10 V/m (80 MHz to 1 GHz) (level 3)
EN61000-4-3: 10 V/m (900 MHz
EN61000-4-4: 2 kV power line (level 3)
2 kV I/O signal line (level 4)
Note
Self-powered Tachometer
H7ER-N-@
5 MHz) (level 3)
H7ER
C-27

Advertisement

Table of Contents
loading

Table of Contents